Device brand name · Monofocal iols
Tecnis Itec Preloaded 1-Piece Iol: medical device reports filed with FDA
2,435 reports name it, 2013–2021. Manufacturer given most often on reports: Abbott Medical Optics. Product code HQL.
- 2,435
- device reports naming the brand
- 0% of all MAUDE reports · about 180 a year
- 0
- reports, 12 months to August 2026
- 0 in the 12 months before
- 69.2%
- classified as malfunction
- 52.8% across the product code
- 0%
- classified as death, as reported
- 0 reports · not verified by FDA
2,435 medical device reports received by FDA name the brand "Tecnis Itec Preloaded 1-Piece Iol" (monofocal iols); the manufacturer given most often on reports is Abbott Medical Optics; received from January 2013 to July 2021. Brand names are as the reporter or manufacturer wrote them, so one product can appear under several spellings.
0 reports arrived in the 12 months to August 2026, and none in the 12 months before. FDA releases MAUDE data monthly; reports can arrive months after an event, so the newest months grow in later releases. The event types recorded are malfunction (69.2%) and injury (30.8%); across all intraocular lens reports (product code HQL) death is recorded in 0% and malfunction in 52.8%. Event type is the reporter's classification of the report, not a verified outcome.
The device problems coded most often are break (12.1%), crack (8%) and sticking (7.9%). The patient problems coded most often are no patient involvement, capsular bag tear and vitrectomy. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data."
Reports by month, five years
No report naming Tecnis Itec Preloaded 1-Piece Iol was received in the five years to August 2026; the latest was received in July 2021.
By year received
Event type and report source
Event type, as classified on the report
Who filed the report
Grey bar: all 79,755 reports carrying product code HQL. Event type is the filer's classification and is not verified by FDA.
Device problems coded
| Device problem (FDA code) | Reports | Share | Share across product code |
|---|---|---|---|
| Breakthe device broke | 295 | 12.1% | 9.8% |
| Crackthe device cracked | 196 | 8% | 2.8% |
| Sticking | 193 | 7.9% | 1.1% |
| Failure to eject | 190 | 7.8% | 1.1% |
| Difficult or delayed positioning | 184 | 7.6% | 0.3% |
| Positioning failure | 172 | 7.1% | 0.3% |
| Device contamination with chemical or other material | 161 | 6.6% | 1.1% |
| Scratched material | 99 | 4.1% | 3.9% |
| Failure to unfold or unwrap | 81 | 3.3% | 0.7% |
| Contamination | 79 | 3.2% | 0.9% |
| Device operates differently than expectedthe device behaved unexpectedly | 76 | 3.1% | 1% |
| Torn material | 72 | 3% | 1.5% |
| Premature activation | 70 | 2.9% | 0.1% |
| Difficult to fold, unfold or collapse | 67 | 2.8% | 0.7% |
| Material deformation | 56 | 2.3% | 0.5% |
| Physical resistance/sticking | 49 | 2% | 0.4% |
| Split | 47 | 1.9% | 0.2% |
| Failure to advance | 35 | 1.4% | 1.2% |
| Separation problem | 30 | 1.2% | 0.1% |
| Detachment of device component | 29 | 1.2% | 0.5% |
FDA's device problem codes as entered on the report; one report can carry several. Generic codes such as "no apparent adverse event" are left out.
Patient problems coded
| Patient problem (FDA code) | Reports | Share |
|---|---|---|
| No patient involvement | 332 | 13.6% |
| Capsular bag tear | 150 | 6.2% |
| Vitrectomy | 131 | 5.4% |
| Blurred vision | 48 | 2% |
| Visual disturbances | 47 | 1.9% |
| Visual impairmentreduced vision | 33 | 1.4% |
| Corneal edema | 31 | 1.3% |
| Inflammationinflammation | 16 | 0.7% |
| Halo | 15 | 0.6% |
| Endophthalmitisinfection inside the eye | 7 | 0.3% |
| Dry eye(s) | 6 | 0.2% |
| Intraocular pressure increasedraised pressure in the eye | 6 | 0.2% |
| Iritis | 5 | 0.2% |
| Red eye(s) | 5 | 0.2% |
| Discharge | 4 | 0.2% |
Patient problem codes are present mainly in reports filed since 2019 and are often blank.
