Reported Reactions

Devices › Applier, surgical, clip

Device brand name · Applier surgical clip

Ligaclip Applier W/Mech Stop: medical device reports filed with FDA

192 reports name it, 2005–2026. Manufacturer given most often on reports: Ethicon Endo-Surgery. Product code GDO.

192
device reports naming the brand
0% of all MAUDE reports · about 9 a year
18
reports, 12 months to August 2026
21 in the 12 months before
98.4%
classified as malfunction
91.5% across the product code
0%
classified as death, as reported
0 reports · not verified by FDA

FDA's MAUDE database holds 192 reports that name the brand "Ligaclip Applier W/Mech Stop" (applier surgical clip), received between May 2005 and February 2026; the manufacturer given most often on reports is Ethicon Endo-Surgery. Spellings of one product vary from report to report.

18 reports arrived in the 12 months to August 2026, down 14% from 21 in the 12 months before. FDA releases MAUDE data monthly; reports can arrive months after an event, so the newest months grow in later releases. The event types recorded are malfunction (98.4%) and injury (1.6%); across all applier, surgical, clip reports (product code GDO) death is recorded in 0.2% and malfunction in 91.5%. Event type is the reporter's classification of the report, not a verified outcome.

The device problems coded most often are failure to form staple (47.4%), failure to align (18.8%) and mechanical problem (9.4%). The patient problems coded most often are hemorrhage/blood loss/bleeding, no patient involvement and cardiac arrest. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data."

Reports by month, five years

0510Sep 2021: 1Oct 2021: 0Nov 2021: 0Dec 2021: 12022Jan 2022: 0Feb 2022: 0Mar 2022: 0Apr 2022: 0May 2022: 0Jun 2022: 2Jul 2022: 0Aug 2022: 1Sep 2022: 0Oct 2022: 3Nov 2022: 0Dec 2022: 02023Jan 2023: 0Feb 2023: 0Mar 2023: 1Apr 2023: 0May 2023: 1Jun 2023: 0Jul 2023: 2Aug 2023: 5Sep 2023: 1Oct 2023: 3Nov 2023: 4Dec 2023: 42024Jan 2024: 0Feb 2024: 0Mar 2024: 10Apr 2024: 3May 2024: 0Jun 2024: 0Jul 2024: 2Aug 2024: 1Sep 2024: 0Oct 2024: 1Nov 2024: 2Dec 2024: 02025Jan 2025: 0Feb 2025: 0Mar 2025: 3Apr 2025: 1May 2025: 0Jun 2025: 2Jul 2025: 2Aug 2025: 10Sep 2025: 6Oct 2025: 3Nov 2025: 0Dec 2025: 12026Jan 2026: 3Feb 2026: 5Mar 2026: 0Apr 2026: 0May 2026: 0Jun 2026: 0Jul 2026: 0Aug 2026: 0

Reports by the month FDA received them. FDA releases MAUDE data monthly; reports can arrive months after an event, so the newest months grow in later releases.

By year received

028562005: 320052018: 5620182019: 3520192020: 1220202021: 420212022: 620222023: 2120232024: 1920242025: 2820252026: 82026

Event type and report source

Event type, as classified on the report

Death0%0
Injury1.6%3
Malfunction98.4%189
Other0%0
Not given0%0

Who filed the report

Manufacturer report100%192
Voluntary report0%0
User facility report0%0
Distributor report0%0
Not given0%0

Grey bar: all 16,592 reports carrying product code GDO. Event type is the filer's classification and is not verified by FDA.

