1,579
device reports naming the brand
0% of all MAUDE reports · about 72 a year
0
reports, 12 months to August 2026
0 in the 12 months before
90.9%
classified as malfunction
85.5% across the product code
1.1%
classified as death, as reported
17 reports · not verified by FDA

FDA's MAUDE database holds 1,579 reports that name the brand "Maverick2 Monorail Ptca Catheter" (lox catheters transluminal coronary angioplasty percutaneous), received between September 2004 and July 2010; the manufacturer given most often on reports is Boston Scientific. Spellings of one product vary from report to report.

0 reports arrived in the 12 months to August 2026, and none in the 12 months before. FDA releases MAUDE data monthly; reports can arrive months after an event, so the newest months grow in later releases. The event types recorded are malfunction (90.9%), injury (7.9%) and death (1.1%); across all catheters, transluminal coronary angioplasty, percutaneous reports (product code LOX) death is recorded in 1.3% and malfunction in 85.5%. Event type is the reporter's classification of the report, not a verified outcome.

The device problems coded most often are balloon rupture (67.1%), replace (31.3%) and shaft break (8.9%). The patient problems coded most often are intimal dissection, surgical procedure, additional and no patient involvement. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data."

Reports by month, five years

No report naming Maverick2 Monorail Ptca Catheter was received in the five years to August 2026; the latest was received in July 2010.

By year received

02164312004: 520042005: 26820052006: 37320062007: 43120072008: 26820082009: 21320092010: 212010

Event type and report source

Event type, as classified on the report

Death1.1%17
Injury7.9%124
Malfunction90.9%1,436
Other0.1%1
Not given0.1%1

Who filed the report

Manufacturer report100%1,579
Voluntary report0%0
User facility report0%0
Distributor report0%0
Not given0%0

Grey bar: all 43,618 reports carrying product code LOX. Event type is the filer's classification and is not verified by FDA.

Device problems coded

Device problem (FDA code)ReportsShareShare across product code
Balloon rupture1,06067.1%10.2%
Replace49431.3%4.8%
Shaft break1418.9%1.9%
Inflation problem1268%5.6%
Device, removal of (non-implant)1207.6%2.2%
Failure to advance684.3%5.4%
Difficult to removethe device was hard to remove573.6%11.3%
Deflation problem563.5%5.9%
Balloon burst483%1.2%
Kinkedthe tube or line kinked362.3%1.8%
Difficult to insertthe device was hard to insert312%1.2%
Physical resistance221.4%2.3%
Sticking221.4%0.7%
Other (for use when an appropriate device code cannot be identified)211.3%0.3%
Tears, rips, holes in device, device material211.3%0.2%
Balloon pinhole171.1%0.1%
Breakthe device broke171.1%7.4%
Detachment of device component171.1%4.3%
Device damaged prior to usethe device was damaged before use171.1%0.7%
Device, or device fragments remain in patient100.6%0.5%

FDA's device problem codes as entered on the report; one report can carry several. Generic codes such as "no apparent adverse event" are left out.

Patient problems coded

Patient problem (FDA code)ReportsShare
Intimal dissection704.4%
Surgical procedure, additional563.5%
No patient involvement402.5%
Deaththe patient died; cause not stated by this term171.1%
Foreign body, removal of150.9%
Therapy/non-surgical treatment, additional130.8%
Nonresorbable materials, unretrieved in body110.7%
Surgical procedure100.6%
Asystole80.5%
Occlusion70.4%
Calcium deposits/calcification60.4%
Cardiac arrestthe heart stopped60.4%
Chest painchest pain60.4%
St segment elevation60.4%
Surgery, prolonged60.4%

Patient problem codes are present mainly in reports filed since 2019 and are often blank.

In context

MeasureMaverick2 Monorail Ptca CatheterProduct code LOXAll MAUDE reports
Reports1,57943,61826,136,888
Share of that pool—3.6%0%
Classified as death, per 1,000 reports11139
Classified as injury7.9%12.9%36.2%
Classified as malfunction90.9%85.5%62.3%
Filed by the manufacturer100%97.7%94.9%

Shares are of reports, not of devices in use. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data."

Other brands with product code LOX

BrandReportsLatest 12 monthsClassified as death
NC Emerge5,6905431.4%
Nc Trek Coronary Dilatation Catheter4,68900.5%
Emerge3,7241681.8%
NC Quantum Apex?2,518300.8%
Trek Coronary Dilatation Catheter2,20431.1%
Mini Trek Coronary Dilatation Catheter1,53800.5%
Maverick?1,337710.4%
Ptca Catheters1,26900.4%
Quantum? Maverick?1,173390.3%
Voyager Nc Coronary Dilatation Catheter74700.5%
Apex Monorail60301.7%
Euphora Rx529431.7%
Voyager Rx Coronary Dilatation Catheter73600.7%
Apex876781.3%
Nc Traveler Coronary Dilatation Catheter50400.6%

Ordered by report count for navigation only. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data." FDA also states that "common products may have a higher number of adverse events due to the higher total number of people using the product."

Questions about Maverick2 Monorail Ptca Catheter reports

How many FDA reports name Maverick2 Monorail Ptca Catheter?

1,579 medical device reports in the openFDA MAUDE release of 28 Sep 2026, covering reports received through August 2026; 0 in the latest 12 months.

What kinds of events are reported?

malfunction (90.9%), injury (7.9%) and death (1.1%). "Event type" is how the report was classified when filed: death, injury, malfunction or other.

What device problems are coded?

balloon rupture (67.1%), replace (31.3%), shaft break (8.9%), inflation problem (8%) and device, removal of (non-implant) (7.6%). These are FDA's device problem codes as entered on the report.

Who files these reports?

manufacturer reports (100%). Manufacturers and user facilities are required to report; voluntary reports come from health professionals and the public.

Do these reports show that Maverick2 Monorail Ptca Catheter was at fault?

No. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data." FDA adds that "a causal relationship cannot be established between product and reactions listed in a report."

How do I report a problem with a medical device?

Through FDA MedWatch (Form FDA 3500 for health professionals and consumers), or to the manufacturer. See the guide on how to report.

Where this comes from. Counts are built from the openFDA Device Adverse Event (MAUDE) bulk export released 28 Sep 2026, which holds reports FDA received through 31 Aug 2026. Brand, generic and manufacturer names are as written on the reports; product code names come from FDA's device classification. A report counts here when any device it lists carries this brand name after punctuation and capitalisation are normalised. No report narrative, lot number, patient detail or reporter identity is published. See the methodology and sources; FDA's record is authoritative, and corrections are handled within five working days.

Drug data (FAERS) through 30 Jun 2026; device data (MAUDE) through 31 Aug 2026. Not medical advice.