Teligen Is-1/Df-1 - Vr: medical device reports filed with FDA

517 reports name it, 2008–2010. Manufacturer given most often on reports: Guidant Crm Clonmel Ireland. Product code LWS.

517
device reports naming the brand
0% of all MAUDE reports · about 29 a year
0
reports, 12 months to August 2026
0 in the 12 months before
51.1%
classified as malfunction
37.4% across the product code
0%
classified as death, as reported
0 reports · not verified by FDA

517 medical device reports received by FDA name the brand "Teligen Is-1/Df-1 - Vr" (implantable cardioverter defibrillator); the manufacturer given most often on reports is Guidant Crm Clonmel Ireland; received from August 2008 to May 2010. Brand names are as the reporter or manufacturer wrote them, so one product can appear under several spellings.

0 reports arrived in the 12 months to August 2026, and none in the 12 months before. FDA releases MAUDE data monthly; reports can arrive months after an event, so the newest months grow in later releases. The event types recorded are malfunction (51.1%), injury (48.5%) and other (0.4%); across all implantable cardioverter defibrillator (non-crt) reports (product code LWS) death is recorded in 2.7% and malfunction in 37.4%. Event type is the reporter's classification of the report, not a verified outcome.

The device problems coded most often are high impedance (26.7%), noise (10.3%) and over-sensing (9.9%). The patient problems coded most often are surgical procedure, repeated, other (for use when an appropriate patient code cannot be identified) and pocket erosion. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data."

Reports by month, five years

No report naming Teligen Is-1/Df-1 - Vr was received in the five years to August 2026; the latest was received in May 2010.

By year received

01262522008: 5620082009: 25220092010: 2092010

Event type and report source

Event type, as classified on the report

Death0%0
Injury48.5%251
Malfunction51.1%264
Other0.4%2
Not given0%0

Who filed the report

Manufacturer report100%517
Voluntary report0%0
User facility report0%0
Distributor report0%0
Not given0%0

Grey bar: all 380,959 reports carrying product code LWS. Event type is the filer's classification and is not verified by FDA.

Device problems coded

Device problem (FDA code)ReportsShareShare across product code
High impedance13826.7%15.6%
Noise5310.3%1.3%
Over-sensing519.9%21.1%
Mechanical problema mechanical problem458.7%1%
Normal458.7%1.8%
Connection error428.1%0.1%
Inappropriate/inadequate shock/stimulation397.5%12.8%
Difficult to insertthe device was hard to insert305.8%0.2%
Loose or intermittent connection285.4%0.3%
Device sensing problem224.3%3.9%
Pacing problem203.9%3.8%
Failure to capture142.7%2.6%
Under-sensing142.7%3.1%
Loss of threshold132.5%0.4%
Device displays incorrect message101.9%1.7%
Malfunction81.5%1.1%
Pacing inadequately81.5%0.1%
Device operates differently than expectedthe device behaved unexpectedly71.4%1.6%
Communication or transmission problemthe device could not communicate or transmit61.2%0.4%
Failure to convert rhythm61.2%0.9%

FDA's device problem codes as entered on the report; one report can carry several. Generic codes such as "no apparent adverse event" are left out.

Patient problems coded

Patient problem (FDA code)ReportsShare
Surgical procedure, repeated265%
Other (for use when an appropriate patient code cannot be identified)152.9%
Pocket erosion91.7%
Surgery, prolonged91.7%
Atrial fibrillationan irregular heart rhythm71.4%
Ventricular tachycardiaa fast rhythm from the lower heart chambers71.4%
Syncopefainting61.2%
Ventricular fibrillationa chaotic rhythm from the lower heart chambers40.8%
Arrhythmia20.4%
Asystole20.4%
Congestive heart failure20.4%
Hematomaa collection of blood under the skin or in tissue20.4%
Cardiac tamponade10.2%
Complaint, ill-defined10.2%
Deaththe patient died; cause not stated by this term10.2%

Patient problem codes are present mainly in reports filed since 2019 and are often blank.

In context

MeasureTeligen Is-1/Df-1 - VrProduct code LWSAll MAUDE reports
Reports517380,95926,136,888
Share of that pool—0.1%0%
Classified as death, per 1,000 reports0279
Classified as injury48.5%59.6%36.2%
Classified as malfunction51.1%37.4%62.3%
Filed by the manufacturer100%97.8%94.9%

Shares are of reports, not of devices in use. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data."

Other brands with product code LWS

BrandReportsLatest 12 monthsClassified as death
Sprint Quattro Secure S MRI SureScan36,8956,4361.4%
Emblem Mri S-Icd21,4803,0880.2%
Sprint Quattro Secure24,23725.2%
Emblem S-Icd17,2502,2370.1%
Sprint Fidelis17,00534014.1%
Sprint Quattro Secure S14,39802.4%
Endotak Reliance25,8972381.2%
Sprint Quattro Secure MRI SureScan15,6061,9031.4%
Endotak Reliance G10,1151,0490.6%
Teligen16,537470.6%
Durata Sts Optim Active Fixation9,6813015.6%
Sprint Quattro5,59102.6%
Reliance 4-Front9,8522,0240.4%
Sprint6,1311612.4%
Vitality 24,77901%

Ordered by report count for navigation only. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data." FDA also states that "common products may have a higher number of adverse events due to the higher total number of people using the product."

Questions about Teligen Is-1/Df-1 - Vr reports

How many FDA reports name Teligen Is-1/Df-1 - Vr?

517 medical device reports in the openFDA MAUDE release of 28 Sep 2026, covering reports received through August 2026; 0 in the latest 12 months.

What kinds of events are reported?

malfunction (51.1%), injury (48.5%) and other (0.4%). "Event type" is how the report was classified when filed: death, injury, malfunction or other.

What device problems are coded?

high impedance (26.7%), noise (10.3%), over-sensing (9.9%), mechanical problem (8.7%) and normal (8.7%). These are FDA's device problem codes as entered on the report.

Who files these reports?

manufacturer reports (100%). Manufacturers and user facilities are required to report; voluntary reports come from health professionals and the public.

Do these reports show that Teligen Is-1/Df-1 - Vr was at fault?

No. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data." FDA adds that "a causal relationship cannot be established between product and reactions listed in a report."

How do I report a problem with a medical device?

Through FDA MedWatch (Form FDA 3500 for health professionals and consumers), or to the manufacturer. See the guide on how to report.

Where this comes from. Counts are built from the openFDA Device Adverse Event (MAUDE) bulk export released 28 Sep 2026, which holds reports FDA received through 31 Aug 2026. Brand, generic and manufacturer names are as written on the reports; product code names come from FDA's device classification. A report counts here when any device it lists carries this brand name after punctuation and capitalisation are normalised. No report narrative, lot number, patient detail or reporter identity is published. See the methodology and sources; FDA's record is authoritative, and corrections are handled within five working days.