Reported Reactions

Devices › Implant, endosseous, root-form

Device brand name · Endosseous dental implant

Legacy3 SBM Implant 3.7DX10L 3.5mmD Plat: medical device reports filed with FDA

240 reports name it, 2023–2026. Manufacturer given most often on reports: Implant Direct Sybron Manufact. Product code DZE.

240
device reports naming the brand
0% of all MAUDE reports · about 90 a year
111
reports, 12 months to August 2026
52 in the 12 months before
1.3%
classified as malfunction
0.8% across the product code
0%
classified as death, as reported
0 reports · not verified by FDA

FDA's MAUDE database holds 240 reports that name the brand "Legacy3 SBM Implant 3.7DX10L 3.5mmD Plat" (endosseous dental implant), received between November 2023 and August 2026; the manufacturer given most often on reports is Implant Direct Sybron Manufact. Spellings of one product vary from report to report.

111 reports arrived in the 12 months to August 2026, up 113% from 52 in the 12 months before. FDA releases MAUDE data monthly; reports can arrive months after an event, so the newest months grow in later releases. The event types recorded are injury (98.8%) and malfunction (1.3%); across all implant, endosseous, root-form reports (product code DZE) death is recorded in 0% and malfunction in 0.8%. Event type is the reporter's classification of the report, not a verified outcome.

The device problems coded most often are failure to osseointegrate (48.3%), loss of osseointegration (16.3%) and positioning failure (11.7%). The patient problems coded most often are inadequate osseointegration, failure of implant and abscess. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data."

Reports by month, five years

01632Sep 2021: 0Oct 2021: 0Nov 2021: 0Dec 2021: 02022Jan 2022: 0Feb 2022: 0Mar 2022: 0Apr 2022: 0May 2022: 0Jun 2022: 0Jul 2022: 0Aug 2022: 0Sep 2022: 0Oct 2022: 0Nov 2022: 0Dec 2022: 02023Jan 2023: 0Feb 2023: 0Mar 2023: 0Apr 2023: 0May 2023: 0Jun 2023: 0Jul 2023: 0Aug 2023: 0Sep 2023: 0Oct 2023: 0Nov 2023: 8Dec 2023: 12024Jan 2024: 7Feb 2024: 9Mar 2024: 7Apr 2024: 12May 2024: 3Jun 2024: 8Jul 2024: 2Aug 2024: 20Sep 2024: 12Oct 2024: 4Nov 2024: 4Dec 2024: 62025Jan 2025: 11Feb 2025: 5Mar 2025: 8Apr 2025: 2May 2025: 0Jun 2025: 0Jul 2025: 0Aug 2025: 0Sep 2025: 0Oct 2025: 16Nov 2025: 32Dec 2025: 112026Jan 2026: 16Feb 2026: 6Mar 2026: 7Apr 2026: 7May 2026: 3Jun 2026: 4Jul 2026: 6Aug 2026: 3

Reports by the month FDA received them. FDA releases MAUDE data monthly; reports can arrive months after an event, so the newest months grow in later releases.

By year received

047942023: 920232024: 9420242025: 8520252026: 522026

Event type and report source

Event type, as classified on the report

Death0%0
Injury98.8%237
Malfunction1.3%3
Other0%0
Not given0%0

Who filed the report

Manufacturer report100%240
Voluntary report0%0
User facility report0%0
Distributor report0%0
Not given0%0

Grey bar: all 3,924,241 reports carrying product code DZE. Event type is the filer's classification and is not verified by FDA.

Device problems coded

Device problem (FDA code)ReportsShareShare across product code
Failure to osseointegrate11648.3%62.8%
Loss of osseointegration3916.3%22.4%
Positioning failure2811.7%0.1%
Malposition of device104.2%0.1%
Premature separation104.2%0.1%
Fracturea broken bone93.8%1.6%
Osseointegration problem93.8%7.7%
Difficult to insertthe device was hard to insert52.1%0.4%
Component incompatible20.8%0%
Migrationthe device moved from where it was placed20.8%0.1%
Separation failure20.8%0.1%
Inadequacy of device shape and/or size10.4%0%
Insufficient device problem information10.4%0.2%
Labelling, instructions for use or training problem10.4%0%
Material deformation10.4%0.1%
Material discolored10.4%0%
Patient device interaction problem10.4%0.3%

FDA's device problem codes as entered on the report; one report can carry several. Generic codes such as "no apparent adverse event" are left out.

