Reported Reactions

Devices › Coronary drug-eluting stent

Device brand name · Drug eluting coronary stent delivery system

XIENCE Xpedition: medical device reports filed with FDA

663 reports name it, 2013–2026. Manufacturer given most often on reports: Abbott Vascular. Product code NIQ.

663
device reports naming the brand
0% of all MAUDE reports · about 49 a year
129
reports, 12 months to August 2026
159 in the 12 months before
19.5%
classified as malfunction
42.8% across the product code
3.8%
classified as death, as reported
25 reports · not verified by FDA

663 medical device reports received by FDA name the brand "XIENCE Xpedition" (drug eluting coronary stent delivery system); the manufacturer given most often on reports is Abbott Vascular; received from February 2013 to August 2026. Brand names are as the reporter or manufacturer wrote them, so one product can appear under several spellings.

129 reports arrived in the 12 months to August 2026, down 19% from 159 in the 12 months before. FDA releases MAUDE data monthly; reports can arrive months after an event, so the newest months grow in later releases. The event types recorded are injury (76.3%), malfunction (19.5%) and death (3.8%); across all coronary drug-eluting stent reports (product code NIQ) death is recorded in 8.7% and malfunction in 42.8%. Event type is the reporter's classification of the report, not a verified outcome.

The device problems coded most often are failure to advance (9.7%), material separation (9.2%) and difficult to remove (5.7%). The patient problems coded most often are intimal dissection, vascular dissection and myocardial infarction. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data."

Reports by month, five years

01428Sep 2021: 0Oct 2021: 0Nov 2021: 0Dec 2021: 02022Jan 2022: 0Feb 2022: 0Mar 2022: 0Apr 2022: 0May 2022: 0Jun 2022: 0Jul 2022: 0Aug 2022: 0Sep 2022: 0Oct 2022: 0Nov 2022: 0Dec 2022: 02023Jan 2023: 0Feb 2023: 0Mar 2023: 0Apr 2023: 0May 2023: 0Jun 2023: 0Jul 2023: 0Aug 2023: 0Sep 2023: 0Oct 2023: 0Nov 2023: 0Dec 2023: 02024Jan 2024: 1Feb 2024: 0Mar 2024: 0Apr 2024: 3May 2024: 1Jun 2024: 3Jul 2024: 8Aug 2024: 12Sep 2024: 7Oct 2024: 17Nov 2024: 10Dec 2024: 282025Jan 2025: 14Feb 2025: 27Mar 2025: 5Apr 2025: 8May 2025: 3Jun 2025: 9Jul 2025: 7Aug 2025: 24Sep 2025: 12Oct 2025: 11Nov 2025: 9Dec 2025: 162026Jan 2026: 17Feb 2026: 11Mar 2026: 12Apr 2026: 11May 2026: 9Jun 2026: 5Jul 2026: 8Aug 2026: 8

Reports by the month FDA received them. FDA releases MAUDE data monthly; reports can arrive months after an event, so the newest months grow in later releases.

By year received

0941872013: 1420132019: 18720192020: 14620202024: 9020242025: 14520252026: 812026

Event type and report source

Event type, as classified on the report

Death3.8%25
Injury76.3%506
Malfunction19.5%129
Other0%0
Not given0.5%3

Who filed the report

Manufacturer report97.9%649
Voluntary report0.8%5
User facility report0%0
Distributor report0%0
Not given1.4%9

Grey bar: all 128,932 reports carrying product code NIQ. Event type is the filer's classification and is not verified by FDA.

Device problems coded

Device problem (FDA code)ReportsShareShare across product code
Failure to advance649.7%15.8%
Material separation619.2%0.7%
Difficult to removethe device was hard to remove385.7%6%
Device dislodged or dislocated274.1%8.5%
Improper or incorrect procedure or method274.1%2.6%
Material deformation203%10.7%
Difficult to advance192.9%1.3%
Breakthe device broke172.6%3.1%
Deformation due to compressive stress121.8%0.2%
Stretched111.7%0.2%
Material rupture81.2%1%
Deflation problem71.1%0.9%
Activation failure60.9%0.4%
Device damaged by another device60.9%1.4%
Leak/splashthe device leaked50.8%0.8%
Patient-device incompatibilitythe device did not suit the patient50.8%0.2%
Inflation problem40.6%1.3%
Material split, cut or torn30.5%0.1%
Burst container or vessel20.3%0.4%
Detachment of device component20.3%1.9%

FDA's device problem codes as entered on the report; one report can carry several. Generic codes such as "no apparent adverse event" are left out.

