Baha Flange And Abutment: medical device reports filed with FDA

188 reports name it, 2015–2016. Manufacturer given most often on reports: Cochlear Bone Anchored Solutions. Product code LXB.

188
device reports naming the brand
0% of all MAUDE reports · about 16 a year
0
reports, 12 months to August 2026
0 in the 12 months before
1.1%
classified as malfunction
0.6% across the product code
0%
classified as death, as reported
0 reports · not verified by FDA

188 medical device reports received by FDA name the brand "Baha Flange And Abutment" (lxb product code); the manufacturer given most often on reports is Cochlear Bone Anchored Solutions; received from January 2015 to April 2016. Brand names are as the reporter or manufacturer wrote them, so one product can appear under several spellings.

0 reports arrived in the 12 months to August 2026, and none in the 12 months before. FDA releases MAUDE data monthly; reports can arrive months after an event, so the newest months grow in later releases. The event types recorded are injury (98.4%) and malfunction (1.1%); across all hearing aid, bone conduction reports (product code LXB) death is recorded in 0% and malfunction in 0.6%. Event type is the reporter's classification of the report, not a verified outcome.

The device problems coded most often are loss of osseointegration (16.5%), insufficient device problem information (5.3%) and contamination (0.5%). The patient problems coded most often are hearing impairment, bacterial infection and irritation. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data."

Reports by month, five years

No report naming Baha Flange And Abutment was received in the five years to August 2026; the latest was received in April 2016.

Event type and report source

Event type, as classified on the report

Death0%0
Injury98.4%185
Malfunction1.1%2
Other0%0
Not given0.5%1

Who filed the report

Manufacturer report100%188
Voluntary report0%0
User facility report0%0
Distributor report0%0
Not given0%0

Grey bar: all 7,135 reports carrying product code LXB. Event type is the filer's classification and is not verified by FDA.

Device problems coded

Device problem (FDA code)ReportsShareShare across product code
Loss of osseointegration3116.5%17%
Insufficient device problem information105.3%3.7%
Contamination10.5%0.1%
Loose or intermittent connection10.5%0%

FDA's device problem codes as entered on the report; one report can carry several. Generic codes such as "no apparent adverse event" are left out.

Patient problems coded

Patient problem (FDA code)ReportsShare
Hearing impairment2010.6%
Bacterial infectiona bacterial infection126.4%
Irritationirritation84.3%
Painpain, site not specified73.7%
Impaired healingslow healing52.7%
Head injurya head injury31.6%
Inflammationinflammation31.6%
Cellulitisa skin infection21.1%
Discomfortdiscomfort21.1%
Swellingswelling21.1%
Abscessa collection of pus10.5%
Device overstimulation of tissue10.5%
Skin inflammation10.5%
Skin irritationirritated skin10.5%

Patient problem codes are present mainly in reports filed since 2019 and are often blank.

In context

MeasureBaha Flange And AbutmentProduct code LXBAll MAUDE reports
Reports1887,13526,136,888
Share of that pool—2.6%0%
Classified as death, per 1,000 reports009
Classified as injury98.4%98.3%36.2%
Classified as malfunction1.1%0.6%62.3%
Filed by the manufacturer100%83.7%94.9%

Shares are of reports, not of devices in use. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data."

Other brands with product code LXB

BrandReportsLatest 12 monthsClassified as death
Flange Fixture And Abutment2,92000%
BIM400 Implant Magnet1,1551530%
Asku4,7522101.1%
BI300 Implant 4 mm314280%
Flange Fixture St 4mm W Baha Abutment19790%
Bi300 Implant 3mm181190%
BIA400 Implant 4mm w Abutment 12mm673350%
BIA400 Implant 4mm w Abutment 10mm833680%
BIA400 Implant 4mm w Abutment 8mm502330%
Ba400 Abutment 8mm31270%
BA400 Abutment 12mm321210%
BA400 Abutment 10mm419180%
BIA400 Implant 4mm w Abutment 14mm205250%
Nucleus 24 Channel Cochlear Implant System12,13700.1%
Cochlear Osia OSI200 Implant1,8242470.1%

Ordered by report count for navigation only. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data." FDA also states that "common products may have a higher number of adverse events due to the higher total number of people using the product."

Questions about Baha Flange And Abutment reports

How many FDA reports name Baha Flange And Abutment?

188 medical device reports in the openFDA MAUDE release of 28 Sep 2026, covering reports received through August 2026; 0 in the latest 12 months.

What kinds of events are reported?

injury (98.4%) and malfunction (1.1%). "Event type" is how the report was classified when filed: death, injury, malfunction or other.

What device problems are coded?

loss of osseointegration (16.5%), insufficient device problem information (5.3%), contamination (0.5%) and loose or intermittent connection (0.5%). These are FDA's device problem codes as entered on the report.

Who files these reports?

manufacturer reports (100%). Manufacturers and user facilities are required to report; voluntary reports come from health professionals and the public.

Do these reports show that Baha Flange And Abutment was at fault?

No. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data." FDA adds that "a causal relationship cannot be established between product and reactions listed in a report."

How do I report a problem with a medical device?

Through FDA MedWatch (Form FDA 3500 for health professionals and consumers), or to the manufacturer. See the guide on how to report.

Where this comes from. Counts are built from the openFDA Device Adverse Event (MAUDE) bulk export released 28 Sep 2026, which holds reports FDA received through 31 Aug 2026. Brand, generic and manufacturer names are as written on the reports; product code names come from FDA's device classification. A report counts here when any device it lists carries this brand name after punctuation and capitalisation are normalised. No report narrative, lot number, patient detail or reporter identity is published. See the methodology and sources; FDA's record is authoritative, and corrections are handled within five working days.

Drug data (FAERS) through 30 Jun 2026; device data (MAUDE) through 31 Aug 2026. Not medical advice.