Paradigm Real-Time Insulin Infusion Pump Mmt-754cas: medical device reports filed with FDA

556 reports name it, 2017–2025. Manufacturer given most often on reports: Medtronic Puerto Rico Operations. Product code OYC.

556
device reports naming the brand
0% of all MAUDE reports · about 61 a year
5
reports, 12 months to August 2026
6 in the 12 months before
98%
classified as malfunction
85.5% across the product code
0%
classified as death, as reported
0 reports · not verified by FDA

556 medical device reports received by FDA name the brand "Paradigm Real-Time Insulin Infusion Pump Mmt-754cas" (pump infusion insulin to be used with invasive glucose sensor); the manufacturer given most often on reports is Medtronic Puerto Rico Operations; received from May 2017 to December 2025. Brand names are as the reporter or manufacturer wrote them, so one product can appear under several spellings.

5 reports arrived in the 12 months to August 2026, down 17% from 6 in the 12 months before. FDA releases MAUDE data monthly; reports can arrive months after an event, so the newest months grow in later releases. The event types recorded are malfunction (98%) and injury (2%); across all pump, infusion, insulin, to be used with invasive glucose sensor reports (product code OYC) death is recorded in 0.3% and malfunction in 85.5%. Event type is the reporter's classification of the report, not a verified outcome.

The device problems coded most often are device difficult to program or calibrate (29.3%), mechanical problem (12.6%) and device displays incorrect message (9.9%). The patient problems coded most often are hyperglycemia, hypoglycemia and abdominal pain. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data."

Reports by month, five years

0815Sep 2021: 1Oct 2021: 2Nov 2021: 1Dec 2021: 52022Jan 2022: 1Feb 2022: 3Mar 2022: 15Apr 2022: 3May 2022: 2Jun 2022: 2Jul 2022: 4Aug 2022: 2Sep 2022: 2Oct 2022: 2Nov 2022: 0Dec 2022: 42023Jan 2023: 1Feb 2023: 8Mar 2023: 4Apr 2023: 0May 2023: 1Jun 2023: 1Jul 2023: 0Aug 2023: 3Sep 2023: 2Oct 2023: 0Nov 2023: 0Dec 2023: 12024Jan 2024: 0Feb 2024: 0Mar 2024: 2Apr 2024: 1May 2024: 1Jun 2024: 0Jul 2024: 2Aug 2024: 2Sep 2024: 1Oct 2024: 1Nov 2024: 0Dec 2024: 22025Jan 2025: 0Feb 2025: 0Mar 2025: 0Apr 2025: 0May 2025: 2Jun 2025: 0Jul 2025: 0Aug 2025: 0Sep 2025: 1Oct 2025: 0Nov 2025: 2Dec 2025: 22026Jan 2026: 0Feb 2026: 0Mar 2026: 0Apr 2026: 0May 2026: 0Jun 2026: 0Jul 2026: 0Aug 2026: 0

Reports by the month FDA received them. FDA releases MAUDE data monthly; reports can arrive months after an event, so the newest months grow in later releases.

By year received

0791572017: 6020172018: 9020182019: 15720192020: 12020202021: 4920212022: 4020222023: 2120232024: 1220242025: 72025

Event type and report source

Event type, as classified on the report

Death0%0
Injury2%11
Malfunction98%545
Other0%0
Not given0%0

Who filed the report

Manufacturer report100%556
Voluntary report0%0
User facility report0%0
Distributor report0%0
Not given0%0

Grey bar: all 891,173 reports carrying product code OYC. Event type is the filer's classification and is not verified by FDA.

Device problems coded

Device problem (FDA code)ReportsShareShare across product code
Device difficult to program or calibrate16329.3%2.8%
Mechanical problema mechanical problem7012.6%3.7%
Device displays incorrect message559.9%24%
No display/image488.6%5%
Failure to cycle478.5%0.7%
Breakthe device broke366.5%10.1%
Power problem295.2%4.9%
Detachment of device or device componentpart of the device came off285%0.6%
Obstruction of flow162.9%3%
Patient device interaction problem132.3%7.9%
Priming problem122.2%0.4%
Moisture or humidity problem112%1.7%
Device alarm system91.6%2.4%
Display or visual feedback problem71.3%0.9%
Device inoperablethe device could not be used61.1%2.7%
Fluid/blood leak61.1%0.4%
Insufficient flow or under infusion61.1%0.7%
Premature discharge of battery61.1%0.8%
Visual prompts will not clear61.1%0.7%
Crackthe device cracked50.9%2.2%

FDA's device problem codes as entered on the report; one report can carry several. Generic codes such as "no apparent adverse event" are left out.

