Reported Reactions

Devices › Permanent defibrillator electrodes

Device brand name · Icd lead

Linox Smart SD 60/16: medical device reports filed with FDA

401 reports name it, 2011–2026. Manufacturer given most often on reports: Biotronik Se & Kg. Product code NVY.

401
device reports naming the brand
0% of all MAUDE reports · about 26 a year
22
reports, 12 months to August 2026
19 in the 12 months before
60.3%
classified as malfunction
41.2% across the product code
1.5%
classified as death, as reported
6 reports · not verified by FDA

401 medical device reports received by FDA name the brand "Linox Smart SD 60/16" (icd lead); the manufacturer given most often on reports is Biotronik Se & Kg; received from May 2011 to July 2026. Brand names are as the reporter or manufacturer wrote them, so one product can appear under several spellings.

22 reports arrived in the 12 months to August 2026, up 16% from 19 in the 12 months before. FDA releases MAUDE data monthly; reports can arrive months after an event, so the newest months grow in later releases. The event types recorded are malfunction (60.3%), injury (38.2%) and death (1.5%); across all permanent defibrillator electrodes reports (product code NVY) death is recorded in 2.2% and malfunction in 41.2%. Event type is the reporter's classification of the report, not a verified outcome.

The device problems coded most often are ambient noise problem (39.2%), high impedance (14.2%) and inappropriate/inadequate shock/stimulation (13%). The patient problems coded most often are shock from patient lead(s), twiddlers syndrome and death. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data."

Reports by month, five years

024Sep 2021: 1Oct 2021: 3Nov 2021: 3Dec 2021: 32022Jan 2022: 0Feb 2022: 2Mar 2022: 2Apr 2022: 3May 2022: 0Jun 2022: 3Jul 2022: 2Aug 2022: 4Sep 2022: 2Oct 2022: 0Nov 2022: 1Dec 2022: 12023Jan 2023: 2Feb 2023: 0Mar 2023: 1Apr 2023: 0May 2023: 1Jun 2023: 1Jul 2023: 2Aug 2023: 1Sep 2023: 2Oct 2023: 1Nov 2023: 2Dec 2023: 02024Jan 2024: 2Feb 2024: 4Mar 2024: 1Apr 2024: 4May 2024: 0Jun 2024: 0Jul 2024: 4Aug 2024: 2Sep 2024: 0Oct 2024: 2Nov 2024: 2Dec 2024: 22025Jan 2025: 2Feb 2025: 2Mar 2025: 1Apr 2025: 1May 2025: 3Jun 2025: 1Jul 2025: 1Aug 2025: 2Sep 2025: 3Oct 2025: 1Nov 2025: 3Dec 2025: 32026Jan 2026: 2Feb 2026: 2Mar 2026: 4Apr 2026: 1May 2026: 0Jun 2026: 2Jul 2026: 1Aug 2026: 0

Reports by the month FDA received them. FDA releases MAUDE data monthly; reports can arrive months after an event, so the newest months grow in later releases.

By year received

019382011: 1620112012: 222013: 3220132014: 232015: 2420152016: 352017: 3420172018: 382019: 3220192020: 252021: 2920212022: 202023: 1320232024: 232025: 2320252026: 12

Event type and report source

Event type, as classified on the report

Death1.5%6
Injury38.2%153
Malfunction60.3%242
Other0%0
Not given0%0

Who filed the report

Manufacturer report100%401
Voluntary report0%0
User facility report0%0
Distributor report0%0
Not given0%0

Grey bar: all 138,578 reports carrying product code NVY. Event type is the filer's classification and is not verified by FDA.

Device problems coded

Device problem (FDA code)ReportsShareShare across product code
Ambient noise problem15739.2%3.7%
High impedance5714.2%20%
Inappropriate/inadequate shock/stimulation5213%8.5%
Device dislodged or dislocated4812%10.9%
Fracturea broken bone4310.7%5.4%
Over-sensing338.2%22.8%
Impedance problem205%3.1%
Insufficient device problem information184.5%2.1%
High capture threshold174.2%8.1%
Failure to capture112.7%8.1%
Breakthe device broke71.7%8.8%
Under-sensing61.5%2.5%
Device sensing problem30.7%5%
Low impedance30.7%6%
Pacing problem30.7%2.1%
Unstable capture threshold30.7%0.2%
Signal artifact/noise20.5%6.6%
Connection problema connection problem10.2%0.5%
Device damaged by another device10.2%0%
Intermittent capture10.2%0.6%

FDA's device problem codes as entered on the report; one report can carry several. Generic codes such as "no apparent adverse event" are left out.

