Reported Reactions

Devices › Cardiac ablation percutaneous catheter

Device brand name · Cardiac ablation percutaneous catheter

Thermocool Smarttouch Bi-Directional Navigation Catheter: medical device reports filed with FDA

1,224 reports name it, 2014–2017. Manufacturer given most often on reports: Biosense Webster Juarez. Product code LPB.

1,224
device reports naming the brand
0% of all MAUDE reports · about 99 a year
0
reports, 12 months to August 2026
0 in the 12 months before
29%
classified as malfunction
37% across the product code
5%
classified as death, as reported
61 reports · not verified by FDA

FDA's MAUDE database holds 1,224 reports that name the brand "Thermocool Smarttouch Bi-Directional Navigation Catheter" (cardiac ablation percutaneous catheter), received between March 2014 and October 2017; the manufacturer given most often on reports is Biosense Webster Juarez. Spellings of one product vary from report to report.

0 reports arrived in the 12 months to August 2026, and none in the 12 months before. FDA releases MAUDE data monthly; reports can arrive months after an event, so the newest months grow in later releases. The event types recorded are injury (65.8%), malfunction (29%) and death (5%); across all cardiac ablation percutaneous catheter reports (product code LPB) death is recorded in 4.4% and malfunction in 37%. Event type is the reporter's classification of the report, not a verified outcome.

The device problems coded most often are insufficient device problem information (22.1%), device operates differently than expected (9.6%) and device displays incorrect message (7.8%). The patient problems coded most often are cardiac tamponade, low blood pressure/ hypotension and pericardial effusion. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data."

Reports by month, five years

No report naming Thermocool Smarttouch Bi-Directional Navigation Catheter was received in the five years to August 2026; the latest was received in October 2017.

By year received

02074132014: 24320142015: 41320152016: 38520162017: 1832017

Event type and report source

Event type, as classified on the report

Death5%61
Injury65.8%805
Malfunction29%355
Other0%0
Not given0.2%3

Who filed the report

Manufacturer report99.8%1,221
Voluntary report0.2%2
User facility report0%0
Distributor report0%0
Not given0.1%1

Grey bar: all 16,527 reports carrying product code LPB. Event type is the filer's classification and is not verified by FDA.

Device problems coded

Device problem (FDA code)ReportsShareShare across product code
Insufficient device problem information27122.1%6.5%
Device operates differently than expectedthe device behaved unexpectedly1189.6%2.6%
Device displays incorrect message957.8%2.3%
Breakthe device broke584.7%1.5%
Temperature problem413.3%1.6%
Device contamination with chemical or other material383.1%1.3%
Charred322.6%1%
Hole in material282.3%0.7%
Crackthe device cracked272.2%0.7%
Positioning problem272.2%1.3%
Scratched material272.2%0.3%
Noise, audible262.1%0.8%
Signal artifact/noise262.1%1.9%
Improper or incorrect procedure or method221.8%0.7%
Bent191.6%0.4%
No display/image191.6%0.7%
Material integrity problema problem with the device material181.5%0.6%
High impedance171.4%0.9%
Human-device interface problem171.4%0.2%
Cut in material151.2%0.1%

FDA's device problem codes as entered on the report; one report can carry several. Generic codes such as "no apparent adverse event" are left out.

Patient problems coded

Patient problem (FDA code)ReportsShare
Cardiac tamponade54544.5%
Low blood pressure/ hypotension31826%
Pericardial effusionfluid around the heart22518.4%
Deaththe patient died; cause not stated by this term615%
Perforation483.9%
Cardiac arrestthe heart stopped413.3%
Fistula403.3%
Hemorrhage/blood loss/bleeding342.8%
Cardiac perforation302.5%
Stroke/cva262.1%
Ventricular tachycardiaa fast rhythm from the lower heart chambers231.9%
Atrial fibrillationan irregular heart rhythm211.7%
Complete heart block181.5%
Chest painchest pain161.3%
Thrombus131.1%

Patient problem codes are present mainly in reports filed since 2019 and are often blank.

In context

MeasureThermocool Smarttouch Bi-Directional Navigation CatheterProduct code LPBAll MAUDE reports
Reports1,22416,52726,136,888
Share of that pool—7.4%0%
Classified as death, per 1,000 reports50449
Classified as injury65.8%58.2%36.2%
Classified as malfunction29%37%62.3%
Filed by the manufacturer99.8%95.8%94.9%

Shares are of reports, not of devices in use. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data."

Other brands with product code LPB

BrandReportsLatest 12 monthsClassified as death
Thermocool Smart Touch Sf Bi-Directional Navigation Catheter4,538224.5%
ThermoCool SmartTouch SF1,7226573.8%
Thermocool Smart Touch Sf Uni-Directional Navigation Catheter881143.7%
Thermocool Smart Touch Electrophysiology Catheter71552.8%
Thermocool Smarttouch Uni-Directional Navigation Catheter66304.1%
Thermocool Sf Nav Bi-Directional Catheter60706.3%
Thermocool Smart Touch Bi-Directional Navigation Catheter51208%
Thermocool Smarttouch Sf Bi-Directional Nav Catheter35403.4%
NaviStar ThermoCool673207%
ThermoCool SmartTouch3131002.6%
CryoConsole318151.6%
Thermocool Sf Nav Uni-Directional Catheter29204.1%
Ez Steer Nav Bi-Directional Electrophysiology Catheter18413.8%
Unk Smart Touch Bidirectional21301.4%
Unk Navistar Thermocool22004.5%

Ordered by report count for navigation only. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data." FDA also states that "common products may have a higher number of adverse events due to the higher total number of people using the product."

Questions about Thermocool Smarttouch Bi-Directional Navigation Catheter reports

How many FDA reports name Thermocool Smarttouch Bi-Directional Navigation Catheter?

1,224 medical device reports in the openFDA MAUDE release of 28 Sep 2026, covering reports received through August 2026; 0 in the latest 12 months.

What kinds of events are reported?

injury (65.8%), malfunction (29%) and death (5%). "Event type" is how the report was classified when filed: death, injury, malfunction or other.

What device problems are coded?

insufficient device problem information (22.1%), device operates differently than expected (9.6%), device displays incorrect message (7.8%), break (4.7%) and temperature problem (3.3%). These are FDA's device problem codes as entered on the report.

Who files these reports?

manufacturer reports (99.8%) and voluntary reports (0.2%). Manufacturers and user facilities are required to report; voluntary reports come from health professionals and the public.

Do these reports show that Thermocool Smarttouch Bi-Directional Navigation Catheter was at fault?

No. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data." FDA adds that "a causal relationship cannot be established between product and reactions listed in a report."

How do I report a problem with a medical device?

Through FDA MedWatch (Form FDA 3500 for health professionals and consumers), or to the manufacturer. See the guide on how to report.

Where this comes from. Counts are built from the openFDA Device Adverse Event (MAUDE) bulk export released 28 Sep 2026, which holds reports FDA received through 31 Aug 2026. Brand, generic and manufacturer names are as written on the reports; product code names come from FDA's device classification. A report counts here when any device it lists carries this brand name after punctuation and capitalisation are normalised. No report narrative, lot number, patient detail or reporter identity is published. See the methodology and sources; FDA's record is authoritative, and corrections are handled within five working days.

Drug data (FAERS) through 30 Jun 2026; device data (MAUDE) through 31 Aug 2026. Not medical advice.