Reported Reactions

Devices › Mitral valve repair devices

Device brand name · Valve repair

Mitraclip Ntr Clip Delivery System: medical device reports filed with FDA

455 reports name it, 2020–2023. Manufacturer given most often on reports: Abbott Vascular. Product code NKM.

455
device reports naming the brand
0% of all MAUDE reports · about 72 a year
0
reports, 12 months to August 2026
0 in the 12 months before
39.8%
classified as malfunction
33.6% across the product code
4.4%
classified as death, as reported
20 reports · not verified by FDA

FDA's MAUDE database holds 455 reports that name the brand "Mitraclip Ntr Clip Delivery System" (valve repair), received between March 2020 and September 2023; the manufacturer given most often on reports is Abbott Vascular. Spellings of one product vary from report to report.

0 reports arrived in the 12 months to August 2026, and none in the 12 months before. FDA releases MAUDE data monthly; reports can arrive months after an event, so the newest months grow in later releases. The event types recorded are injury (55.8%), malfunction (39.8%) and death (4.4%); across all mitral valve repair devices reports (product code NKM) death is recorded in 7% and malfunction in 33.6%. Event type is the reporter's classification of the report, not a verified outcome.

The device problems coded most often are incomplete coaptation (29.2%), difficult to open or close (16.3%) and unintended movement (11.9%). The patient problems coded most often are tissue damage, mitral regurgitation and mitral valve insufficiency/ regurgitation. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data."

Reports by month, five years

036Sep 2021: 6Oct 2021: 2Nov 2021: 4Dec 2021: 42022Jan 2022: 2Feb 2022: 2Mar 2022: 5Apr 2022: 3May 2022: 3Jun 2022: 1Jul 2022: 2Aug 2022: 0Sep 2022: 1Oct 2022: 1Nov 2022: 5Dec 2022: 12023Jan 2023: 1Feb 2023: 0Mar 2023: 2Apr 2023: 1May 2023: 1Jun 2023: 2Jul 2023: 3Aug 2023: 1Sep 2023: 3Oct 2023: 0Nov 2023: 0Dec 2023: 02024Jan 2024: 0Feb 2024: 0Mar 2024: 0Apr 2024: 0May 2024: 0Jun 2024: 0Jul 2024: 0Aug 2024: 0Sep 2024: 0Oct 2024: 0Nov 2024: 0Dec 2024: 02025Jan 2025: 0Feb 2025: 0Mar 2025: 0Apr 2025: 0May 2025: 0Jun 2025: 0Jul 2025: 0Aug 2025: 0Sep 2025: 0Oct 2025: 0Nov 2025: 0Dec 2025: 02026Jan 2026: 0Feb 2026: 0Mar 2026: 0Apr 2026: 0May 2026: 0Jun 2026: 0Jul 2026: 0Aug 2026: 0

Reports by the month FDA received them. FDA releases MAUDE data monthly; reports can arrive months after an event, so the newest months grow in later releases.

By year received

01422842020: 28420202021: 13120212022: 2620222023: 142023

Event type and report source

Event type, as classified on the report

Death4.4%20
Injury55.8%254
Malfunction39.8%181
Other0%0
Not given0%0

Who filed the report

Manufacturer report100%455
Voluntary report0%0
User facility report0%0
Distributor report0%0
Not given0%0

Grey bar: all 25,635 reports carrying product code NKM. Event type is the filer's classification and is not verified by FDA.

Device problems coded

Device problem (FDA code)ReportsShareShare across product code
Incomplete coaptation13329.2%24.2%
Difficult to open or close7416.3%12.2%
Unintended movement5411.9%13.1%
Positioning failure378.1%4.4%
Difficult to removethe device was hard to remove337.3%6.5%
Improper or incorrect procedure or method316.8%4%
Breakthe device broke255.5%2.8%
Difficult or delayed positioning255.5%5.9%
Mechanical jam235.1%2.5%
Leak/splashthe device leaked194.2%2.1%
Device damaged by another device184%3.3%
Migrationthe device moved from where it was placed184%3.4%
Physical resistance/sticking163.5%2%
Entrapment of device153.3%3.5%
Material deformation92%0.8%
Product quality problem92%0.4%
Expulsion61.3%1.4%
Material separation61.3%0.9%
Difficult to insertthe device was hard to insert51.1%0.7%
Material split, cut or torn51.1%0.5%

FDA's device problem codes as entered on the report; one report can carry several. Generic codes such as "no apparent adverse event" are left out.

