Reported Reactions

Devices › Catheters, transluminal coronary angioplasty, percutaneous

Device brand name · Ptca balloon catheters lox

Fire Star Rx Ptca Balloon Catheter: medical device reports filed with FDA

291 reports name it, 2007–2015. Manufacturer given most often on reports: Cordis De Mexico. Product code LOX.

291
device reports naming the brand
0% of all MAUDE reports · about 15 a year
0
reports, 12 months to August 2026
0 in the 12 months before
92.8%
classified as malfunction
85.5% across the product code
0%
classified as death, as reported
0 reports · not verified by FDA

FDA's MAUDE database holds 291 reports that name the brand "Fire Star Rx Ptca Balloon Catheter" (ptca balloon catheters lox), received between May 2007 and April 2015; the manufacturer given most often on reports is Cordis De Mexico. Spellings of one product vary from report to report.

0 reports arrived in the 12 months to August 2026, and none in the 12 months before. FDA releases MAUDE data monthly; reports can arrive months after an event, so the newest months grow in later releases. The event types recorded are malfunction (92.8%), injury (6.5%) and other (0.7%); across all catheters, transluminal coronary angioplasty, percutaneous reports (product code LOX) death is recorded in 1.3% and malfunction in 85.5%. Event type is the reporter's classification of the report, not a verified outcome.

The device problems coded most often are deflation problem (31.3%), device contamination with chemical or other material (12.7%) and burst container or vessel (10.7%). The patient problems coded most often are chest pain, intimal dissection and therapy/non-surgical treatment, additional. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data."

Reports by month, five years

No report naming Fire Star Rx Ptca Balloon Catheter was received in the five years to August 2026; the latest was received in April 2015.

By year received

0551092007: 2520072008: 4320082009: 10920092010: 4520102011: 2420112012: 2220122013: 520132014: 1320142015: 52015

Event type and report source

Event type, as classified on the report

Death0%0
Injury6.5%19
Malfunction92.8%270
Other0.7%2
Not given0%0

Who filed the report

Manufacturer report100%291
Voluntary report0%0
User facility report0%0
Distributor report0%0
Not given0%0

Grey bar: all 43,618 reports carrying product code LOX. Event type is the filer's classification and is not verified by FDA.

Device problems coded

Device problem (FDA code)ReportsShareShare across product code
Deflation problem9131.3%5.9%
Device contamination with chemical or other material3712.7%0.3%
Burst container or vessel3110.7%2.2%
Balloon burst3010.3%1.2%
Packaging problem2910%0.2%
Inflation problem206.9%5.6%
Difficult to removethe device was hard to remove175.8%11.3%
Leak/splashthe device leaked144.8%2.5%
Balloon rupture93.1%10.2%
Material separation93.1%3%
Foreign material82.7%0.1%
Balloon leak(s)51.7%0.3%
Crackthe device cracked51.7%0.1%
Detachment of device component51.7%4.3%
Device packaging compromised51.7%0%
Unsealed device packaging41.4%0.2%
Delivered as unsterile product31%0%
Breakthe device broke20.7%7.4%
Inadequacy of device shape and/or size20.7%0.1%
Device disinfection or sterilization issue10.3%0%

FDA's device problem codes as entered on the report; one report can carry several. Generic codes such as "no apparent adverse event" are left out.

Patient problems coded

Patient problem (FDA code)ReportsShare
Chest painchest pain62.1%
Intimal dissection51.7%
Therapy/non-surgical treatment, additional51.7%
Myocardial infarctionheart attack41.4%
No patient involvement31%
Other (for use when an appropriate patient code cannot be identified)31%
Ischemia20.7%
St segment elevation20.7%
Arrhythmia10.3%
Blood pressure, decreased10.3%
Bradycardiaslow heart rate10.3%
Cardiac enzyme elevation10.3%
Complete heart block10.3%
Diminished pulse pressure10.3%
Foreign body, removal of10.3%

Patient problem codes are present mainly in reports filed since 2019 and are often blank.

In context

MeasureFire Star Rx Ptca Balloon CatheterProduct code LOXAll MAUDE reports
Reports29143,61826,136,888
Share of that pool—0.7%0%
Classified as death, per 1,000 reports0139
Classified as injury6.5%12.9%36.2%
Classified as malfunction92.8%85.5%62.3%
Filed by the manufacturer100%97.7%94.9%

Shares are of reports, not of devices in use. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data."

Other brands with product code LOX

BrandReportsLatest 12 monthsClassified as death
NC Emerge5,6905431.4%
Nc Trek Coronary Dilatation Catheter4,68900.5%
Emerge3,7241681.8%
NC Quantum Apex?2,518300.8%
Trek Coronary Dilatation Catheter2,20431.1%
Maverick2 Monorail Ptca Catheter1,57901.1%
Mini Trek Coronary Dilatation Catheter1,53800.5%
Maverick?1,337710.4%
Ptca Catheters1,26900.4%
Quantum? Maverick?1,173390.3%
Voyager Nc Coronary Dilatation Catheter74700.5%
Apex Monorail60301.7%
Euphora Rx529431.7%
Voyager Rx Coronary Dilatation Catheter73600.7%
Apex876781.3%

Ordered by report count for navigation only. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data." FDA also states that "common products may have a higher number of adverse events due to the higher total number of people using the product."

Questions about Fire Star Rx Ptca Balloon Catheter reports

How many FDA reports name Fire Star Rx Ptca Balloon Catheter?

291 medical device reports in the openFDA MAUDE release of 28 Sep 2026, covering reports received through August 2026; 0 in the latest 12 months.

What kinds of events are reported?

malfunction (92.8%), injury (6.5%) and other (0.7%). "Event type" is how the report was classified when filed: death, injury, malfunction or other.

What device problems are coded?

deflation problem (31.3%), device contamination with chemical or other material (12.7%), burst container or vessel (10.7%), balloon burst (10.3%) and packaging problem (10%). These are FDA's device problem codes as entered on the report.

Who files these reports?

manufacturer reports (100%). Manufacturers and user facilities are required to report; voluntary reports come from health professionals and the public.

Do these reports show that Fire Star Rx Ptca Balloon Catheter was at fault?

No. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data." FDA adds that "a causal relationship cannot be established between product and reactions listed in a report."

How do I report a problem with a medical device?

Through FDA MedWatch (Form FDA 3500 for health professionals and consumers), or to the manufacturer. See the guide on how to report.

Where this comes from. Counts are built from the openFDA Device Adverse Event (MAUDE) bulk export released 28 Sep 2026, which holds reports FDA received through 31 Aug 2026. Brand, generic and manufacturer names are as written on the reports; product code names come from FDA's device classification. A report counts here when any device it lists carries this brand name after punctuation and capitalisation are normalised. No report narrative, lot number, patient detail or reporter identity is published. See the methodology and sources; FDA's record is authoritative, and corrections are handled within five working days.

Drug data (FAERS) through 30 Jun 2026; device data (MAUDE) through 31 Aug 2026. Not medical advice.