Endurant: medical device reports filed with FDA

1,861 reports name it, 2011–2019. Manufacturer given most often on reports: Medtronic Ireland. Product code MIH.

1,861
device reports naming the brand
0% of all MAUDE reports · about 124 a year
0
reports, 12 months to August 2026
0 in the 12 months before
12.4%
classified as malfunction
14.8% across the product code
14.7%
classified as death, as reported
274 reports · not verified by FDA

1,861 medical device reports received by FDA name the brand "Endurant" (system endovascular graft aortic aneurysm treatment); the manufacturer given most often on reports is Medtronic Ireland; received from July 2011 to September 2019. Brand names are as the reporter or manufacturer wrote them, so one product can appear under several spellings.

0 reports arrived in the 12 months to August 2026, and none in the 12 months before. FDA releases MAUDE data monthly; reports can arrive months after an event, so the newest months grow in later releases. The event types recorded are injury (72.9%), death (14.7%) and malfunction (12.4%); across all system, endovascular graft, aortic aneurysm treatment reports (product code MIH) death is recorded in 9.8% and malfunction in 14.8%. Event type is the reporter's classification of the report, not a verified outcome.

The device problems coded most often are leak/splash (47.3%), occlusion within device (21.1%) and migration or expulsion of device (5.1%). The patient problems coded most often are occlusion, injury and death. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data."

Reports by month, five years

No report naming Endurant was received in the five years to August 2026; the latest was received in September 2019.

By year received

03226432011: 320112012: 4320122013: 64320132014: 60020142015: 31920152016: 5620162017: 5120172018: 2920182019: 1172019

Event type and report source

Event type, as classified on the report

Death14.7%274
Injury72.9%1,356
Malfunction12.4%231
Other0%0
Not given0%0

Who filed the report

Manufacturer report99.9%1,859
Voluntary report0%0
User facility report0%0
Distributor report0%0
Not given0.1%2

Grey bar: all 72,039 reports carrying product code MIH. Event type is the filer's classification and is not verified by FDA.

Device problems coded

Device problem (FDA code)ReportsShareShare across product code
Leak/splashthe device leaked88047.3%33.8%
Occlusion within devicethe device blocked39221.1%5.4%
Migration or expulsion of device945.1%6.1%
Inaccurate delivery613.3%1.3%
Malposition of device492.6%3.9%
Kinkedthe tube or line kinked452.4%1.7%
Difficult to removethe device was hard to remove361.9%2.6%
Insufficient device problem information321.7%6.4%
Breakthe device broke301.6%1.3%
Difficult to position221.2%1.5%
Activation, positioning or separation problem201.1%1.7%
Folded120.6%0.3%
Difficult or delayed positioning110.6%1.4%
Fracturea broken bone90.5%0.7%
Material deformation90.5%1.4%
Failure to adhere or bond70.4%1.8%
Difficult to insertthe device was hard to insert60.3%1%
Inadequacy of device shape and/or size50.3%0.5%
Separation failure50.3%0.1%
Device damaged by another device40.2%0.4%

FDA's device problem codes as entered on the report; one report can carry several. Generic codes such as "no apparent adverse event" are left out.

Patient problems coded

Patient problem (FDA code)ReportsShare
Occlusion32817.6%
Injurya physical injury29916.1%
Deaththe patient died; cause not stated by this term25913.9%
Rupturethe device burst1488%
Hemorrhage/blood loss/bleeding1347.2%
Aneurysm834.5%
Ischemia814.4%
Renal failurekidney failure653.5%
Myocardial infarctionheart attack522.8%
Blood loss472.5%
Painpain, site not specified462.5%
Perforation of vessels351.9%
Hematomaa collection of blood under the skin or in tissue321.7%
Stroke/cva291.6%
Fistula281.5%

Patient problem codes are present mainly in reports filed since 2019 and are often blank.

In context

MeasureEndurantProduct code MIHAll MAUDE reports
Reports1,86172,03926,136,888
Share of that pool—2.6%0%
Classified as death, per 1,000 reports147989
Classified as injury72.9%74.9%36.2%
Classified as malfunction12.4%14.8%62.3%
Filed by the manufacturer99.9%99%94.9%

Shares are of reports, not of devices in use. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data."

Other brands with product code MIH

BrandReportsLatest 12 monthsClassified as death
GORE EXCLUDER AAA Endoprosthesis9,5906334.8%
Afx3,584305%
Gore Tag Thoracic Endoprosthesis2,829414.7%
Endurant Iis Bifurcated Stent Graft1,70612111.6%
Valiant Captivia - FF1,5329515.1%
GORE TAG Conformable Thoracic Stent Graft with ACTIVE CONTROL System1,4743117.7%
Endurant Stent Graft1,4715610%
Afx21,2631236.4%
Medtronic Aneurx Bifurcated Stent Graft Flexible1,26309.7%
Zenith Flex AAA Endovascular Graft Bifurcated Main Body1,172156.1%
Valiant Navion1,1494017.4%
Ancure Endograft System1,12605.1%
Endurant Abdominal Stent Graft System997012.9%
Afx System88208.4%
Ovation IX870453.1%

Ordered by report count for navigation only. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data." FDA also states that "common products may have a higher number of adverse events due to the higher total number of people using the product."

Questions about Endurant reports

How many FDA reports name Endurant?

1,861 medical device reports in the openFDA MAUDE release of 28 Sep 2026, covering reports received through August 2026; 0 in the latest 12 months.

What kinds of events are reported?

injury (72.9%), death (14.7%) and malfunction (12.4%). "Event type" is how the report was classified when filed: death, injury, malfunction or other.

What device problems are coded?

leak/splash (47.3%), occlusion within device (21.1%), migration or expulsion of device (5.1%), inaccurate delivery (3.3%) and malposition of device (2.6%). These are FDA's device problem codes as entered on the report.

Who files these reports?

manufacturer reports (99.9%). Manufacturers and user facilities are required to report; voluntary reports come from health professionals and the public.

Do these reports show that Endurant was at fault?

No. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data." FDA adds that "a causal relationship cannot be established between product and reactions listed in a report."

How do I report a problem with a medical device?

Through FDA MedWatch (Form FDA 3500 for health professionals and consumers), or to the manufacturer. See the guide on how to report.

Where this comes from. Counts are built from the openFDA Device Adverse Event (MAUDE) bulk export released 28 Sep 2026, which holds reports FDA received through 31 Aug 2026. Brand, generic and manufacturer names are as written on the reports; product code names come from FDA's device classification. A report counts here when any device it lists carries this brand name after punctuation and capitalisation are normalised. No report narrative, lot number, patient detail or reporter identity is published. See the methodology and sources; FDA's record is authoritative, and corrections are handled within five working days.

Drug data (FAERS) through 30 Jun 2026; device data (MAUDE) through 31 Aug 2026. Not medical advice.