Unicel Dxc 600 Pro Synchron Chemistry Analyzer: medical device reports filed with FDA

578 reports name it, 2009–2013. Manufacturer given most often on reports: Beckman Coulter. Product code JJE.

578
device reports naming the brand
0% of all MAUDE reports · about 33 a year
0
reports, 12 months to August 2026
0 in the 12 months before
87%
classified as malfunction
95.5% across the product code
0%
classified as death, as reported
0 reports · not verified by FDA

FDA's MAUDE database holds 578 reports that name the brand "Unicel Dxc 600 Pro Synchron Chemistry Analyzer" (clinical chemistry analyzer), received between February 2009 and October 2013; the manufacturer given most often on reports is Beckman Coulter. Spellings of one product vary from report to report.

0 reports arrived in the 12 months to August 2026, and none in the 12 months before. FDA releases MAUDE data monthly; reports can arrive months after an event, so the newest months grow in later releases. The event types recorded are malfunction (87%) and injury (2.2%); across all analyzer, chemistry (photometric, discrete), for clinical use reports (product code JJE) death is recorded in 0% and malfunction in 95.5%. Event type is the reporter's classification of the report, not a verified outcome.

The device problems coded most often are low test results (32.4%), leak/splash (17%) and fluid/blood leak (14.2%). The patient problems coded most often are chemical exposure, no patient involvement and test result. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data."

Reports by month, five years

No report naming Unicel Dxc 600 Pro Synchron Chemistry Analyzer was received in the five years to August 2026; the latest was received in October 2013.

By year received

01623242009: 820092010: 19220102011: 32420112012: 1420122013: 402013

Event type and report source

Event type, as classified on the report

Death0%0
Injury2.2%13
Malfunction87%503
Other0%0
Not given10.7%62

Who filed the report

Manufacturer report100%578
Voluntary report0%0
User facility report0%0
Distributor report0%0
Not given0%0

Grey bar: all 79,280 reports carrying product code JJE. Event type is the filer's classification and is not verified by FDA.

Device problems coded

Device problem (FDA code)ReportsShareShare across product code
Low test results18732.4%24.5%
Leak/splashthe device leaked9817%3.1%
Fluid/blood leak8214.2%3.6%
High test results7913.7%27.1%
Incorrect or inadequate test results7613.1%12%
Device displays incorrect message213.6%2.8%
Chemical spillage142.4%0.2%
Crackthe device cracked132.2%0.2%
Device operates differently than expectedthe device behaved unexpectedly71.2%0.8%
Breakthe device broke50.9%0.2%
False positive result50.9%2.6%
Calibration problem40.7%0.3%
Device emits odor40.7%0.3%
Detachment of device component30.5%0.1%
Device slipped30.5%0.1%
Excess flow or over-infusion30.5%0.1%
Improper or incorrect procedure or method20.3%0.3%
Microbial contamination of device20.3%0.1%
Moisture or humidity problem20.3%0%
Overfill20.3%0.1%

FDA's device problem codes as entered on the report; one report can carry several. Generic codes such as "no apparent adverse event" are left out.

Patient problems coded

Patient problem (FDA code)ReportsShare
Chemical exposure40.7%
No patient involvement40.7%
Test result30.5%
Exposure to body fluids20.3%
Caustic/chemical burns10.2%
Contamination, chemical10.2%
Laceration(s)10.2%
Rashskin rash10.2%
Venipuncture10.2%

Patient problem codes are present mainly in reports filed since 2019 and are often blank.

In context

MeasureUnicel Dxc 600 Pro Synchron Chemistry AnalyzerProduct code JJEAll MAUDE reports
Reports57879,28026,136,888
Share of that pool—0.7%0%
Classified as death, per 1,000 reports009
Classified as injury2.2%1.5%36.2%
Classified as malfunction87%95.5%62.3%
Filed by the manufacturer100%99.6%94.9%

Shares are of reports, not of devices in use. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data."

Other brands with product code JJE

BrandReportsLatest 12 monthsClassified as death
Access 2 Immunoassay System4,71900%
Unicel Dxi 800 Access Immunoassay System3,13300%
cobas 6000 c501 module2,7321940.1%
COBAS 6000 C (501) Module2,1691290%
UniCel DxC 600i SYNCHRON Access Clinical System2,975130%
Unicel Dxc 800 Synchron System2,23200%
Architect I2000sr Analyzer1,78500.1%
cobas c 503 analytical unit1,4155410%
Alinity Ci-Series Level Sensor Bulk Solution1,33900%
Alinity c Processing Module1,3113020.1%
Cobas 8000 C 702 Module1,28300%
Cobas E 411 Immunoassay Analyzer1,15800.1%
AU5800 Clinical Chemistry Analyzer1,151690%
Architect Reaction Vessel1,12400%
Dimension Vista 15001,10240%

Ordered by report count for navigation only. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data." FDA also states that "common products may have a higher number of adverse events due to the higher total number of people using the product."

Questions about Unicel Dxc 600 Pro Synchron Chemistry Analyzer reports

How many FDA reports name Unicel Dxc 600 Pro Synchron Chemistry Analyzer?

578 medical device reports in the openFDA MAUDE release of 28 Sep 2026, covering reports received through August 2026; 0 in the latest 12 months.

What kinds of events are reported?

malfunction (87%) and injury (2.2%). "Event type" is how the report was classified when filed: death, injury, malfunction or other.

What device problems are coded?

low test results (32.4%), leak/splash (17%), fluid/blood leak (14.2%), high test results (13.7%) and incorrect or inadequate test results (13.1%). These are FDA's device problem codes as entered on the report.

Who files these reports?

manufacturer reports (100%). Manufacturers and user facilities are required to report; voluntary reports come from health professionals and the public.

Do these reports show that Unicel Dxc 600 Pro Synchron Chemistry Analyzer was at fault?

No. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data." FDA adds that "a causal relationship cannot be established between product and reactions listed in a report."

How do I report a problem with a medical device?

Through FDA MedWatch (Form FDA 3500 for health professionals and consumers), or to the manufacturer. See the guide on how to report.

Where this comes from. Counts are built from the openFDA Device Adverse Event (MAUDE) bulk export released 28 Sep 2026, which holds reports FDA received through 31 Aug 2026. Brand, generic and manufacturer names are as written on the reports; product code names come from FDA's device classification. A report counts here when any device it lists carries this brand name after punctuation and capitalisation are normalised. No report narrative, lot number, patient detail or reporter identity is published. See the methodology and sources; FDA's record is authoritative, and corrections are handled within five working days.

Drug data (FAERS) through 30 Jun 2026; device data (MAUDE) through 31 Aug 2026. Not medical advice.