Insignia I Ultra Dddro Is-1: medical device reports filed with FDA

323 reports name it, 2009–2010. Manufacturer given most often on reports: Guidant Crm Clonmel Ireland. Product code DXY.

323
device reports naming the brand
0% of all MAUDE reports · about 19 a year
0
reports, 12 months to August 2026
0 in the 12 months before
31.3%
classified as malfunction
41.2% across the product code
0%
classified as death, as reported
0 reports · not verified by FDA

FDA's MAUDE database holds 323 reports that name the brand "Insignia I Ultra Dddro Is-1" (implantable pulse generator), received between February 2009 and May 2010; the manufacturer given most often on reports is Guidant Crm Clonmel Ireland. Spellings of one product vary from report to report.

0 reports arrived in the 12 months to August 2026, and none in the 12 months before. FDA releases MAUDE data monthly; reports can arrive months after an event, so the newest months grow in later releases. The event types recorded are injury (68.4%), malfunction (31.3%) and other (0.3%); across all implantable pacemaker pulse-generator reports (product code DXY) death is recorded in 3.4% and malfunction in 41.2%. Event type is the reporter's classification of the report, not a verified outcome.

The device problems coded most often are low battery (16.7%), pacing problem (14.2%) and failure to capture (12.4%). The patient problems coded most often are syncope, other (for use when an appropriate patient code cannot be identified) and pocket erosion. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data."

Reports by month, five years

No report naming Insignia I Ultra Dddro Is-1 was received in the five years to August 2026; the latest was received in May 2010.

Event type and report source

Event type, as classified on the report

Death0%0
Injury68.4%221
Malfunction31.3%101
Other0.3%1
Not given0%0

Who filed the report

Manufacturer report100%323
Voluntary report0%0
User facility report0%0
Distributor report0%0
Not given0%0

Grey bar: all 57,832 reports carrying product code DXY. Event type is the filer's classification and is not verified by FDA.

Device problems coded

Device problem (FDA code)ReportsShareShare across product code
Low battery5416.7%5.3%
Pacing problem4614.2%6.4%
Failure to capture4012.4%6.3%
Premature discharge of battery3310.2%8.4%
Over-sensing319.6%5.4%
Normal309.3%2%
Malfunction237.1%1.9%
Noise195.9%1%
Pacing inadequately144.3%1.2%
Device sensing problem123.7%0.9%
Loss of threshold123.7%0.6%
Device operates differently than expectedthe device behaved unexpectedly103.1%1.8%
Alarm, error of warning72.2%0.5%
Failure to deliverthe device did not deliver the dose or item72.2%0.2%
High impedance72.2%3.8%
Difficult to interrogate61.9%3.1%
Sensing intermittently51.5%0.7%
Communication or transmission problemthe device could not communicate or transmit41.2%1.2%
Protective measures problem41.2%0.1%
Insufficient device problem information30.9%0.9%

FDA's device problem codes as entered on the report; one report can carry several. Generic codes such as "no apparent adverse event" are left out.

Patient problems coded

Patient problem (FDA code)ReportsShare
Syncopefainting3912.1%
Other (for use when an appropriate patient code cannot be identified)319.6%
Pocket erosion165%
Atrial fibrillationan irregular heart rhythm51.5%
Falla fall51.5%
Ventricular tachycardiaa fast rhythm from the lower heart chambers51.5%
Asystole41.2%
Bradycardiaslow heart rate41.2%
Ventricular fibrillationa chaotic rhythm from the lower heart chambers20.6%
Atrial tachycardia10.3%
Mitral valve replacement10.3%
Perforation10.3%

Patient problem codes are present mainly in reports filed since 2019 and are often blank.

In context

MeasureInsignia I Ultra Dddro Is-1Product code DXYAll MAUDE reports
Reports32357,83226,136,888
Share of that pool—0.6%0%
Classified as death, per 1,000 reports0349
Classified as injury68.4%54.4%36.2%
Classified as malfunction31.3%41.2%62.3%
Filed by the manufacturer100%96.6%94.9%

Shares are of reports, not of devices in use. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data."

Other brands with product code DXY

BrandReportsLatest 12 monthsClassified as death
Tendril Mri7,0764224.1%
Medtronic Lead2,3513289.5%
Carelink Program W/Telemetry C1,68100%
Carelink15,005180%
Assurity Mri18,9952,0351.8%
Insignia Plus94009.1%
Insignia Ultra79705.4%
Meta Dddr53200.4%
Enpulse606310.4%
Medtronic ICD40410523.8%
Insignia Entra374010.2%
Anthem Rf37204.3%
Tempo7211550.7%
Medtronic2,953174.4%
Symphony1,1631331.6%

Ordered by report count for navigation only. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data." FDA also states that "common products may have a higher number of adverse events due to the higher total number of people using the product."

Questions about Insignia I Ultra Dddro Is-1 reports

How many FDA reports name Insignia I Ultra Dddro Is-1?

323 medical device reports in the openFDA MAUDE release of 28 Sep 2026, covering reports received through August 2026; 0 in the latest 12 months.

What kinds of events are reported?

injury (68.4%), malfunction (31.3%) and other (0.3%). "Event type" is how the report was classified when filed: death, injury, malfunction or other.

What device problems are coded?

low battery (16.7%), pacing problem (14.2%), failure to capture (12.4%), premature discharge of battery (10.2%) and over-sensing (9.6%). These are FDA's device problem codes as entered on the report.

Who files these reports?

manufacturer reports (100%). Manufacturers and user facilities are required to report; voluntary reports come from health professionals and the public.

Do these reports show that Insignia I Ultra Dddro Is-1 was at fault?

No. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data." FDA adds that "a causal relationship cannot be established between product and reactions listed in a report."

How do I report a problem with a medical device?

Through FDA MedWatch (Form FDA 3500 for health professionals and consumers), or to the manufacturer. See the guide on how to report.

Where this comes from. Counts are built from the openFDA Device Adverse Event (MAUDE) bulk export released 28 Sep 2026, which holds reports FDA received through 31 Aug 2026. Brand, generic and manufacturer names are as written on the reports; product code names come from FDA's device classification. A report counts here when any device it lists carries this brand name after punctuation and capitalisation are normalised. No report narrative, lot number, patient detail or reporter identity is published. See the methodology and sources; FDA's record is authoritative, and corrections are handled within five working days.