Reported Reactions

Devices › Drill, surgical, ent (electric or pneumatic) including handpiece

Device brand name · Drill surgical ent electric or pneumatic i

ENT Mr8: medical device reports filed with FDA

622 reports name it, 2025–2026. Manufacturer given most often on reports: Mdt Powered Surgical Solutions. Product code ERL.

622
device reports naming the brand
0% of all MAUDE reports · about 442 a year
538
reports, 12 months to August 2026
84 in the 12 months before
99%
classified as malfunction
98.9% across the product code
0%
classified as death, as reported
0 reports · not verified by FDA

622 medical device reports received by FDA name the brand "ENT Mr8" (drill surgical ent electric or pneumatic i); the manufacturer given most often on reports is Mdt Powered Surgical Solutions; received from February 2025 to August 2026. Brand names are as the reporter or manufacturer wrote them, so one product can appear under several spellings.

538 reports arrived in the 12 months to August 2026, up 540% from 84 in the 12 months before. FDA releases MAUDE data monthly; reports can arrive months after an event, so the newest months grow in later releases. The event types recorded are malfunction (99%) and injury (1%); across all drill, surgical, ent (electric or pneumatic) including handpiece reports (product code ERL) death is recorded in 0% and malfunction in 98.9%. Event type is the reporter's classification of the report, not a verified outcome.

The device problems coded most often are overheating of device (18.8%), detachment of device or device component (15.6%) and difficult to insert (13.3%). The patient problems coded most often are device embedded in tissue or plaque, brain injury and burn(s). FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data."

Reports by month, five years

098195Sep 2021: 0Oct 2021: 0Nov 2021: 0Dec 2021: 02022Jan 2022: 0Feb 2022: 0Mar 2022: 0Apr 2022: 0May 2022: 0Jun 2022: 0Jul 2022: 0Aug 2022: 0Sep 2022: 0Oct 2022: 0Nov 2022: 0Dec 2022: 02023Jan 2023: 0Feb 2023: 0Mar 2023: 0Apr 2023: 0May 2023: 0Jun 2023: 0Jul 2023: 0Aug 2023: 0Sep 2023: 0Oct 2023: 0Nov 2023: 0Dec 2023: 02024Jan 2024: 0Feb 2024: 0Mar 2024: 0Apr 2024: 0May 2024: 0Jun 2024: 0Jul 2024: 0Aug 2024: 0Sep 2024: 0Oct 2024: 0Nov 2024: 0Dec 2024: 02025Jan 2025: 0Feb 2025: 3Mar 2025: 32Apr 2025: 26May 2025: 7Jun 2025: 4Jul 2025: 8Aug 2025: 4Sep 2025: 7Oct 2025: 12Nov 2025: 6Dec 2025: 42026Jan 2026: 2Feb 2026: 2Mar 2026: 17Apr 2026: 46May 2026: 38Jun 2026: 90Jul 2026: 195Aug 2026: 119

Reports by the month FDA received them. FDA releases MAUDE data monthly; reports can arrive months after an event, so the newest months grow in later releases.

Event type and report source

Event type, as classified on the report

Death0%0
Injury1%6
Malfunction99%616
Other0%0
Not given0%0

Who filed the report

Manufacturer report100%622
Voluntary report0%0
User facility report0%0
Distributor report0%0
Not given0%0

Grey bar: all 29,931 reports carrying product code ERL. Event type is the filer's classification and is not verified by FDA.

Device problems coded

Device problem (FDA code)ReportsShareShare across product code
Overheating of device11718.8%43.4%
Detachment of device or device componentpart of the device came off9715.6%4%
Difficult to insertthe device was hard to insert8313.3%0.3%
Naturally worn6210%0.5%
Vibration426.8%2.4%
Loss of powerthe device lost power274.3%0.3%
Noise, audible243.9%2.9%
Physical resistance/sticking193.1%0.2%
Difficult to removethe device was hard to remove162.6%0%
Fracturea broken bone61%0.7%
Corrodedthe device corroded30.5%0%
Loose or intermittent connection30.5%0.2%
Breakthe device broke20.3%5.2%
Device displays incorrect message20.3%4.3%
Device remains activated20.3%3.7%
Insufficient device problem information20.3%0.1%
Material deformation20.3%0%
Material puncture/hole20.3%0%

FDA's device problem codes as entered on the report; one report can carry several. Generic codes such as "no apparent adverse event" are left out.

Patient problems coded

Patient problem (FDA code)ReportsShare
Device embedded in tissue or plaque20.3%
Brain injury10.2%
Burn(s)a burn10.2%
Dural tear10.2%
Nerve damage10.2%
Paresis10.2%
Perforation10.2%

Patient problem codes are present mainly in reports filed since 2019 and are often blank.

In context

MeasureENT Mr8Product code ERLAll MAUDE reports
Reports62229,93126,136,888
Share of that pool—2.1%0%
Classified as death, per 1,000 reports009
Classified as injury1%0.9%36.2%
Classified as malfunction99%98.9%62.3%
Filed by the manufacturer100%99.5%94.9%

Shares are of reports, not of devices in use. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data."

Other brands with product code ERL

BrandReportsLatest 12 monthsClassified as death
Xmax Motor4,44700%
Remb Electric Sagittal Saw1,69340%
Core Impaction Drill3,91300%
S2 Drill844790%
Motor Assembly Xmax893140%
Ipc Handpiece - Xps Straightshot M57111240%
Remb Electric Micro Drill66090%
Xps Handpiece - Visao649120%
Ipc Handpiece - Xps Straightshot M4607450%
Pi Drive Plus Motor56400%
Micro Sagittal Saw1,39500%
Core Universal Driver67900%
Pi Drive Motor47700%
Core Sumex Drill52200%
Straight Irrigating Attachment454340%

Ordered by report count for navigation only. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data." FDA also states that "common products may have a higher number of adverse events due to the higher total number of people using the product."

Questions about ENT Mr8 reports

How many FDA reports name ENT Mr8?

622 medical device reports in the openFDA MAUDE release of 28 Sep 2026, covering reports received through August 2026; 538 in the latest 12 months.

What kinds of events are reported?

malfunction (99%) and injury (1%). "Event type" is how the report was classified when filed: death, injury, malfunction or other.

What device problems are coded?

overheating of device (18.8%), detachment of device or device component (15.6%), difficult to insert (13.3%), naturally worn (10%) and vibration (6.8%). These are FDA's device problem codes as entered on the report.

Who files these reports?

manufacturer reports (100%). Manufacturers and user facilities are required to report; voluntary reports come from health professionals and the public.

Do these reports show that ENT Mr8 was at fault?

No. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data." FDA adds that "a causal relationship cannot be established between product and reactions listed in a report."

How do I report a problem with a medical device?

Through FDA MedWatch (Form FDA 3500 for health professionals and consumers), or to the manufacturer. See the guide on how to report.

Where this comes from. Counts are built from the openFDA Device Adverse Event (MAUDE) bulk export released 28 Sep 2026, which holds reports FDA received through 31 Aug 2026. Brand, generic and manufacturer names are as written on the reports; product code names come from FDA's device classification. A report counts here when any device it lists carries this brand name after punctuation and capitalisation are normalised. No report narrative, lot number, patient detail or reporter identity is published. See the methodology and sources; FDA's record is authoritative, and corrections are handled within five working days.

Drug data (FAERS) through 30 Jun 2026; device data (MAUDE) through 31 Aug 2026. Not medical advice.