Stealthstation Tria Navigation System: medical device reports filed with FDA

173 reports name it, 2010–2019. Manufacturer given most often on reports: Medtronic Navigation. Product code HAW.

173
device reports naming the brand
0% of all MAUDE reports · about 11 a year
0
reports, 12 months to August 2026
0 in the 12 months before
90.8%
classified as malfunction
92.2% across the product code
0.6%
classified as death, as reported
1 reports · not verified by FDA

173 medical device reports received by FDA name the brand "Stealthstation Tria Navigation System" (neurological stereotaxic instrument); the manufacturer given most often on reports is Medtronic Navigation; received from December 2010 to August 2019. Brand names are as the reporter or manufacturer wrote them, so one product can appear under several spellings.

0 reports arrived in the 12 months to August 2026, and none in the 12 months before. FDA releases MAUDE data monthly; reports can arrive months after an event, so the newest months grow in later releases. The event types recorded are malfunction (90.8%), injury (8.7%) and death (0.6%); across all neurological stereotaxic instrument reports (product code HAW) death is recorded in 0.2% and malfunction in 92.2%. Event type is the reporter's classification of the report, not a verified outcome.

The device problems coded most often are device stops intermittently (12.7%), device operates differently than expected (12.1%) and application interface becomes non-functional or program exits abnormally (11.6%). The patient problems coded most often are no patient involvement, iatrogenic source and spinal column injury. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data."

Reports by month, five years

No report naming Stealthstation Tria Navigation System was received in the five years to August 2026; the latest was received in August 2019.

By year received

026512010: 520102011: 5120112012: 1520122013: 2020132014: 1920142015: 1620152016: 1620162017: 1420172018: 1220182019: 52019

Event type and report source

Event type, as classified on the report

Death0.6%1
Injury8.7%15
Malfunction90.8%157
Other0%0
Not given0%0

Who filed the report

Manufacturer report100%173
Voluntary report0%0
User facility report0%0
Distributor report0%0
Not given0%0

Grey bar: all 42,840 reports carrying product code HAW. Event type is the filer's classification and is not verified by FDA.

Device problems coded

Device problem (FDA code)ReportsShareShare across product code
Device stops intermittentlythe device stopped now and then2212.7%2.5%
Device operates differently than expectedthe device behaved unexpectedly2112.1%6.5%
Application interface becomes non-functional or program exits abnormally2011.6%4.4%
Imprecision1911%13%
Unintended arm motion137.5%0.9%
No display/image116.4%1.3%
Unintended movement74%1.1%
Calibration error63.5%0%
Communication or transmission problemthe device could not communicate or transmit63.5%6.4%
Image display error/artifact63.5%0.6%
Computer software problema software problem42.3%4.5%
Device displays incorrect message42.3%1.6%
Positioning problem42.3%0.5%
Application program problem31.7%6.3%
Breakthe device broke31.7%2.9%
Calibration problem31.7%0.3%
Device sensing problem31.7%6.1%
Device slipped31.7%0.3%
Loose or intermittent connection31.7%0.3%
Computer operating system problem21.2%0.4%

FDA's device problem codes as entered on the report; one report can carry several. Generic codes such as "no apparent adverse event" are left out.

Patient problems coded

Patient problem (FDA code)ReportsShare
No patient involvement7744.5%
Iatrogenic source179.8%
Spinal column injury116.4%
Hemorrhage/blood loss/bleeding21.2%
Neurological deficit/dysfunction21.2%
Visual impairmentreduced vision21.2%
Blood loss10.6%
Cerebrospinal fluid leakage10.6%
Deaththe patient died; cause not stated by this term10.6%
Discomfortdiscomfort10.6%
Edemaswelling from fluid10.6%
Hematomaa collection of blood under the skin or in tissue10.6%
Inflammationinflammation10.6%
Muscle weakness/atrophy10.6%
Nauseafeeling sick10.6%

Patient problem codes are present mainly in reports filed since 2019 and are often blank.

In context

MeasureStealthstation Tria Navigation SystemProduct code HAWAll MAUDE reports
Reports17342,84026,136,888
Share of that pool—0.4%0%
Classified as death, per 1,000 reports629
Classified as injury8.7%6.9%36.2%
Classified as malfunction90.8%92.2%62.3%
Filed by the manufacturer100%99.5%94.9%

Shares are of reports, not of devices in use. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data."

Other brands with product code HAW

BrandReportsLatest 12 monthsClassified as death
StealthStation S8 system10,8701,3680.1%
Stealthstation S7 System5,98900.4%
Stealthstation S72,207300.4%
Fusion Navigation System2,16500%
Fusion Ent Navigation System1,52080%
Stealthstation S8 Premium System1,00700%
Stealthstation Treon Treatment Guidance System96100.4%
Cart 9734056 S7 Staff Shrt 100-120v Intl90440%
Rosa Surgical Device71100%
Rosa Brain67500.1%
Rosa One59500%
Medtronic Navigation682696.7%
Stealthstation I7 Integrated Navigation System47100%
Open Spine Clamp Titanium44500%
Stealthstation S7 Navigation36610%

Ordered by report count for navigation only. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data." FDA also states that "common products may have a higher number of adverse events due to the higher total number of people using the product."

Questions about Stealthstation Tria Navigation System reports

How many FDA reports name Stealthstation Tria Navigation System?

173 medical device reports in the openFDA MAUDE release of 28 Sep 2026, covering reports received through August 2026; 0 in the latest 12 months.

What kinds of events are reported?

malfunction (90.8%), injury (8.7%) and death (0.6%). "Event type" is how the report was classified when filed: death, injury, malfunction or other.

What device problems are coded?

device stops intermittently (12.7%), device operates differently than expected (12.1%), application interface becomes non-functional or program exits abnormally (11.6%), imprecision (11%) and unintended arm motion (7.5%). These are FDA's device problem codes as entered on the report.

Who files these reports?

manufacturer reports (100%). Manufacturers and user facilities are required to report; voluntary reports come from health professionals and the public.

Do these reports show that Stealthstation Tria Navigation System was at fault?

No. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data." FDA adds that "a causal relationship cannot be established between product and reactions listed in a report."

How do I report a problem with a medical device?

Through FDA MedWatch (Form FDA 3500 for health professionals and consumers), or to the manufacturer. See the guide on how to report.

Where this comes from. Counts are built from the openFDA Device Adverse Event (MAUDE) bulk export released 28 Sep 2026, which holds reports FDA received through 31 Aug 2026. Brand, generic and manufacturer names are as written on the reports; product code names come from FDA's device classification. A report counts here when any device it lists carries this brand name after punctuation and capitalisation are normalised. No report narrative, lot number, patient detail or reporter identity is published. See the methodology and sources; FDA's record is authoritative, and corrections are handled within five working days.

Drug data (FAERS) through 30 Jun 2026; device data (MAUDE) through 31 Aug 2026. Not medical advice.