Reported Reactions

Devices › Stents, drains and dilators for the biliary ducts

Device brand name · Catheter biliary diagnostic

Rx Biliary: medical device reports filed with FDA

194 reports name it, 2011–2026. Manufacturer given most often on reports: Boston Scientific - Spencer. Product code FGE.

194
device reports naming the brand
0% of all MAUDE reports · about 13 a year
5
reports, 12 months to August 2026
2 in the 12 months before
35.1%
classified as malfunction
69% across the product code
0%
classified as death, as reported
0 reports · not verified by FDA

194 medical device reports received by FDA name the brand "Rx Biliary" (catheter biliary diagnostic); the manufacturer given most often on reports is Boston Scientific - Spencer; received from July 2011 to June 2026. Brand names are as the reporter or manufacturer wrote them, so one product can appear under several spellings.

5 reports arrived in the 12 months to August 2026, up 150% from 2 in the 12 months before. FDA releases MAUDE data monthly; reports can arrive months after an event, so the newest months grow in later releases. The event types recorded are injury (64.9%) and malfunction (35.1%); across all stents, drains and dilators for the biliary ducts reports (product code FGE) death is recorded in 1.1% and malfunction in 69%. Event type is the reporter's classification of the report, not a verified outcome.

The device problems coded most often are break (63.9%), material deformation (7.2%) and kinked (1.5%). The patient problems coded most often are no patient involvement, device embedded in tissue or plaque and discomfort. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data."

Reports by month, five years

023Sep 2021: 0Oct 2021: 2Nov 2021: 1Dec 2021: 22022Jan 2022: 1Feb 2022: 3Mar 2022: 0Apr 2022: 0May 2022: 0Jun 2022: 0Jul 2022: 2Aug 2022: 0Sep 2022: 0Oct 2022: 0Nov 2022: 0Dec 2022: 12023Jan 2023: 0Feb 2023: 0Mar 2023: 0Apr 2023: 0May 2023: 0Jun 2023: 0Jul 2023: 0Aug 2023: 0Sep 2023: 0Oct 2023: 0Nov 2023: 0Dec 2023: 02024Jan 2024: 0Feb 2024: 1Mar 2024: 0Apr 2024: 2May 2024: 0Jun 2024: 0Jul 2024: 0Aug 2024: 0Sep 2024: 0Oct 2024: 0Nov 2024: 1Dec 2024: 12025Jan 2025: 0Feb 2025: 0Mar 2025: 0Apr 2025: 0May 2025: 0Jun 2025: 0Jul 2025: 0Aug 2025: 0Sep 2025: 0Oct 2025: 0Nov 2025: 0Dec 2025: 02026Jan 2026: 0Feb 2026: 0Mar 2026: 0Apr 2026: 2May 2026: 0Jun 2026: 3Jul 2026: 0Aug 2026: 0

Reports by the month FDA received them. FDA releases MAUDE data monthly; reports can arrive months after an event, so the newest months grow in later releases.

By year received

017342011: 1120112012: 202013: 1220132014: 172015: 3420152016: 302017: 1320172018: 52019: 1220192020: 122021: 1120212022: 72024: 520242026: 5

Event type and report source

Event type, as classified on the report

Death0%0
Injury64.9%126
Malfunction35.1%68
Other0%0
Not given0%0

Who filed the report

Manufacturer report98.5%191
Voluntary report0%0
User facility report0%0
Distributor report0%0
Not given1.5%3

Grey bar: all 33,832 reports carrying product code FGE. Event type is the filer's classification and is not verified by FDA.

Device problems coded

Device problem (FDA code)ReportsShareShare across product code
Breakthe device broke12463.9%9.7%
Material deformation147.2%3.9%
Kinkedthe tube or line kinked31.5%1.4%
Bent21%0.9%
Collapse21%0.1%
Device contamination with chemical or other material10.5%0.3%
Device fell10.5%0%
Device packaging compromised10.5%0.1%
Material twisted/bent10.5%1.1%
Migration or expulsion of device10.5%3.3%
Premature activation10.5%3.9%

FDA's device problem codes as entered on the report; one report can carry several. Generic codes such as "no apparent adverse event" are left out.

Patient problems coded

Patient problem (FDA code)ReportsShare
No patient involvement84.1%
Device embedded in tissue or plaque10.5%
Discomfortdiscomfort10.5%
Perforation10.5%

Patient problem codes are present mainly in reports filed since 2019 and are often blank.

In context

MeasureRx BiliaryProduct code FGEAll MAUDE reports
Reports19433,83226,136,888
Share of that pool—0.6%0%
Classified as death, per 1,000 reports0119
Classified as injury64.9%29%36.2%
Classified as malfunction35.1%69%62.3%
Filed by the manufacturer98.5%97.5%94.9%

Shares are of reports, not of devices in use. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data."

Other brands with product code FGE

BrandReportsLatest 12 monthsClassified as death
Mustang5,9694910.3%
Hurricane RX1,227510.2%
Cre Pro9853410.1%
Advanix Biliary872750.9%
WallFlex Biliary RX Stent System774252.2%
Absolute Pro .035 Self Expanding Stent System858380.2%
Zimmon Biliary Stent665450%
Smart Control Nitinol Stent System1,43801.7%
Evolution Biliary Controlled-Release Stent - Fully Covered600990.2%
WallFlex Biliary834561.8%
Zimmon Biliary Stent Set530340%
Express LD Vascular520470%
Extractor Rx Retrieval Balloon49900.6%
Flexima Biliary485340%
Zilver 635 Biliary Self Expanding Metal Stent362130%

Ordered by report count for navigation only. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data." FDA also states that "common products may have a higher number of adverse events due to the higher total number of people using the product."

Questions about Rx Biliary reports

How many FDA reports name Rx Biliary?

194 medical device reports in the openFDA MAUDE release of 28 Sep 2026, covering reports received through August 2026; 5 in the latest 12 months.

What kinds of events are reported?

injury (64.9%) and malfunction (35.1%). "Event type" is how the report was classified when filed: death, injury, malfunction or other.

What device problems are coded?

break (63.9%), material deformation (7.2%), kinked (1.5%), bent (1%) and collapse (1%). These are FDA's device problem codes as entered on the report.

Who files these reports?

manufacturer reports (98.5%). Manufacturers and user facilities are required to report; voluntary reports come from health professionals and the public.

Do these reports show that Rx Biliary was at fault?

No. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data." FDA adds that "a causal relationship cannot be established between product and reactions listed in a report."

How do I report a problem with a medical device?

Through FDA MedWatch (Form FDA 3500 for health professionals and consumers), or to the manufacturer. See the guide on how to report.

Where this comes from. Counts are built from the openFDA Device Adverse Event (MAUDE) bulk export released 28 Sep 2026, which holds reports FDA received through 31 Aug 2026. Brand, generic and manufacturer names are as written on the reports; product code names come from FDA's device classification. A report counts here when any device it lists carries this brand name after punctuation and capitalisation are normalised. No report narrative, lot number, patient detail or reporter identity is published. See the methodology and sources; FDA's record is authoritative, and corrections are handled within five working days.

Drug data (FAERS) through 30 Jun 2026; device data (MAUDE) through 31 Aug 2026. Not medical advice.