Patient problems coded

Patient problem (FDA code)ReportsShare
Intimal dissection21933%
Vascular dissection21232%
Myocardial infarctionheart attack263.9%
Angina203%
Stenosis162.4%
Thrombosis/thrombus142.1%
No patient involvement111.7%
Thrombosis71.1%
Cardiac arrestthe heart stopped60.9%
Foreign body in patientpart of a device left in the patient50.8%
Occlusion50.8%
Ischemia40.6%
Perforation of vessels40.6%
Deaththe patient died; cause not stated by this term30.5%
Device embedded in tissue or plaque30.5%

Patient problem codes are present mainly in reports filed since 2019 and are often blank.

In context

MeasureXIENCE XpeditionProduct code NIQAll MAUDE reports
Reports663128,93226,136,888
Share of that pool—0.5%0%
Classified as death, per 1,000 reports38879
Classified as injury76.3%48.3%36.2%
Classified as malfunction19.5%42.8%62.3%
Filed by the manufacturer97.9%98.7%94.9%

Shares are of reports, not of devices in use. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data."

Other brands with product code NIQ

BrandReportsLatest 12 monthsClassified as death
Cypher Sirolimus-Eluting Coronary Stent15,051010.3%
Taxus Express2 Paclitaxel-Eluting Coronary Stent System10,256012.5%
Synergy14,271843.5%
Xience V Everolimus Eluting Coronary Stent System6,990911.6%
Promus PREMIER6,1591116.3%
Resolute Onyx Rx5,819888.7%
Promus Element Plus5,238010.2%
Promus Element4,77005.5%
Resolute Integrity Rx4,720707.9%
Taxus Liberte Paclitaxel-Eluting Coronary Stent System4,54305.2%
Xience Xpedition Everolimus Eluting Coronary Stent System4,19904%
Synergy Xd2,8133794%
Promus Everolimus Eluting Coronary Stent System2,734011.3%
Xience Alpine Everolimus Eluting Coronary Stent System2,68103.2%
Endeavor Sprint Rx2,449028.5%

Ordered by report count for navigation only. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data." FDA also states that "common products may have a higher number of adverse events due to the higher total number of people using the product."

Questions about XIENCE Xpedition reports

How many FDA reports name XIENCE Xpedition?

663 medical device reports in the openFDA MAUDE release of 28 Sep 2026, covering reports received through August 2026; 129 in the latest 12 months.

What kinds of events are reported?

injury (76.3%), malfunction (19.5%) and death (3.8%). "Event type" is how the report was classified when filed: death, injury, malfunction or other.

What device problems are coded?

failure to advance (9.7%), material separation (9.2%), difficult to remove (5.7%), device dislodged or dislocated (4.1%) and improper or incorrect procedure or method (4.1%). These are FDA's device problem codes as entered on the report.

Who files these reports?

manufacturer reports (97.9%) and voluntary reports (0.8%). Manufacturers and user facilities are required to report; voluntary reports come from health professionals and the public.

Do these reports show that XIENCE Xpedition was at fault?

No. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data." FDA adds that "a causal relationship cannot be established between product and reactions listed in a report."

How do I report a problem with a medical device?

Through FDA MedWatch (Form FDA 3500 for health professionals and consumers), or to the manufacturer. See the guide on how to report.

Where this comes from. Counts are built from the openFDA Device Adverse Event (MAUDE) bulk export released 28 Sep 2026, which holds reports FDA received through 31 Aug 2026. Brand, generic and manufacturer names are as written on the reports; product code names come from FDA's device classification. A report counts here when any device it lists carries this brand name after punctuation and capitalisation are normalised. No report narrative, lot number, patient detail or reporter identity is published. See the methodology and sources; FDA's record is authoritative, and corrections are handled within five working days.

Drug data (FAERS) through 30 Jun 2026; device data (MAUDE) through 31 Aug 2026. Not medical advice.