Reported Reactions

Devices › Device, neurovascular embolization

Device brand name · Hcg krd

Penumbra Smart Coil Detachment Handle: medical device reports filed with FDA

317 reports name it, 2015–2021. Manufacturer given most often on reports: Penumbra. Product code HCG.

317
device reports naming the brand
0% of all MAUDE reports · about 29 a year
0
reports, 12 months to August 2026
0 in the 12 months before
100%
classified as malfunction
73% across the product code
0%
classified as death, as reported
0 reports · not verified by FDA

317 medical device reports received by FDA name the brand "Penumbra Smart Coil Detachment Handle" (hcg krd); the manufacturer given most often on reports is Penumbra; received from June 2015 to December 2021. Brand names are as the reporter or manufacturer wrote them, so one product can appear under several spellings.

0 reports arrived in the 12 months to August 2026, and none in the 12 months before. FDA releases MAUDE data monthly; reports can arrive months after an event, so the newest months grow in later releases. The event types recorded are malfunction (100%); across all device, neurovascular embolization reports (product code HCG) death is recorded in 2.4% and malfunction in 73%. Event type is the reporter's classification of the report, not a verified outcome.

The device problems coded most often are mechanical problem (87.1%), device operates differently than expected (17.4%) and separation failure (6%). The patient problems coded most often are no patient involvement. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data."

Reports by month, five years

0816Sep 2021: 6Oct 2021: 16Nov 2021: 13Dec 2021: 42022Jan 2022: 0Feb 2022: 0Mar 2022: 0Apr 2022: 0May 2022: 0Jun 2022: 0Jul 2022: 0Aug 2022: 0Sep 2022: 0Oct 2022: 0Nov 2022: 0Dec 2022: 02023Jan 2023: 0Feb 2023: 0Mar 2023: 0Apr 2023: 0May 2023: 0Jun 2023: 0Jul 2023: 0Aug 2023: 0Sep 2023: 0Oct 2023: 0Nov 2023: 0Dec 2023: 02024Jan 2024: 0Feb 2024: 0Mar 2024: 0Apr 2024: 0May 2024: 0Jun 2024: 0Jul 2024: 0Aug 2024: 0Sep 2024: 0Oct 2024: 0Nov 2024: 0Dec 2024: 02025Jan 2025: 0Feb 2025: 0Mar 2025: 0Apr 2025: 0May 2025: 0Jun 2025: 0Jul 2025: 0Aug 2025: 0Sep 2025: 0Oct 2025: 0Nov 2025: 0Dec 2025: 02026Jan 2026: 0Feb 2026: 0Mar 2026: 0Apr 2026: 0May 2026: 0Jun 2026: 0Jul 2026: 0Aug 2026: 0

Reports by the month FDA received them. FDA releases MAUDE data monthly; reports can arrive months after an event, so the newest months grow in later releases.

By year received

040792015: 820152016: 1020162017: 6520172018: 5020182019: 5420192020: 5120202021: 792021

Event type and report source

Event type, as classified on the report

Death0%0
Injury0%0
Malfunction100%317
Other0%0
Not given0%0

Who filed the report

Manufacturer report100%317
Voluntary report0%0
User facility report0%0
Distributor report0%0
Not given0%0

Grey bar: all 26,252 reports carrying product code HCG. Event type is the filer's classification and is not verified by FDA.

Device problems coded

Device problem (FDA code)ReportsShareShare across product code
Mechanical problema mechanical problem27687.1%2%
Device operates differently than expectedthe device behaved unexpectedly5517.4%1.8%
Separation failure196%3.8%
Difficult or delayed activation82.5%0.5%
Device handling problem30.9%1.1%
Noise, audible30.9%0%
Breakthe device broke20.6%5.7%
Device damaged prior to usethe device was damaged before use20.6%1.1%
Physical resistance/sticking20.6%9.9%
Contamination10.3%0.1%
Detachment of device or device componentpart of the device came off10.3%2.6%
Device operational issue10.3%0.1%
Difficult to removethe device was hard to remove10.3%2%
Fracturea broken bone10.3%2.3%
Material separation10.3%1%
Mechanical jam10.3%1.2%
Out-of-box failure10.3%0.6%
Positioning failure10.3%4.7%
Separation problem10.3%0.2%

FDA's device problem codes as entered on the report; one report can carry several. Generic codes such as "no apparent adverse event" are left out.

Patient problems coded

Patient problem (FDA code)ReportsShare
No patient involvement61.9%

Patient problem codes are present mainly in reports filed since 2019 and are often blank.

In context

MeasurePenumbra Smart Coil Detachment HandleProduct code HCGAll MAUDE reports
Reports31726,25226,136,888
Share of that pool—1.2%0%
Classified as death, per 1,000 reports0249
Classified as injury0%24%36.2%
Classified as malfunction100%73%62.3%
Filed by the manufacturer100%98.5%94.9%

Shares are of reports, not of devices in use. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data."

Other brands with product code HCG

BrandReportsLatest 12 monthsClassified as death
Ruby Coil3,360260.1%
Penumbra Smart Coil2,78130.3%
Penumbra Coil 4001,45300.9%
POD Packing Coil1,062350%
Trufill Dcs Orbit Mini Complex Fill73501.6%
Ruby Coil Lp479130%
Pod406180%
Trufill Dcs Orbit Detachable Coils Complex39500.8%
Deltaplush - Cerecyte Microcoil39200.3%
Deltapaq - Cerecyte Microcoil29500%
Orbit Galaxy Detachable Coil System27300.4%
Optima Coil System255552%
Packing Coil LP235110%
Xtrasoft Orbit Galaxy Detachable Coil23501.3%
Axium 3-D Detachable Coil22200.5%

Ordered by report count for navigation only. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data." FDA also states that "common products may have a higher number of adverse events due to the higher total number of people using the product."

Questions about Penumbra Smart Coil Detachment Handle reports

How many FDA reports name Penumbra Smart Coil Detachment Handle?

317 medical device reports in the openFDA MAUDE release of 28 Sep 2026, covering reports received through August 2026; 0 in the latest 12 months.

What kinds of events are reported?

malfunction (100%). "Event type" is how the report was classified when filed: death, injury, malfunction or other.

What device problems are coded?

mechanical problem (87.1%), device operates differently than expected (17.4%), separation failure (6%), difficult or delayed activation (2.5%) and device handling problem (0.9%). These are FDA's device problem codes as entered on the report.

Who files these reports?

manufacturer reports (100%). Manufacturers and user facilities are required to report; voluntary reports come from health professionals and the public.

Do these reports show that Penumbra Smart Coil Detachment Handle was at fault?

No. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data." FDA adds that "a causal relationship cannot be established between product and reactions listed in a report."

How do I report a problem with a medical device?

Through FDA MedWatch (Form FDA 3500 for health professionals and consumers), or to the manufacturer. See the guide on how to report.

Where this comes from. Counts are built from the openFDA Device Adverse Event (MAUDE) bulk export released 28 Sep 2026, which holds reports FDA received through 31 Aug 2026. Brand, generic and manufacturer names are as written on the reports; product code names come from FDA's device classification. A report counts here when any device it lists carries this brand name after punctuation and capitalisation are normalised. No report narrative, lot number, patient detail or reporter identity is published. See the methodology and sources; FDA's record is authoritative, and corrections are handled within five working days.

Drug data (FAERS) through 30 Jun 2026; device data (MAUDE) through 31 Aug 2026. Not medical advice.