Reported Reactions

Devices › Stent, coronary

Device brand name · Maf stent coronary

Liberte Monorail Coronary Stent Delivery System: medical device reports filed with FDA

194 reports name it, 2006–2009. Manufacturer given most often on reports: Boston Scientific. Product code MAF.

194
device reports naming the brand
0% of all MAUDE reports · about 10 a year
0
reports, 12 months to August 2026
0 in the 12 months before
67%
classified as malfunction
40.4% across the product code
3.6%
classified as death, as reported
7 reports · not verified by FDA

FDA's MAUDE database holds 194 reports that name the brand "Liberte Monorail Coronary Stent Delivery System" (maf stent coronary), received between September 2006 and November 2009; the manufacturer given most often on reports is Boston Scientific. Spellings of one product vary from report to report.

0 reports arrived in the 12 months to August 2026, and none in the 12 months before. FDA releases MAUDE data monthly; reports can arrive months after an event, so the newest months grow in later releases. The event types recorded are malfunction (67%), injury (29.4%) and death (3.6%); across all stent, coronary reports (product code MAF) death is recorded in 7.6% and malfunction in 40.4%. Event type is the reporter's classification of the report, not a verified outcome.

The device problems coded most often are device damaged prior to use (32.5%), dislodged (25.8%) and device remains implanted (21.6%). The patient problems coded most often are no patient involvement, surgical procedure, additional and myocardial infarction. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data."

Reports by month, five years

No report naming Liberte Monorail Coronary Stent Delivery System was received in the five years to August 2026; the latest was received in November 2009.

By year received

0521032006: 720062007: 10320072008: 5220082009: 322009

Event type and report source

Event type, as classified on the report

Death3.6%7
Injury29.4%57
Malfunction67%130
Other0%0
Not given0%0

Who filed the report

Manufacturer report99.5%193
Voluntary report0%0
User facility report0%0
Distributor report0%0
Not given0.5%1

Grey bar: all 23,279 reports carrying product code MAF. Event type is the filer's classification and is not verified by FDA.

Device problems coded

Device problem (FDA code)ReportsShareShare across product code
Device damaged prior to usethe device was damaged before use6332.5%3.8%
Dislodged5025.8%15.9%
Device remains implanted4221.6%6.3%
Failure to advance3719.1%20.9%
Replace2613.4%7.5%
Shaft break2110.8%1.5%
Difficult to removethe device was hard to remove147.2%10.2%
Occlusion within devicethe device blocked126.2%4.7%
Device, or device fragments remain in patient73.6%3.4%
Device, removal of (non-implant)52.6%2.4%
Difficult to insertthe device was hard to insert52.6%6.7%
Failure to deliverthe device did not deliver the dose or item52.6%0.3%
Deflation problem42.1%2.2%
Loose42.1%1%
Sticking42.1%2.1%
Kinkedthe tube or line kinked31.5%1.1%
Migration or expulsion of device31.5%2.5%
Out-of-box failure31.5%0.3%
Positioning failure31.5%2.8%
Balloon rupture21%4.3%

FDA's device problem codes as entered on the report; one report can carry several. Generic codes such as "no apparent adverse event" are left out.

Patient problems coded

Patient problem (FDA code)ReportsShare
No patient involvement4422.7%
Surgical procedure, additional3216.5%
Myocardial infarctionheart attack126.2%
Thrombosis126.2%
Intimal dissection115.7%
Nonresorbable materials, unretrieved in body105.2%
Foreign body, removal of73.6%
Deaththe patient died; cause not stated by this term63.1%
Chest painchest pain42.1%
Hospitalization required31.5%
Reocclusion31.5%
Surgery, prolonged31.5%
Therapy/non-surgical treatment, additional31.5%
Treatment with medication(s)31.5%
Cardiopulmonary arrest21%

Patient problem codes are present mainly in reports filed since 2019 and are often blank.

In context

MeasureLiberte Monorail Coronary Stent Delivery SystemProduct code MAFAll MAUDE reports
Reports19423,27926,136,888
Share of that pool—0.8%0%
Classified as death, per 1,000 reports36769
Classified as injury29.4%51.3%36.2%
Classified as malfunction67%40.4%62.3%
Filed by the manufacturer99.5%95.6%94.9%

Shares are of reports, not of devices in use. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data."

Other brands with product code MAF

BrandReportsLatest 12 monthsClassified as death
Graftmaster Rx Coronary Stent Graft System2,163013.1%
Multi-Link Rx Vision Coronary Stent System1,87504.2%
Jostent Graftmaster1,373023.5%
Express2 Monorail Coronary Stent Delivery System88102.5%
Multi-Link Mini Vision Rx Coronary Stent System86704.7%
Liberte' Monorail Coronary Stent Delivery System80203.4%
Multi-Link 862111.6%
Rebel62001.8%
Veriflex Liberte Coronary Stent Delivery System603018.6%
Integrity Rx53308.4%
Graftmaster5681319.9%
Libert41500.7%
Omega35301.4%
Multi-Link Rx Zeta Coronary Stent System35106.6%
Acs Rx Multi-Link Coronary Stent System32766.1%

Ordered by report count for navigation only. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data." FDA also states that "common products may have a higher number of adverse events due to the higher total number of people using the product."

Questions about Liberte Monorail Coronary Stent Delivery System reports

How many FDA reports name Liberte Monorail Coronary Stent Delivery System?

194 medical device reports in the openFDA MAUDE release of 28 Sep 2026, covering reports received through August 2026; 0 in the latest 12 months.

What kinds of events are reported?

malfunction (67%), injury (29.4%) and death (3.6%). "Event type" is how the report was classified when filed: death, injury, malfunction or other.

What device problems are coded?

device damaged prior to use (32.5%), dislodged (25.8%), device remains implanted (21.6%), failure to advance (19.1%) and replace (13.4%). These are FDA's device problem codes as entered on the report.

Who files these reports?

manufacturer reports (99.5%). Manufacturers and user facilities are required to report; voluntary reports come from health professionals and the public.

Do these reports show that Liberte Monorail Coronary Stent Delivery System was at fault?

No. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data." FDA adds that "a causal relationship cannot be established between product and reactions listed in a report."

How do I report a problem with a medical device?

Through FDA MedWatch (Form FDA 3500 for health professionals and consumers), or to the manufacturer. See the guide on how to report.

Where this comes from. Counts are built from the openFDA Device Adverse Event (MAUDE) bulk export released 28 Sep 2026, which holds reports FDA received through 31 Aug 2026. Brand, generic and manufacturer names are as written on the reports; product code names come from FDA's device classification. A report counts here when any device it lists carries this brand name after punctuation and capitalisation are normalised. No report narrative, lot number, patient detail or reporter identity is published. See the methodology and sources; FDA's record is authoritative, and corrections are handled within five working days.

Drug data (FAERS) through 30 Jun 2026; device data (MAUDE) through 31 Aug 2026. Not medical advice.