Patient problems coded

Patient problem (FDA code)ReportsShare
Shock from patient lead(s)5413.5%
Twiddlers syndrome92.2%
Deaththe patient died; cause not stated by this term61.5%
Bacterial infectiona bacterial infection30.7%
Cardiac perforation30.7%
Pocket erosion30.7%
Falla fall20.5%
Hematomaa collection of blood under the skin or in tissue20.5%
Cardiac tamponade10.2%
Dyspneashortness of breath10.2%
Endocarditis10.2%
Failure of implant10.2%
Hypersensitivity/allergic reaction10.2%
Muscle stimulation10.2%
Painpain, site not specified10.2%

Patient problem codes are present mainly in reports filed since 2019 and are often blank.

In context

MeasureLinox Smart SD 60/16Product code NVYAll MAUDE reports
Reports401138,57826,136,888
Share of that pool—0.3%0%
Classified as death, per 1,000 reports15229
Classified as injury38.2%56.5%36.2%
Classified as malfunction60.3%41.2%62.3%
Filed by the manufacturer100%97.3%94.9%

Shares are of reports, not of devices in use. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data."

Other brands with product code NVY

BrandReportsLatest 12 monthsClassified as death
Durata Sts Optim Active Fixation Df-4 Connector27,8281,7843.9%
Endotak Reliance25,8972381.2%
Riata Active Fixation13,753961.8%
Sprint Quattro Secure MRI SureScan15,6061,9031.4%
Optisure Active Fixation Df-4 Connector6,5626234.3%
Endotak Reliance Sg8,2881,0830.5%
Sprint Quattro Secure24,23725.2%
Riata St Active Fixation5,416762.2%
Reliance 4-Front9,8522,0240.4%
Isoflex Optim Lead7,8894372%
Durata Sts Optim Active Fixation9,6813015.6%
Riata Passive Fixation4,318321.2%
Endotak Reliance G10,1151,0490.6%
Plexa ProMRI S 652,5212450.6%
Permanent Defibrillator Electrodes2,5242300.6%

Ordered by report count for navigation only. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data." FDA also states that "common products may have a higher number of adverse events due to the higher total number of people using the product."

Questions about Linox Smart SD 60/16 reports

How many FDA reports name Linox Smart SD 60/16?

401 medical device reports in the openFDA MAUDE release of 28 Sep 2026, covering reports received through August 2026; 22 in the latest 12 months.

What kinds of events are reported?

malfunction (60.3%), injury (38.2%) and death (1.5%). "Event type" is how the report was classified when filed: death, injury, malfunction or other.

What device problems are coded?

ambient noise problem (39.2%), high impedance (14.2%), inappropriate/inadequate shock/stimulation (13%), device dislodged or dislocated (12%) and fracture (10.7%). These are FDA's device problem codes as entered on the report.

Who files these reports?

manufacturer reports (100%). Manufacturers and user facilities are required to report; voluntary reports come from health professionals and the public.

Do these reports show that Linox Smart SD 60/16 was at fault?

No. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data." FDA adds that "a causal relationship cannot be established between product and reactions listed in a report."

How do I report a problem with a medical device?

Through FDA MedWatch (Form FDA 3500 for health professionals and consumers), or to the manufacturer. See the guide on how to report.

Where this comes from. Counts are built from the openFDA Device Adverse Event (MAUDE) bulk export released 28 Sep 2026, which holds reports FDA received through 31 Aug 2026. Brand, generic and manufacturer names are as written on the reports; product code names come from FDA's device classification. A report counts here when any device it lists carries this brand name after punctuation and capitalisation are normalised. No report narrative, lot number, patient detail or reporter identity is published. See the methodology and sources; FDA's record is authoritative, and corrections are handled within five working days.

Drug data (FAERS) through 30 Jun 2026; device data (MAUDE) through 31 Aug 2026. Not medical advice.