Reported Reactions

Devices › Stapler, surgical

Device brand name · Linear cutters - endoscopic

Endopath Thoracic Endoscopic Linear Cutter With Safety: medical device reports filed with FDA

366 reports name it, 1998–2001. Manufacturer given most often on reports: Ethicon Endo-Surgery. Product code GAG.

366
device reports naming the brand
0% of all MAUDE reports · about 13 a year
0
reports, 12 months to August 2026
0 in the 12 months before
90.4%
classified as malfunction
72.9% across the product code
0%
classified as death, as reported
0 reports · not verified by FDA

366 medical device reports received by FDA name the brand "Endopath Thoracic Endoscopic Linear Cutter With Safety" (linear cutters - endoscopic); the manufacturer given most often on reports is Ethicon Endo-Surgery; received from April 1998 to November 2001. Brand names are as the reporter or manufacturer wrote them, so one product can appear under several spellings.

0 reports arrived in the 12 months to August 2026, and none in the 12 months before. FDA releases MAUDE data monthly; reports can arrive months after an event, so the newest months grow in later releases. The event types recorded are malfunction (90.4%) and injury (9.6%); across all stapler, surgical reports (product code GAG) death is recorded in 1% and malfunction in 72.9%. Event type is the reporter's classification of the report, not a verified outcome.

The device problems coded most often are replace (65.3%), sticking (26.8%) and misfire (24.6%). The patient problems coded most often are failure to anastomose, surgery, prolonged and bleeding. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data."

Reports by month, five years

No report naming Endopath Thoracic Endoscopic Linear Cutter With Safety was received in the five years to August 2026; the latest was received in November 2001.

By year received

0641281998: 12819981999: 12619992000: 7320002001: 392001

Event type and report source

Event type, as classified on the report

Death0%0
Injury9.6%35
Malfunction90.4%331
Other0%0
Not given0%0

Who filed the report

Manufacturer report99.7%365
Voluntary report0%0
User facility report0%0
Distributor report0%0
Not given0.3%1

Grey bar: all 26,848 reports carrying product code GAG. Event type is the filer's classification and is not verified by FDA.

Device problems coded

Device problem (FDA code)ReportsShareShare across product code
Replace23965.3%35.2%
Sticking9826.8%10.9%
Misfire9024.6%8.9%
Failure to form staple6116.7%27.4%
Failure to fire5515%8.9%
Failure to adhere or bond349.3%1.2%
Failure to cut215.7%3.6%
Detachment of device component205.5%1.8%
Breakthe device broke164.4%1.9%
Component(s), broken123.3%1.1%
Material separation102.7%0.5%
Noise92.5%0.6%
Close, difficult to82.2%0.7%
Difficult to removethe device was hard to remove71.9%5.7%
Loose61.6%0.5%
Other (for use when an appropriate device code cannot be identified)61.6%1.2%
Dislodged41.1%0.1%
Filling problem41.1%0.3%
Device issuea problem with the device30.8%15.9%
Failure to deliverthe device did not deliver the dose or item30.8%0.8%

FDA's device problem codes as entered on the report; one report can carry several. Generic codes such as "no apparent adverse event" are left out.

Patient problems coded

Patient problem (FDA code)ReportsShare
Failure to anastomose9425.7%
Surgery, prolonged339%
Bleeding133.6%
Foreign body, removal of133.6%
Surgical procedure, additional133.6%
Blood loss92.5%
Other (for use when an appropriate patient code cannot be identified)61.6%
Tissue damage51.4%
Surgical procedure41.1%
Laparotomy30.8%
Dural tear20.5%
Perforation of vessels20.5%
Surgical procedure, repeated20.5%
Transfusion of blood products20.5%
Exposure to body fluids10.3%

Patient problem codes are present mainly in reports filed since 2019 and are often blank.

In context

MeasureEndopath Thoracic Endoscopic Linear Cutter With SafetyProduct code GAGAll MAUDE reports
Reports36626,84826,136,888
Share of that pool—1.4%0%
Classified as death, per 1,000 reports0109
Classified as injury9.6%25.1%36.2%
Classified as malfunction90.4%72.9%62.3%
Filed by the manufacturer99.7%91.8%94.9%

Shares are of reports, not of devices in use. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data."

Other brands with product code GAG

BrandReportsLatest 12 monthsClassified as death
Endopath Endoscopic Multifeed Stapler1,70600%
Proximate Linear Cutter1,77611.3%
Eea4,9225420.8%
Gia4,8994040.9%
Proximate I L S Intraluminal Stapler70902%
Proximate Reloadable Linear Stapler1,02501.4%
Endo Gia Universal 12mm Single Use Inst1,07701.8%
Auto Suture Roticulator 55-4 845100.2%
Proximate Access 55 Articulating Linear Stapler39800.5%
Ta1,5411421%
Auto Suture Premium Plus Ceea 31mm35700.3%
Auto Suture Roticulator 55 Poly - 20035300%
Auto Suture Roticulator 55-3 531400.6%
Endopath Endoscopic Linear Cutter32200%
Echelon1,3525843.2%

Ordered by report count for navigation only. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data." FDA also states that "common products may have a higher number of adverse events due to the higher total number of people using the product."

Questions about Endopath Thoracic Endoscopic Linear Cutter With Safety reports

How many FDA reports name Endopath Thoracic Endoscopic Linear Cutter With Safety?

366 medical device reports in the openFDA MAUDE release of 28 Sep 2026, covering reports received through August 2026; 0 in the latest 12 months.

What kinds of events are reported?

malfunction (90.4%) and injury (9.6%). "Event type" is how the report was classified when filed: death, injury, malfunction or other.

What device problems are coded?

replace (65.3%), sticking (26.8%), misfire (24.6%), failure to form staple (16.7%) and failure to fire (15%). These are FDA's device problem codes as entered on the report.

Who files these reports?

manufacturer reports (99.7%). Manufacturers and user facilities are required to report; voluntary reports come from health professionals and the public.

Do these reports show that Endopath Thoracic Endoscopic Linear Cutter With Safety was at fault?

No. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data." FDA adds that "a causal relationship cannot be established between product and reactions listed in a report."

How do I report a problem with a medical device?

Through FDA MedWatch (Form FDA 3500 for health professionals and consumers), or to the manufacturer. See the guide on how to report.

Where this comes from. Counts are built from the openFDA Device Adverse Event (MAUDE) bulk export released 28 Sep 2026, which holds reports FDA received through 31 Aug 2026. Brand, generic and manufacturer names are as written on the reports; product code names come from FDA's device classification. A report counts here when any device it lists carries this brand name after punctuation and capitalisation are normalised. No report narrative, lot number, patient detail or reporter identity is published. See the methodology and sources; FDA's record is authoritative, and corrections are handled within five working days.

Drug data (FAERS) through 30 Jun 2026; device data (MAUDE) through 31 Aug 2026. Not medical advice.