Heartsine Samaritan 500p And Pad Pak: medical device reports filed with FDA

180 reports name it, 2014–2017. Manufacturer given most often on reports: Heartsine Technologies. Product code MKJ.

180
device reports naming the brand
0% of all MAUDE reports · about 15 a year
0
reports, 12 months to August 2026
0 in the 12 months before
99.4%
classified as malfunction
96.8% across the product code
0.6%
classified as death, as reported
1 reports · not verified by FDA

180 medical device reports received by FDA name the brand "Heartsine Samaritan 500p And Pad Pak" (automated external defibrillator); the manufacturer given most often on reports is Heartsine Technologies; received from February 2014 to November 2017. Brand names are as the reporter or manufacturer wrote them, so one product can appear under several spellings.

0 reports arrived in the 12 months to August 2026, and none in the 12 months before. FDA releases MAUDE data monthly; reports can arrive months after an event, so the newest months grow in later releases. The event types recorded are malfunction (99.4%) and death (0.6%); across all automated external defibrillators (non-wearable) reports (product code MKJ) death is recorded in 1.7% and malfunction in 96.8%. Event type is the reporter's classification of the report, not a verified outcome.

The device problems coded most often are device operates differently than expected (70.6%), device displays incorrect message (26.7%) and failure to power up (7.2%). The patient problems coded most often are no patient involvement, death and shock. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data."

Reports by month, five years

No report naming Heartsine Samaritan 500p And Pad Pak was received in the five years to August 2026; the latest was received in November 2017.

By year received

030592014: 3120142015: 4020152016: 5920162017: 502017

Event type and report source

Event type, as classified on the report

Death0.6%1
Injury0%0
Malfunction99.4%179
Other0%0
Not given0%0

Who filed the report

Manufacturer report100%180
Voluntary report0%0
User facility report0%0
Distributor report0%0
Not given0%0

Grey bar: all 269,686 reports carrying product code MKJ. Event type is the filer's classification and is not verified by FDA.

Device problems coded

Device problem (FDA code)ReportsShareShare across product code
Device operates differently than expectedthe device behaved unexpectedly12770.6%11.8%
Device displays incorrect message4826.7%11.6%
Failure to power up137.2%13%
Self-activation or keying116.1%3%
Device maintenance issue105.6%0.1%
Application program version or upgrade problem63.3%0.1%
Data problem42.2%0%
Failure to shut off31.7%0.1%
Noise, audible31.7%0.4%
Premature discharge of battery31.7%1%
Battery problema problem with the battery21.1%2.5%
Device inoperablethe device could not be used21.1%1.9%
Improper device output21.1%0.1%
Insufficient device problem information21.1%0.5%
Low battery21.1%0.2%
No display/image21.1%4.2%
Operating system version or upgrade problem21.1%0.1%
Computer software problema software problem10.6%0.1%
Connection problema connection problem10.6%0.5%
Defibrillation/stimulation problem10.6%3.2%

FDA's device problem codes as entered on the report; one report can carry several. Generic codes such as "no apparent adverse event" are left out.

Patient problems coded

Patient problem (FDA code)ReportsShare
No patient involvement16692.2%
Deaththe patient died; cause not stated by this term10.6%
Shockshock, a collapse of the circulation10.6%

Patient problem codes are present mainly in reports filed since 2019 and are often blank.

In context

MeasureHeartsine Samaritan 500p And Pad PakProduct code MKJAll MAUDE reports
Reports180269,68626,136,888
Share of that pool—0.1%0%
Classified as death, per 1,000 reports6179
Classified as injury0%0.7%36.2%
Classified as malfunction99.4%96.8%62.3%
Filed by the manufacturer100%99.3%94.9%

Shares are of reports, not of devices in use. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data."

Other brands with product code MKJ

BrandReportsLatest 12 monthsClassified as death
M Series27,11242.3%
Heartstart Mrx18,59200.7%
HeartStart MRx -EMS Defibrillator16,166330.8%
Heart Start XL15,944950.9%
R Series Defibrillator15,39300.9%
X Series13,9831,6922.7%
HeartStart XL+ Defibrillator/Monitor13,1882100.4%
Heartstart Onsite10,96400.8%
Aed Plus9,2254232.2%
Heartsine Samaritan 300p And Pad Pak8,19700.3%
E Series Defibrillator8,05201.5%
Lifepak R 15 Monitor/Defibrillator6,1174631.4%
Heartstart Frx5,97821.3%
Efficia Dfm1005,07600.6%
LIFEPAK 15 defibrillator/monitor4,7163691%

Ordered by report count for navigation only. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data." FDA also states that "common products may have a higher number of adverse events due to the higher total number of people using the product."

Questions about Heartsine Samaritan 500p And Pad Pak reports

How many FDA reports name Heartsine Samaritan 500p And Pad Pak?

180 medical device reports in the openFDA MAUDE release of 28 Sep 2026, covering reports received through August 2026; 0 in the latest 12 months.

What kinds of events are reported?

malfunction (99.4%) and death (0.6%). "Event type" is how the report was classified when filed: death, injury, malfunction or other.

What device problems are coded?

device operates differently than expected (70.6%), device displays incorrect message (26.7%), failure to power up (7.2%), self-activation or keying (6.1%) and device maintenance issue (5.6%). These are FDA's device problem codes as entered on the report.

Who files these reports?

manufacturer reports (100%). Manufacturers and user facilities are required to report; voluntary reports come from health professionals and the public.

Do these reports show that Heartsine Samaritan 500p And Pad Pak was at fault?

No. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data." FDA adds that "a causal relationship cannot be established between product and reactions listed in a report."

How do I report a problem with a medical device?

Through FDA MedWatch (Form FDA 3500 for health professionals and consumers), or to the manufacturer. See the guide on how to report.

Where this comes from. Counts are built from the openFDA Device Adverse Event (MAUDE) bulk export released 28 Sep 2026, which holds reports FDA received through 31 Aug 2026. Brand, generic and manufacturer names are as written on the reports; product code names come from FDA's device classification. A report counts here when any device it lists carries this brand name after punctuation and capitalisation are normalised. No report narrative, lot number, patient detail or reporter identity is published. See the methodology and sources; FDA's record is authoritative, and corrections are handled within five working days.

Drug data (FAERS) through 30 Jun 2026; device data (MAUDE) through 31 Aug 2026. Not medical advice.