Patient problems coded

Patient problem (FDA code)ReportsShare
Tissue damage7215.8%
Mitral regurgitation5913%
Mitral valve insufficiency/ regurgitation5011%
No patient involvement296.4%
Dyspneashortness of breath204.4%
Foreign body in patientpart of a device left in the patient194.2%
Mitral valve stenosis163.5%
Pericardial effusionfluid around the heart153.3%
Heart failure/congestive heart failure112.4%
Deaththe patient died; cause not stated by this term102.2%
Low blood pressure/ hypotension92%
Hemorrhage/blood loss/bleeding81.8%
Heart failure71.5%
Cardiac tamponade51.1%
Tachycardiafast heart rate51.1%

Patient problem codes are present mainly in reports filed since 2019 and are often blank.

In context

MeasureMitraclip Ntr Clip Delivery SystemProduct code NKMAll MAUDE reports
Reports45525,63526,136,888
Share of that pool—1.8%0%
Classified as death, per 1,000 reports44709
Classified as injury55.8%59.4%36.2%
Classified as malfunction39.8%33.6%62.3%
Filed by the manufacturer100%99.7%94.9%

Shares are of reports, not of devices in use. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data."

Other brands with product code NKM

BrandReportsLatest 12 monthsClassified as death
MITRACLIP SYSTEM Clip Delivery System5,44529914.9%
Mitraclip G4 Clip Delivery System5,21602.3%
Mitraclip3,3571,1612%
Mitraclip System Clip Delivery System Nt2,30904.6%
MitraClip G4 Clip Delivery System (MDR)2,0652092.1%
Edwards Pascal Precision1,9091,39516.4%
MitraClip G5 Delivery System1,4081,3351.4%
Mitraclip G4 Clip Delivery System Mdd1,19303.2%
Mitraclip Xtr Delivery System1,05004.8%
Mitraclip Xtr Clip Delivery System69903.3%
Mitraclip Ntr Delivery System57102.6%
Mitraclip Clip Delivery System338038.5%
Abbott26507.5%
MitraClip G5 Steerable Guide Catheter3683630.5%
Mitraclip System Steerable Guide Catheter1,528163%

Ordered by report count for navigation only. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data." FDA also states that "common products may have a higher number of adverse events due to the higher total number of people using the product."

Questions about Mitraclip Ntr Clip Delivery System reports

How many FDA reports name Mitraclip Ntr Clip Delivery System?

455 medical device reports in the openFDA MAUDE release of 28 Sep 2026, covering reports received through August 2026; 0 in the latest 12 months.

What kinds of events are reported?

injury (55.8%), malfunction (39.8%) and death (4.4%). "Event type" is how the report was classified when filed: death, injury, malfunction or other.

What device problems are coded?

incomplete coaptation (29.2%), difficult to open or close (16.3%), unintended movement (11.9%), positioning failure (8.1%) and difficult to remove (7.3%). These are FDA's device problem codes as entered on the report.

Who files these reports?

manufacturer reports (100%). Manufacturers and user facilities are required to report; voluntary reports come from health professionals and the public.

Do these reports show that Mitraclip Ntr Clip Delivery System was at fault?

No. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data." FDA adds that "a causal relationship cannot be established between product and reactions listed in a report."

How do I report a problem with a medical device?

Through FDA MedWatch (Form FDA 3500 for health professionals and consumers), or to the manufacturer. See the guide on how to report.

Where this comes from. Counts are built from the openFDA Device Adverse Event (MAUDE) bulk export released 28 Sep 2026, which holds reports FDA received through 31 Aug 2026. Brand, generic and manufacturer names are as written on the reports; product code names come from FDA's device classification. A report counts here when any device it lists carries this brand name after punctuation and capitalisation are normalised. No report narrative, lot number, patient detail or reporter identity is published. See the methodology and sources; FDA's record is authoritative, and corrections are handled within five working days.

Drug data (FAERS) through 30 Jun 2026; device data (MAUDE) through 31 Aug 2026. Not medical advice.