Device problems coded

Device problem (FDA code)ReportsShareShare across product code
Failure to form staple9147.4%26.8%
Failure to align3618.8%3.7%
Mechanical problema mechanical problem189.4%1.4%
Difficult to open or close105.2%2.3%
Unintended ejection94.7%0.5%
Detachment of device or device componentpart of the device came off52.6%1.2%
Breakthe device broke42.1%5%
Defective devicethe device was defective42.1%0.3%
Detachment of device component42.1%2.3%
Device fell42.1%0.1%
Material twisted/bent42.1%0.6%
Bent31.6%0.4%
Corrodedthe device corroded31.6%0%
Crackthe device cracked31.6%0.1%
Insufficient device problem information31.6%0.3%
Material integrity problema problem with the device material31.6%0.2%
Activation, positioning or separation problem21%0.8%
Application program problem10.5%0%
Defective component10.5%0.1%
Degraded10.5%0%

FDA's device problem codes as entered on the report; one report can carry several. Generic codes such as "no apparent adverse event" are left out.

Patient problems coded

Patient problem (FDA code)ReportsShare
Hemorrhage/blood loss/bleeding147.3%
No patient involvement63.1%
Cardiac arrestthe heart stopped21%
Failure to anastomose10.5%
Tissue damage10.5%

Patient problem codes are present mainly in reports filed since 2019 and are often blank.

In context

MeasureLigaclip Applier W/Mech StopProduct code GDOAll MAUDE reports
Reports19216,59226,136,888
Share of that pool—1.2%0%
Classified as death, per 1,000 reports029
Classified as injury1.6%6.5%36.2%
Classified as malfunction98.4%91.5%62.3%
Filed by the manufacturer100%93.3%94.9%

Shares are of reports, not of devices in use. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data."

Other brands with product code GDO

BrandReportsLatest 12 monthsClassified as death
Ligaclip Endoscopic Rotating Multiple Clip Applier4,35100.1%
Ligaclip Multiple Clip Applier1,06900.2%
Weck Hol Ml 5mm Endo Applier5783060%
Ligaclip Mca Small Applier557190.2%
Ligaclip Endoscopic Multiple Clip Applier56000%
Ligaclip Endoscopic Rotating Multiple Clip Applier 2082100%
Ligaclip Mca Med Applier51340.4%
Hol Ml 5mm Endo Applier45700%
Ligaclip Rotating Multiple Clip Applier46300%
Ligaclip Endo Rotating Mca2,2091090%
Ligaclip Mca Med Long Applier40890.2%
Ligaclip Clip Applier1,78700%
Ligaclip1,4253080%
Resolution Clip Device1,59600.3%
Ligaclip Mca Large Applier26830.4%

Ordered by report count for navigation only. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data." FDA also states that "common products may have a higher number of adverse events due to the higher total number of people using the product."

Questions about Ligaclip Applier W/Mech Stop reports

How many FDA reports name Ligaclip Applier W/Mech Stop?

192 medical device reports in the openFDA MAUDE release of 28 Sep 2026, covering reports received through August 2026; 18 in the latest 12 months.

What kinds of events are reported?

malfunction (98.4%) and injury (1.6%). "Event type" is how the report was classified when filed: death, injury, malfunction or other.

What device problems are coded?

failure to form staple (47.4%), failure to align (18.8%), mechanical problem (9.4%), difficult to open or close (5.2%) and unintended ejection (4.7%). These are FDA's device problem codes as entered on the report.

Who files these reports?

manufacturer reports (100%). Manufacturers and user facilities are required to report; voluntary reports come from health professionals and the public.

Do these reports show that Ligaclip Applier W/Mech Stop was at fault?

No. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data." FDA adds that "a causal relationship cannot be established between product and reactions listed in a report."

How do I report a problem with a medical device?

Through FDA MedWatch (Form FDA 3500 for health professionals and consumers), or to the manufacturer. See the guide on how to report.

Where this comes from. Counts are built from the openFDA Device Adverse Event (MAUDE) bulk export released 28 Sep 2026, which holds reports FDA received through 31 Aug 2026. Brand, generic and manufacturer names are as written on the reports; product code names come from FDA's device classification. A report counts here when any device it lists carries this brand name after punctuation and capitalisation are normalised. No report narrative, lot number, patient detail or reporter identity is published. See the methodology and sources; FDA's record is authoritative, and corrections are handled within five working days.

Drug data (FAERS) through 30 Jun 2026; device data (MAUDE) through 31 Aug 2026. Not medical advice.