Reported Reactions

Devices › Implantable cardioverter defibrillator (non-crt)

Device brand name · Defibrillator automatic implantable cardioverter

Virtuoso: medical device reports filed with FDA

600 reports name it, 2009–2019. Manufacturer given most often on reports: Medtronic Med Rel Medtronic Puerto Rico. Product code LWS.

600
device reports naming the brand
0% of all MAUDE reports · about 34 a year
0
reports, 12 months to August 2026
0 in the 12 months before
14%
classified as malfunction
37.4% across the product code
2.7%
classified as death, as reported
16 reports · not verified by FDA

600 medical device reports received by FDA name the brand "Virtuoso" (defibrillator automatic implantable cardioverter); the manufacturer given most often on reports is Medtronic Med Rel Medtronic Puerto Rico; received from January 2009 to April 2019. Brand names are as the reporter or manufacturer wrote them, so one product can appear under several spellings.

0 reports arrived in the 12 months to August 2026, and none in the 12 months before. FDA releases MAUDE data monthly; reports can arrive months after an event, so the newest months grow in later releases. The event types recorded are injury (83%), malfunction (14%) and death (2.7%); across all implantable cardioverter defibrillator (non-crt) reports (product code LWS) death is recorded in 2.7% and malfunction in 37.4%. Event type is the reporter's classification of the report, not a verified outcome.

The device problems coded most often are electrical /electronic property problem (26.8%), premature discharge of battery (17.3%) and invalid sensing (12.3%). The patient problems coded most often are shock from patient lead(s), death and shock. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data."

Reports by month, five years

No report naming Virtuoso was received in the five years to August 2026; the latest was received in April 2019.

By year received

01613212009: 620092011: 320112013: 1020132014: 32120142015: 10420152016: 7320162017: 3720172018: 3720182019: 92019

Event type and report source

Event type, as classified on the report

Death2.7%16
Injury83%498
Malfunction14%84
Other0%0
Not given0.3%2

Who filed the report

Manufacturer report99.2%595
Voluntary report0%0
User facility report0%0
Distributor report0%0
Not given0.8%5

Grey bar: all 380,959 reports carrying product code LWS. Event type is the filer's classification and is not verified by FDA.

Device problems coded

Device problem (FDA code)ReportsShareShare across product code
Electrical /electronic property probleman electrical or electronic problem16126.8%0.8%
Premature discharge of battery10417.3%8.1%
Invalid sensing7412.3%0.6%
Inappropriate/inadequate shock/stimulation7312.2%12.8%
Battery problema problem with the battery518.5%2%
Failure to interrogate366%0.9%
Failure to charge264.3%0.3%
Protective measures problem213.5%0.2%
Pacing problem203.3%3.8%
Delayed charge time172.8%0.7%
Over-sensing172.8%21.1%
Mechanical problema mechanical problem91.5%1%
Defibrillation/stimulation problem81.3%1%
Inappropriate or unexpected reset61%1.1%
Reset problem61%0.3%
Communication or transmission problemthe device could not communicate or transmit40.7%0.4%
Device operates differently than expectedthe device behaved unexpectedly40.7%1.6%
Unable to obtain readings40.7%0.1%
Under-sensing40.7%3.1%
Charging problem30.5%0%

FDA's device problem codes as entered on the report; one report can carry several. Generic codes such as "no apparent adverse event" are left out.

Patient problems coded

Patient problem (FDA code)ReportsShare
Shock from patient lead(s)7011.7%
Deaththe patient died; cause not stated by this term152.5%
Shockshock, a collapse of the circulation142.3%
Complaint, ill-defined61%
Chest painchest pain50.8%
Electric shockan electric shock40.7%
Painpain, site not specified40.7%
Ventricular tachycardiaa fast rhythm from the lower heart chambers40.7%
Anxietyanxiety30.5%
Cardiac arrestthe heart stopped30.5%
Dyspneashortness of breath30.5%
Hematomaa collection of blood under the skin or in tissue30.5%
Sepsisa severe body-wide response to infection30.5%
Syncopefainting30.5%
Ventricular fibrillationa chaotic rhythm from the lower heart chambers30.5%

Patient problem codes are present mainly in reports filed since 2019 and are often blank.

In context

MeasureVirtuosoProduct code LWSAll MAUDE reports
Reports600380,95926,136,888
Share of that pool—0.2%0%
Classified as death, per 1,000 reports27279
Classified as injury83%59.6%36.2%
Classified as malfunction14%37.4%62.3%
Filed by the manufacturer99.2%97.8%94.9%

Shares are of reports, not of devices in use. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data."

Other brands with product code LWS

BrandReportsLatest 12 monthsClassified as death
Sprint Quattro Secure S MRI SureScan36,8956,4361.4%
Emblem Mri S-Icd21,4803,0880.2%
Sprint Quattro Secure24,23725.2%
Emblem S-Icd17,2502,2370.1%
Sprint Fidelis17,00534014.1%
Sprint Quattro Secure S14,39802.4%
Endotak Reliance25,8972381.2%
Sprint Quattro Secure MRI SureScan15,6061,9031.4%
Endotak Reliance G10,1151,0490.6%
Teligen16,537470.6%
Durata Sts Optim Active Fixation9,6813015.6%
Sprint Quattro5,59102.6%
Reliance 4-Front9,8522,0240.4%
Sprint6,1311612.4%
Vitality 24,77901%

Ordered by report count for navigation only. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data." FDA also states that "common products may have a higher number of adverse events due to the higher total number of people using the product."

Questions about Virtuoso reports

How many FDA reports name Virtuoso?

600 medical device reports in the openFDA MAUDE release of 28 Sep 2026, covering reports received through August 2026; 0 in the latest 12 months.

What kinds of events are reported?

injury (83%), malfunction (14%) and death (2.7%). "Event type" is how the report was classified when filed: death, injury, malfunction or other.

What device problems are coded?

electrical /electronic property problem (26.8%), premature discharge of battery (17.3%), invalid sensing (12.3%), inappropriate/inadequate shock/stimulation (12.2%) and battery problem (8.5%). These are FDA's device problem codes as entered on the report.

Who files these reports?

manufacturer reports (99.2%). Manufacturers and user facilities are required to report; voluntary reports come from health professionals and the public.

Do these reports show that Virtuoso was at fault?

No. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data." FDA adds that "a causal relationship cannot be established between product and reactions listed in a report."

How do I report a problem with a medical device?

Through FDA MedWatch (Form FDA 3500 for health professionals and consumers), or to the manufacturer. See the guide on how to report.

Where this comes from. Counts are built from the openFDA Device Adverse Event (MAUDE) bulk export released 28 Sep 2026, which holds reports FDA received through 31 Aug 2026. Brand, generic and manufacturer names are as written on the reports; product code names come from FDA's device classification. A report counts here when any device it lists carries this brand name after punctuation and capitalisation are normalised. No report narrative, lot number, patient detail or reporter identity is published. See the methodology and sources; FDA's record is authoritative, and corrections are handled within five working days.

Drug data (FAERS) through 30 Jun 2026; device data (MAUDE) through 31 Aug 2026. Not medical advice.