Reported Reactions

Devices › Prosthesis, tracheal, expandable

Device brand name · Tracheobronchial stent graft

Fluency Plus Tracheobronchial Stent Graft: medical device reports filed with FDA

323 reports name it, 2006–2016. Manufacturer given most often on reports: Angiomed & Medizinte. Product code JCT.

323
device reports naming the brand
0% of all MAUDE reports · about 16 a year
0
reports, 12 months to August 2026
0 in the 12 months before
90.7%
classified as malfunction
52.9% across the product code
0%
classified as death, as reported
0 reports · not verified by FDA

FDA's MAUDE database holds 323 reports that name the brand "Fluency Plus Tracheobronchial Stent Graft" (tracheobronchial stent graft), received between January 2006 and June 2016; the manufacturer given most often on reports is Angiomed & Medizinte. Spellings of one product vary from report to report.

0 reports arrived in the 12 months to August 2026, and none in the 12 months before. FDA releases MAUDE data monthly; reports can arrive months after an event, so the newest months grow in later releases. The event types recorded are malfunction (90.7%) and injury (9.3%); across all prosthesis, tracheal, expandable reports (product code JCT) death is recorded in 3.6% and malfunction in 52.9%. Event type is the reporter's classification of the report, not a verified outcome.

The device problems coded most often are positioning failure (44.9%), fracture (28.2%) and replace (11.1%). The patient problems coded most often are foreign body, removal of, therapy/non-surgical treatment, additional and bleeding. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data."

Reports by month, five years

No report naming Fluency Plus Tracheobronchial Stent Graft was received in the five years to August 2026; the latest was received in June 2016.

By year received

046912006: 7120062007: 912008: 7820082009: 172010: 1320102011: 32012: 2820122013: 32014: 520142015: 112016: 32016

Event type and report source

Event type, as classified on the report

Death0%0
Injury9.3%30
Malfunction90.7%293
Other0%0
Not given0%0

Who filed the report

Manufacturer report100%323
Voluntary report0%0
User facility report0%0
Distributor report0%0
Not given0%0

Grey bar: all 3,011 reports carrying product code JCT. Event type is the filer's classification and is not verified by FDA.

Device problems coded

Device problem (FDA code)ReportsShareShare across product code
Positioning failure14544.9%13.4%
Fracturea broken bone9128.2%5.9%
Replace3611.1%4.6%
Detachment of device component299%5.3%
Device, removal of (non-implant)299%2%
Difficult or delayed positioning257.7%3.7%
Physical resistance185.6%1.8%
Breakthe device broke154.6%7.8%
Sticking144.3%2.1%
Material separation123.7%2.2%
Component(s), broken113.4%1.6%
Failure to advance113.4%2.1%
Device remains implanted103.1%2.4%
Bent72.2%0.8%
Difficult to removethe device was hard to remove72.2%4.6%
Difficult to insertthe device was hard to insert61.9%0.9%
Explanted51.5%2.2%
Fitting problem41.2%0.4%
Migration or expulsion of device41.2%3.8%
Kinkedthe tube or line kinked30.9%0.9%

FDA's device problem codes as entered on the report; one report can carry several. Generic codes such as "no apparent adverse event" are left out.

Patient problems coded

Patient problem (FDA code)ReportsShare
Foreign body, removal of154.6%
Therapy/non-surgical treatment, additional113.4%
Bleeding61.9%
Nonresorbable materials, unretrieved in body51.5%
Surgery, prolonged30.9%
Surgical procedure30.9%
Blood loss20.6%
Dural tear20.6%
Hematomaa collection of blood under the skin or in tissue20.6%
Intimal dissection20.6%
Occlusion20.6%
Surgical incision, enlargement of20.6%
Blockage10.3%
Deaththe patient died; cause not stated by this term10.3%
Device embedded in tissue or plaque10.3%

Patient problem codes are present mainly in reports filed since 2019 and are often blank.

In context

MeasureFluency Plus Tracheobronchial Stent GraftProduct code JCTAll MAUDE reports
Reports3233,01126,136,888
Share of that pool—10.7%0%
Classified as death, per 1,000 reports0369
Classified as injury9.3%42.3%36.2%
Classified as malfunction90.7%52.9%62.3%
Filed by the manufacturer100%95.7%94.9%

Shares are of reports, not of devices in use. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data."

Other brands with product code JCT

BrandReportsLatest 12 monthsClassified as death
Ultraflex Tracheobronchial713510.3%
Icast Covered Stent24509.8%
Atrium Icast Covered Stent20800.5%
WALLSTENT Endoprosthesis364141.4%
GORE VIABAHN Endoprosthesis985185.8%
Ultraflex19804.5%
Wallstent Enteral Endoprosthesis162010.5%
Wallstent Biliary16150.6%
Advanta V12 Covered Stent340012.6%
Wallstent Endoprosthesis With Unistep Plus Delivery System20602.9%
Wallstent Rx Biliary Endoprosthesis18700.5%

Ordered by report count for navigation only. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data." FDA also states that "common products may have a higher number of adverse events due to the higher total number of people using the product."

Questions about Fluency Plus Tracheobronchial Stent Graft reports

How many FDA reports name Fluency Plus Tracheobronchial Stent Graft?

323 medical device reports in the openFDA MAUDE release of 28 Sep 2026, covering reports received through August 2026; 0 in the latest 12 months.

What kinds of events are reported?

malfunction (90.7%) and injury (9.3%). "Event type" is how the report was classified when filed: death, injury, malfunction or other.

What device problems are coded?

positioning failure (44.9%), fracture (28.2%), replace (11.1%), detachment of device component (9%) and device, removal of (non-implant) (9%). These are FDA's device problem codes as entered on the report.

Who files these reports?

manufacturer reports (100%). Manufacturers and user facilities are required to report; voluntary reports come from health professionals and the public.

Do these reports show that Fluency Plus Tracheobronchial Stent Graft was at fault?

No. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data." FDA adds that "a causal relationship cannot be established between product and reactions listed in a report."

How do I report a problem with a medical device?

Through FDA MedWatch (Form FDA 3500 for health professionals and consumers), or to the manufacturer. See the guide on how to report.

Where this comes from. Counts are built from the openFDA Device Adverse Event (MAUDE) bulk export released 28 Sep 2026, which holds reports FDA received through 31 Aug 2026. Brand, generic and manufacturer names are as written on the reports; product code names come from FDA's device classification. A report counts here when any device it lists carries this brand name after punctuation and capitalisation are normalised. No report narrative, lot number, patient detail or reporter identity is published. See the methodology and sources; FDA's record is authoritative, and corrections are handled within five working days.

Drug data (FAERS) through 30 Jun 2026; device data (MAUDE) through 31 Aug 2026. Not medical advice.