Ligaclip Mca Small Applier: medical device reports filed with FDA

557 reports name it, 2004–2026. Manufacturer given most often on reports: Ethicon Endo-Surgery. Product code GDO.

557
device reports naming the brand
0% of all MAUDE reports · about 25 a year
19
reports, 12 months to August 2026
29 in the 12 months before
97.3%
classified as malfunction
91.5% across the product code
0.2%
classified as death, as reported
1 reports · not verified by FDA

557 medical device reports received by FDA name the brand "Ligaclip Mca Small Applier" (clip implantable); the manufacturer given most often on reports is Ethicon Endo-Surgery; received from April 2004 to February 2026. Brand names are as the reporter or manufacturer wrote them, so one product can appear under several spellings.

19 reports arrived in the 12 months to August 2026, down 34% from 29 in the 12 months before. FDA releases MAUDE data monthly; reports can arrive months after an event, so the newest months grow in later releases. The event types recorded are malfunction (97.3%), injury (2.2%) and death (0.2%); across all applier, surgical, clip reports (product code GDO) death is recorded in 0.2% and malfunction in 91.5%. Event type is the reporter's classification of the report, not a verified outcome.

The device problems coded most often are failure to form staple (54.2%), replace (11%) and failure to fire (7.5%). The patient problems coded most often are hemorrhage/blood loss/bleeding, failure to anastomose and bleeding. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data."

Reports by month, five years

0918Sep 2021: 0Oct 2021: 0Nov 2021: 3Dec 2021: 32022Jan 2022: 0Feb 2022: 2Mar 2022: 1Apr 2022: 5May 2022: 1Jun 2022: 1Jul 2022: 2Aug 2022: 1Sep 2022: 1Oct 2022: 16Nov 2022: 1Dec 2022: 22023Jan 2023: 1Feb 2023: 0Mar 2023: 4Apr 2023: 3May 2023: 2Jun 2023: 11Jul 2023: 2Aug 2023: 18Sep 2023: 5Oct 2023: 13Nov 2023: 5Dec 2023: 122024Jan 2024: 2Feb 2024: 2Mar 2024: 1Apr 2024: 1May 2024: 4Jun 2024: 1Jul 2024: 1Aug 2024: 0Sep 2024: 4Oct 2024: 1Nov 2024: 0Dec 2024: 32025Jan 2025: 1Feb 2025: 2Mar 2025: 0Apr 2025: 0May 2025: 0Jun 2025: 9Jul 2025: 7Aug 2025: 2Sep 2025: 4Oct 2025: 3Nov 2025: 0Dec 2025: 22026Jan 2026: 3Feb 2026: 7Mar 2026: 0Apr 2026: 0May 2026: 0Jun 2026: 0Jul 2026: 0Aug 2026: 0

Reports by the month FDA received them. FDA releases MAUDE data monthly; reports can arrive months after an event, so the newest months grow in later releases.

By year received

038762004: 820042005: 222006: 42007: 4920072008: 342009: 342010: 1820102012: 152013: 112014: 520142016: 172017: 242018: 6020182019: 382020: 232021: 2620212022: 332023: 762024: 2020242025: 302026: 10

Event type and report source

Event type, as classified on the report

Death0.2%1
Injury2.2%12
Malfunction97.3%542
Other0%0
Not given0.4%2

Who filed the report

Manufacturer report99.8%556
Voluntary report0%0
User facility report0%0
Distributor report0%0
Not given0.2%1

Grey bar: all 16,592 reports carrying product code GDO. Event type is the filer's classification and is not verified by FDA.

Device problems coded

Device problem (FDA code)ReportsShareShare across product code
Failure to form staple30254.2%26.8%
Replace6111%31%
Failure to fire427.5%4.7%
Mechanical jam315.6%1.4%
Mechanics altered315.6%3.1%
Device operates differently than expectedthe device behaved unexpectedly285%3%
Failure to advance203.6%2.9%
Difficult to open or close183.2%2.3%
Sticking132.3%6.1%
Clips, scissored112%7.4%
Loose91.6%1.2%
Loose or intermittent connection91.6%0.3%
Misfire91.6%9.4%
Component falling81.4%2.2%
Mechanical problema mechanical problem81.4%1.4%
Delivered as unsterile product71.3%0.1%
Unintended ejection71.3%0.5%
Device issuea problem with the device50.9%3.1%
Firing problem50.9%0.3%
Breakthe device broke40.7%5%

FDA's device problem codes as entered on the report; one report can carry several. Generic codes such as "no apparent adverse event" are left out.

