Devices › Stimulator, spinal-cord, totally implanted for pain relief

Device brand name · Stimulator electrical implanted for parkinsonian tremor

Unknown Implantable Neurostimulator: medical device reports filed with FDA

3,843 reports name it, 2008–2020. Manufacturer given most often on reports: Medtronic Neuromodulation. Product code LGW.

3,843
device reports naming the brand
0% of all MAUDE reports · about 216 a year
0
reports, 12 months to August 2026
0 in the 12 months before
29.3%
classified as malfunction
27.3% across the product code
2.2%
classified as death, as reported
84 reports · not verified by FDA

FDA's MAUDE database holds 3,843 reports that name the brand "Unknown Implantable Neurostimulator" (stimulator electrical implanted for parkinsonian tremor), received between September 2008 and December 2020; the manufacturer given most often on reports is Medtronic Neuromodulation. Spellings of one product vary from report to report.

0 reports arrived in the 12 months to August 2026, and none in the 12 months before. FDA releases MAUDE data monthly; reports can arrive months after an event, so the newest months grow in later releases. The event types recorded are injury (68.5%), malfunction (29.3%) and death (2.2%); across all stimulator, spinal-cord, totally implanted for pain relief reports (product code LGW) death is recorded in 0.5% and malfunction in 27.3%. Event type is the reporter's classification of the report, not a verified outcome.

The device problems coded most often are device operates differently than expected (23.8%), high impedance (11.3%) and break (10.5%). The patient problems coded most often are therapeutic effects, unexpected, therapeutic response, decreased and pain. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data."

Reports by month, five years

No report naming Unknown Implantable Neurostimulator was received in the five years to August 2026; the latest was received in December 2020.

By year received

03687362008: 320082011: 42012: 18220122013: 5932014: 73620142015: 7112016: 43920162017: 6002018: 35520182019: 2152020: 52020

Event type and report source

Event type, as classified on the report

Death2.2%84
Injury68.5%2,633
Malfunction29.3%1,126
Other0%0
Not given0%0

Who filed the report

Manufacturer report100%3,843
Voluntary report0%0
User facility report0%0
Distributor report0%0
Not given0%0

Grey bar: all 378,355 reports carrying product code LGW. Event type is the filer's classification and is not verified by FDA.

Device problems coded

Device problem (FDA code)ReportsShareShare across product code
Device operates differently than expectedthe device behaved unexpectedly91423.8%7.5%
High impedance43611.3%9.7%
Breakthe device broke40210.5%1.4%
Migration or expulsion of device39310.2%4.7%
Failure to deliver energy1925%4.4%
Malposition of device1513.9%1.3%
Inappropriate/inadequate shock/stimulation1343.5%3.7%
Insufficient device problem information1072.8%6.8%
Battery problema problem with the battery842.2%7.8%
Device displays incorrect message792.1%1.8%
Unintended collision782%1.9%
Low impedance731.9%0.7%
Electromagnetic compatibility problem711.8%0.8%
Impedance problem701.8%1.9%
Charging problem681.8%11.2%
Low battery631.6%1.2%
Communication or transmission problemthe device could not communicate or transmit591.5%5%
Device or device fragments location unknown551.4%0.2%
Therapy delivered to incorrect body area501.3%1.5%
Electromagnetic interference461.2%0.6%

FDA's device problem codes as entered on the report; one report can carry several. Generic codes such as "no apparent adverse event" are left out.

Patient problems coded

Patient problem (FDA code)ReportsShare
Therapeutic effects, unexpected59615.5%
Therapeutic response, decreased42711.1%
Painpain, site not specified3619.4%
Complaint, ill-defined3198.3%
Cognitive changes1854.8%
Neurological deficit/dysfunction1403.6%
Electric shockan electric shock1343.5%
Ambulation or postural difficulties1153%
Discomfortdiscomfort1002.6%
Dysphasia892.3%
Staphylococcus aureus832.2%
Seizures802.1%
Post operative wound infection752%
Intracranial hemorrhage681.8%
Undesired nerve stimulation661.7%

Patient problem codes are present mainly in reports filed since 2019 and are often blank.

In context

MeasureUnknown Implantable NeurostimulatorProduct code LGWAll MAUDE reports
Reports3,843378,35526,136,888
Share of that pool—1%0%
Classified as death, per 1,000 reports2259
Classified as injury68.5%72%36.2%
Classified as malfunction29.3%27.3%62.3%
Filed by the manufacturer100%99.5%94.9%

Shares are of reports, not of devices in use. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data."

Other brands with product code LGW

BrandReportsLatest 12 monthsClassified as death
Intellis42,0324,7430%
Octrode Lead Kit, 60cm Length47,0375,1330.1%
SureScan33,1234900%
Precision?26,0204460.4%
Proclaim 5 Elite Implantable Pulse Generator20,8162,0570.1%
Precision Spectra ?16,8589710.5%
Restore Ultra13,500390.1%
Eon Mini IPG, 16-Channel Rechargeable14,1761110.2%
Restore Sensor10,934400.1%
Spectra WaveWriter?7,7661,0930.4%
Penta 3mm Lead, 60 cm9,6178390.3%
Senza6,42371815.1%
Eon Mini9,12200.6%
Proclaim 7 Elite Implantable Pulse Generator5,8363330.1%
WaveWriter Alpha?4,9651,5910.9%

Ordered by report count for navigation only. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data." FDA also states that "common products may have a higher number of adverse events due to the higher total number of people using the product."

Questions about Unknown Implantable Neurostimulator reports

How many FDA reports name Unknown Implantable Neurostimulator?

3,843 medical device reports in the openFDA MAUDE release of 28 Sep 2026, covering reports received through August 2026; 0 in the latest 12 months.

What kinds of events are reported?

injury (68.5%), malfunction (29.3%) and death (2.2%). "Event type" is how the report was classified when filed: death, injury, malfunction or other.

What device problems are coded?

device operates differently than expected (23.8%), high impedance (11.3%), break (10.5%), migration or expulsion of device (10.2%) and failure to deliver energy (5%). These are FDA's device problem codes as entered on the report.

Who files these reports?

manufacturer reports (100%). Manufacturers and user facilities are required to report; voluntary reports come from health professionals and the public.

Do these reports show that Unknown Implantable Neurostimulator was at fault?

No. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data." FDA adds that "a causal relationship cannot be established between product and reactions listed in a report."

How do I report a problem with a medical device?

Through FDA MedWatch (Form FDA 3500 for health professionals and consumers), or to the manufacturer. See the guide on how to report.

Where this comes from. Counts are built from the openFDA Device Adverse Event (MAUDE) bulk export released 28 Sep 2026, which holds reports FDA received through 31 Aug 2026. Brand, generic and manufacturer names are as written on the reports; product code names come from FDA's device classification. A report counts here when any device it lists carries this brand name after punctuation and capitalisation are normalised. No report narrative, lot number, patient detail or reporter identity is published. See the methodology and sources; FDA's record is authoritative, and corrections are handled within five working days.

Drug data (FAERS) through 30 Jun 2026; device data (MAUDE) through 31 Aug 2026. Not medical advice.