In context
| Measure | Tecnis Itec Preloaded 1-Piece Iol | Product code HQL | All MAUDE reports |
|---|---|---|---|
| Reports | 2,435 | 79,755 | 26,136,888 |
| Share of that pool | — | 3.1% | 0% |
| Classified as death, per 1,000 reports | 0 | 0 | 9 |
| Classified as injury | 30.8% | 42.8% | 36.2% |
| Classified as malfunction | 69.2% | 52.8% | 62.3% |
| Filed by the manufacturer | 100% | 98.2% | 94.9% |
Shares are of reports, not of devices in use. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data."
Other brands with product code HQL
| Brand | Reports | Latest 12 months | Classified as death |
|---|---|---|---|
| Acrysof | 9,161 | 0 | 0% |
| Tecnis Simplicity | 5,310 | 1,217 | 0% |
| Tecnis Iol | 5,901 | 715 | 0% |
| Tecnis | 3,082 | 0 | 0.1% |
| AcrySof IQ Natural Singlepiece IOL | 2,424 | 118 | 0% |
| Clareon IOL with the AutonoME Delivery System | 2,276 | 864 | 0% |
| Tecnis 1-Piece | 2,259 | 0 | 0% |
| enVista Intraocular Lens | 2,163 | 36 | 0% |
| Hydroview Intraocular Lens | 2,067 | 0 | 0% |
| Acrysof Restor | 3,801 | 0 | 0% |
| Acrysof Iq Toric | 1,905 | 0 | 0% |
| AcrySof Multipiece IOL | 1,619 | 298 | 0% |
| Silicone Advanced Optic-Violet Shield | 1,413 | 0 | 0% |
| AcrySof Singlepiece IOL | 1,211 | 131 | 0% |
| Silicone Ultraviolet-Absorbing Posterior Chamber Three Piece Foldable Intraocula | 1,138 | 0 | 0% |
Ordered by report count for navigation only. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data." FDA also states that "common products may have a higher number of adverse events due to the higher total number of people using the product."
Questions about Tecnis Itec Preloaded 1-Piece Iol reports
How many FDA reports name Tecnis Itec Preloaded 1-Piece Iol?
2,435 medical device reports in the openFDA MAUDE release of 28 Sep 2026, covering reports received through August 2026; 0 in the latest 12 months.
What kinds of events are reported?
malfunction (69.2%) and injury (30.8%). "Event type" is how the report was classified when filed: death, injury, malfunction or other.
What device problems are coded?
break (12.1%), crack (8%), sticking (7.9%), failure to eject (7.8%) and difficult or delayed positioning (7.6%). These are FDA's device problem codes as entered on the report.
Who files these reports?
manufacturer reports (100%). Manufacturers and user facilities are required to report; voluntary reports come from health professionals and the public.
Do these reports show that Tecnis Itec Preloaded 1-Piece Iol was at fault?
No. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data." FDA adds that "a causal relationship cannot be established between product and reactions listed in a report."
How do I report a problem with a medical device?
Through FDA MedWatch (Form FDA 3500 for health professionals and consumers), or to the manufacturer. See the guide on how to report.
Where this comes from. Counts are built from the openFDA Device Adverse Event (MAUDE) bulk export released 28 Sep 2026, which holds reports FDA received through 31 Aug 2026. Brand, generic and manufacturer names are as written on the reports; product code names come from FDA's device classification. A report counts here when any device it lists carries this brand name after punctuation and capitalisation are normalised. No report narrative, lot number, patient detail or reporter identity is published. See the methodology and sources; FDA's record is authoritative, and corrections are handled within five working days.
Drug data (FAERS) through 30 Jun 2026; device data (MAUDE) through 31 Aug 2026. Not medical advice.