Unknown Endo Gia: medical device reports filed with FDA

247 reports name it, 2017–2020. Manufacturer given most often on reports: US Surgical Puerto Rico. Product code GDW.

247
device reports naming the brand
0% of all MAUDE reports · about 28 a year
0
reports, 12 months to August 2026
0 in the 12 months before
85.4%
classified as malfunction
80.3% across the product code
0.8%
classified as death, as reported
2 reports · not verified by FDA

247 medical device reports received by FDA name the brand "Unknown Endo Gia" (staple implantable); the manufacturer given most often on reports is US Surgical Puerto Rico; received from September 2017 to July 2020. Brand names are as the reporter or manufacturer wrote them, so one product can appear under several spellings.

0 reports arrived in the 12 months to August 2026, and none in the 12 months before. FDA releases MAUDE data monthly; reports can arrive months after an event, so the newest months grow in later releases. The event types recorded are malfunction (85.4%), injury (13.8%) and death (0.8%); across all staple, implantable reports (product code GDW) death is recorded in 0.6% and malfunction in 80.3%. Event type is the reporter's classification of the report, not a verified outcome.

The device problems coded most often are failure to fire (60.7%), misfire (13.4%) and difficult to open or close (8.9%). The patient problems coded most often are no patient involvement, fistula and tissue damage. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data."

Reports by month, five years

No report naming Unknown Endo Gia was received in the five years to August 2026; the latest was received in July 2020.

By year received

0721432017: 4920172018: 3520182019: 14320192020: 202020

Event type and report source

Event type, as classified on the report

Death0.8%2
Injury13.8%34
Malfunction85.4%211
Other0%0
Not given0%0

Who filed the report

Manufacturer report98.8%244
Voluntary report0%0
User facility report0%0
Distributor report0%0
Not given1.2%3

Grey bar: all 170,752 reports carrying product code GDW. Event type is the filer's classification and is not verified by FDA.

Device problems coded

Device problem (FDA code)ReportsShareShare across product code
Failure to fire15060.7%30%
Misfire3313.4%9.1%
Difficult to open or close228.9%9.7%
Failure to form staple197.7%20.5%
Human-device interface problem93.6%2.4%
Entrapment of device83.2%3.2%
Breakthe device broke62.4%4.9%
Mechanics altered41.6%1.4%
Component or accessory incompatibility31.2%0.7%
Difficult or delayed positioning20.8%0.3%
Noise, audible20.8%2.3%
Difficult to position10.4%0.1%
Difficult to removethe device was hard to remove10.4%1.7%
Fail-safe problem10.4%0.1%
Firing problem10.4%1.6%
Fluid/blood leak10.4%0.3%
Physical resistance/sticking10.4%0.3%
Positioning problem10.4%0.3%
Retraction problem10.4%1.2%
Unintended movement10.4%0.3%

FDA's device problem codes as entered on the report; one report can carry several. Generic codes such as "no apparent adverse event" are left out.

Patient problems coded

Patient problem (FDA code)ReportsShare
No patient involvement72.8%
Fistula52%
Tissue damage52%
Blood loss31.2%
Injurya physical injury31.2%
Deaththe patient died; cause not stated by this term20.8%
Hemorrhage/blood loss/bleeding20.8%
Obstruction/occlusion20.8%
Abdominal painstomach or belly pain10.4%
Abscessa collection of pus10.4%
Ascitesfluid in the abdomen10.4%
Encephalopathy10.4%
Exsanguination10.4%
Failure to anastomose10.4%
Fever10.4%

Patient problem codes are present mainly in reports filed since 2019 and are often blank.

In context

MeasureUnknown Endo GiaProduct code GDWAll MAUDE reports
Reports247170,75226,136,888
Share of that pool—0.1%0%
Classified as death, per 1,000 reports869
Classified as injury13.8%18.7%36.2%
Classified as malfunction85.4%80.3%62.3%
Filed by the manufacturer98.8%97%94.9%

Shares are of reports, not of devices in use. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data."

Other brands with product code GDW

BrandReportsLatest 12 monthsClassified as death
Endo GIA30,6192,0860.3%
Endo GIA Ultra17,2811,1160.1%
Signia9,4341,1300.1%
Tri-Staple 2.05,2676610.3%
Gia4,8994040.9%
Eea4,9225420.8%
Powered 60 Echelon + 340mm Shaft3,2372240.4%
Ets Flex Articng Lnr Cutr 45mm2,512790.3%
Unknown Endo GIA SULU2,4082051.9%
SureForm2,9276541.2%
Contour Curved Cutter Stapler1,961110.3%
Ils 29mm Curved1,945480.9%
Powered 60 Echelon + 440mm Shaft1,775490.4%
Echelon Flex Powered Vascular Stapler With Advanced Placement Tip1,7701801.6%
75mm Selectable New Tlc1,603571.1%

Ordered by report count for navigation only. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data." FDA also states that "common products may have a higher number of adverse events due to the higher total number of people using the product."

Questions about Unknown Endo Gia reports

How many FDA reports name Unknown Endo Gia?

247 medical device reports in the openFDA MAUDE release of 28 Sep 2026, covering reports received through August 2026; 0 in the latest 12 months.

What kinds of events are reported?

malfunction (85.4%), injury (13.8%) and death (0.8%). "Event type" is how the report was classified when filed: death, injury, malfunction or other.

What device problems are coded?

failure to fire (60.7%), misfire (13.4%), difficult to open or close (8.9%), failure to form staple (7.7%) and human-device interface problem (3.6%). These are FDA's device problem codes as entered on the report.

Who files these reports?

manufacturer reports (98.8%). Manufacturers and user facilities are required to report; voluntary reports come from health professionals and the public.

Do these reports show that Unknown Endo Gia was at fault?

No. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data." FDA adds that "a causal relationship cannot be established between product and reactions listed in a report."

How do I report a problem with a medical device?

Through FDA MedWatch (Form FDA 3500 for health professionals and consumers), or to the manufacturer. See the guide on how to report.

Where this comes from. Counts are built from the openFDA Device Adverse Event (MAUDE) bulk export released 28 Sep 2026, which holds reports FDA received through 31 Aug 2026. Brand, generic and manufacturer names are as written on the reports; product code names come from FDA's device classification. A report counts here when any device it lists carries this brand name after punctuation and capitalisation are normalised. No report narrative, lot number, patient detail or reporter identity is published. See the methodology and sources; FDA's record is authoritative, and corrections are handled within five working days.