Patient problems coded

Patient problem (FDA code)ReportsShare
Hemorrhage/blood loss/bleeding437.7%
Failure to anastomose213.8%
Bleeding71.3%
Blood loss71.3%
Dural tear71.3%
Laceration(s)61.1%
Therapy/non-surgical treatment, additional40.7%
Tissue damage40.7%
Perforation of vessels30.5%
No patient involvement20.4%
Painpain, site not specified20.4%
Cardiac arrestthe heart stopped10.2%
Cut(s)10.2%
Dyspneashortness of breath10.2%
Foreign body in patientpart of a device left in the patient10.2%

Patient problem codes are present mainly in reports filed since 2019 and are often blank.

In context

MeasureLigaclip Mca Small ApplierProduct code GDOAll MAUDE reports
Reports55716,59226,136,888
Share of that pool—3.4%0%
Classified as death, per 1,000 reports229
Classified as injury2.2%6.5%36.2%
Classified as malfunction97.3%91.5%62.3%
Filed by the manufacturer99.8%93.3%94.9%

Shares are of reports, not of devices in use. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data."

Other brands with product code GDO

BrandReportsLatest 12 monthsClassified as death
Ligaclip Endoscopic Rotating Multiple Clip Applier4,35100.1%
Ligaclip Multiple Clip Applier1,06900.2%
Weck Hol Ml 5mm Endo Applier5783060%
Ligaclip Endoscopic Multiple Clip Applier56000%
Ligaclip Endoscopic Rotating Multiple Clip Applier 2082100%
Ligaclip Mca Med Applier51340.4%
Hol Ml 5mm Endo Applier45700%
Ligaclip Rotating Multiple Clip Applier46300%
Ligaclip Endo Rotating Mca2,2091090%
Ligaclip Mca Med Long Applier40890.2%
Ligaclip Clip Applier1,78700%
Ligaclip1,4253080%
Resolution Clip Device1,59600.3%
Ligaclip Mca Large Applier26830.4%
Ligaclip 20/20 Multiple Clip Applier25000%

Ordered by report count for navigation only. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data." FDA also states that "common products may have a higher number of adverse events due to the higher total number of people using the product."

Questions about Ligaclip Mca Small Applier reports

How many FDA reports name Ligaclip Mca Small Applier?

557 medical device reports in the openFDA MAUDE release of 28 Sep 2026, covering reports received through August 2026; 19 in the latest 12 months.

What kinds of events are reported?

malfunction (97.3%), injury (2.2%) and death (0.2%). "Event type" is how the report was classified when filed: death, injury, malfunction or other.

What device problems are coded?

failure to form staple (54.2%), replace (11%), failure to fire (7.5%), mechanical jam (5.6%) and mechanics altered (5.6%). These are FDA's device problem codes as entered on the report.

Who files these reports?

manufacturer reports (99.8%). Manufacturers and user facilities are required to report; voluntary reports come from health professionals and the public.

Do these reports show that Ligaclip Mca Small Applier was at fault?

No. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data." FDA adds that "a causal relationship cannot be established between product and reactions listed in a report."

How do I report a problem with a medical device?

Through FDA MedWatch (Form FDA 3500 for health professionals and consumers), or to the manufacturer. See the guide on how to report.

Where this comes from. Counts are built from the openFDA Device Adverse Event (MAUDE) bulk export released 28 Sep 2026, which holds reports FDA received through 31 Aug 2026. Brand, generic and manufacturer names are as written on the reports; product code names come from FDA's device classification. A report counts here when any device it lists carries this brand name after punctuation and capitalisation are normalised. No report narrative, lot number, patient detail or reporter identity is published. See the methodology and sources; FDA's record is authoritative, and corrections are handled within five working days.