Patient problems coded

Patient problem (FDA code)ReportsShare
Inadequate osseointegration14058.3%
Failure of implant5322.1%
Abscessa collection of pus114.6%
Inflammationinflammation62.5%
Osteopenia/ osteoporosis52.1%
Granuloma31.3%
Bone fracture(s)20.8%
Implant pain20.8%
Appropriate clinical signs, symptoms and conditions term/code not available10.4%
Fibrosis10.4%
Hypersensitivity/allergic reaction10.4%
Painpain, site not specified10.4%

Patient problem codes are present mainly in reports filed since 2019 and are often blank.

In context

MeasureLegacy3 SBM Implant 3.7DX10L 3.5mmD PlatProduct code DZEAll MAUDE reports
Reports2403,924,24126,136,888
Share of that pool—0%0%
Classified as death, per 1,000 reports009
Classified as injury98.8%99.2%36.2%
Classified as malfunction1.3%0.8%62.3%
Filed by the manufacturer100%77.7%94.9%

Shares are of reports, not of devices in use. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data."

Other brands with product code DZE

BrandReportsLatest 12 monthsClassified as death
Biohorizons Dental Implant58,73200%
BioHorizons Inc.57,02025,5360%
NobelActive Internal RP 4.3x10mm49,0989,5280%
BLT ?4.1mm RC, SLA? 10mm, TiZr, Loxim45,6509,6770%
NobelParallel CC RP 4.3x10mm44,2699,3180%
BLT ?4.1mm RC, SLActive? 10mm, TiZr, NTP41,6727,5310%
Unknown Implant39,9671,4540%
NobelReplace CC RP 4.3x10mm35,9468,1660%
NobelReplace CC PMC RP 4.3x10mm34,4478,6900%
NobelActive Internal RP 4.3x11.5mm33,1175,7040%
BLT ?3.3mm NC, SLA? 10mm, TiZr, Loxim28,6485,6950%
BLT ?4.1mm RC, SLA? 10mm, Ti, Loxim26,7248,4810%
BLT ?3.3mm NC, SLActive? 10mm, TiZr, NTP26,5404,6800%
NobelActive Internal RP 4.3x13mm25,5563,7640%
BLT ?4.1mm RC, SLA? 8mm, TiZr, Loxim24,7725,9780%

Ordered by report count for navigation only. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data." FDA also states that "common products may have a higher number of adverse events due to the higher total number of people using the product."

Questions about Legacy3 SBM Implant 3.7DX10L 3.5mmD Plat reports

How many FDA reports name Legacy3 SBM Implant 3.7DX10L 3.5mmD Plat?

240 medical device reports in the openFDA MAUDE release of 28 Sep 2026, covering reports received through August 2026; 111 in the latest 12 months.

What kinds of events are reported?

injury (98.8%) and malfunction (1.3%). "Event type" is how the report was classified when filed: death, injury, malfunction or other.

What device problems are coded?

failure to osseointegrate (48.3%), loss of osseointegration (16.3%), positioning failure (11.7%), malposition of device (4.2%) and premature separation (4.2%). These are FDA's device problem codes as entered on the report.

Who files these reports?

manufacturer reports (100%). Manufacturers and user facilities are required to report; voluntary reports come from health professionals and the public.

Do these reports show that Legacy3 SBM Implant 3.7DX10L 3.5mmD Plat was at fault?

No. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data." FDA adds that "a causal relationship cannot be established between product and reactions listed in a report."

How do I report a problem with a medical device?

Through FDA MedWatch (Form FDA 3500 for health professionals and consumers), or to the manufacturer. See the guide on how to report.

Where this comes from. Counts are built from the openFDA Device Adverse Event (MAUDE) bulk export released 28 Sep 2026, which holds reports FDA received through 31 Aug 2026. Brand, generic and manufacturer names are as written on the reports; product code names come from FDA's device classification. A report counts here when any device it lists carries this brand name after punctuation and capitalisation are normalised. No report narrative, lot number, patient detail or reporter identity is published. See the methodology and sources; FDA's record is authoritative, and corrections are handled within five working days.

Drug data (FAERS) through 30 Jun 2026; device data (MAUDE) through 31 Aug 2026. Not medical advice.