Patient problems coded

Patient problem (FDA code)ReportsShare
Hyperglycemiahigh blood sugar478.5%
Hypoglycemialow blood sugar30.5%
Abdominal painstomach or belly pain20.4%
Elevated ketones/ diabetic ketoacidosis20.4%
Brain injury10.2%
Dizzinesslight-headedness or unsteadiness10.2%
Fatiguetiredness10.2%
Nauseafeeling sick10.2%
Vomitingbeing sick10.2%

Patient problem codes are present mainly in reports filed since 2019 and are often blank.

In context

MeasureParadigm Real-Time Insulin Infusion Pump Mmt-754casProduct code OYCAll MAUDE reports
Reports556891,17326,136,888
Share of that pool—0.1%0%
Classified as death, per 1,000 reports039
Classified as injury2%14.2%36.2%
Classified as malfunction98%85.5%62.3%
Filed by the manufacturer100%100%94.9%

Shares are of reports, not of devices in use. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data."

Other brands with product code OYC

BrandReportsLatest 12 monthsClassified as death
Paradigm Real-Time Revel Insulin Infusion Pump178,69100.6%
Paradigm Real-Time Insulin Infusion Pump126,28200.3%
640G Insulin Pump MMT-1712K119,5471,5980.1%
640G Insulin Pump MMT-1711K76,6091510.1%
Animas Vibe88,70300%
T Slim G5 System49,78300%
t:slim G4 system39,215200%
Pump Mmt-1712kl 640g V4 10 Bk Sf Mg21,5319520%
640g Insulin Pump16,91100%
Paradigm REAL-Time REVEL Insulin Infusion Pump MMT-723LNAS12,936410.8%
t:slim X2 Insulin Pump31,159860%
Pump Mmt-1711kl 640g V4 10 Bk Sf Mm11,1571680%
Paradigm REAL-Time Insulin Infusion Pump MMT-754WWS10,4656610%
Paradigm Real-Time Revel Insulin Infusion Pump Mmt-723nas8,540490.8%
640g Insulin Pump Mmt-1712b5,62910%

Ordered by report count for navigation only. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data." FDA also states that "common products may have a higher number of adverse events due to the higher total number of people using the product."

Questions about Paradigm Real-Time Insulin Infusion Pump Mmt-754cas reports

How many FDA reports name Paradigm Real-Time Insulin Infusion Pump Mmt-754cas?

556 medical device reports in the openFDA MAUDE release of 28 Sep 2026, covering reports received through August 2026; 5 in the latest 12 months.

What kinds of events are reported?

malfunction (98%) and injury (2%). "Event type" is how the report was classified when filed: death, injury, malfunction or other.

What device problems are coded?

device difficult to program or calibrate (29.3%), mechanical problem (12.6%), device displays incorrect message (9.9%), no display/image (8.6%) and failure to cycle (8.5%). These are FDA's device problem codes as entered on the report.

Who files these reports?

manufacturer reports (100%). Manufacturers and user facilities are required to report; voluntary reports come from health professionals and the public.

Do these reports show that Paradigm Real-Time Insulin Infusion Pump Mmt-754cas was at fault?

No. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data." FDA adds that "a causal relationship cannot be established between product and reactions listed in a report."

How do I report a problem with a medical device?

Through FDA MedWatch (Form FDA 3500 for health professionals and consumers), or to the manufacturer. See the guide on how to report.

Where this comes from. Counts are built from the openFDA Device Adverse Event (MAUDE) bulk export released 28 Sep 2026, which holds reports FDA received through 31 Aug 2026. Brand, generic and manufacturer names are as written on the reports; product code names come from FDA's device classification. A report counts here when any device it lists carries this brand name after punctuation and capitalisation are normalised. No report narrative, lot number, patient detail or reporter identity is published. See the methodology and sources; FDA's record is authoritative, and corrections are handled within five working days.