Reported Reactions

Devices › Pump, infusion

Device brand name · Pump infusion

Colleague P1 7: medical device reports filed with FDA

186 reports name it, 2011–2011. Manufacturer given most often on reports: Baxter Healthcare - Singapore. Product code FRN.

186
device reports naming the brand
0% of all MAUDE reports · about 12 a year
0
reports, 12 months to August 2026
0 in the 12 months before
99.5%
classified as malfunction
98.5% across the product code
0%
classified as death, as reported
0 reports · not verified by FDA

186 medical device reports received by FDA name the brand "Colleague P1 7" (pump infusion); the manufacturer given most often on reports is Baxter Healthcare - Singapore; received from May 2011 to August 2011. Brand names are as the reporter or manufacturer wrote them, so one product can appear under several spellings.

0 reports arrived in the 12 months to August 2026, and none in the 12 months before. FDA releases MAUDE data monthly; reports can arrive months after an event, so the newest months grow in later releases. The event types recorded are malfunction (99.5%) and injury (0.5%); across all pump, infusion reports (product code FRN) death is recorded in 0.1% and malfunction in 98.5%. Event type is the reporter's classification of the report, not a verified outcome.

The device problems coded most often are device displays incorrect message (43.5%), device operates differently than expected (15.1%) and break (9.1%). The patient problems coded most often are no patient involvement, hyperglycemia and overdose. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data."

Reports by month, five years

No report naming Colleague P1 7 was received in the five years to August 2026; the latest was received in August 2011.

Event type and report source

Event type, as classified on the report

Death0%0
Injury0.5%1
Malfunction99.5%185
Other0%0
Not given0%0

Who filed the report

Manufacturer report100%186
Voluntary report0%0
User facility report0%0
Distributor report0%0
Not given0%0

Grey bar: all 1,831,109 reports carrying product code FRN. Event type is the filer's classification and is not verified by FDA.

Device problems coded

Device problem (FDA code)ReportsShareShare across product code
Device displays incorrect message8143.5%9.3%
Device operates differently than expectedthe device behaved unexpectedly2815.1%0.9%
Breakthe device broke179.1%8.5%
Battery problema problem with the battery158.1%1.2%
Failure to deliverthe device did not deliver the dose or item84.3%0.8%
No display/image63.2%0.7%
Device alarm system52.7%2.8%
Image display error/artifact52.7%0%
Mechanical problema mechanical problem52.7%0.3%
Poor quality image52.7%0%
Air leak42.2%0.6%
Display or visual feedback problem42.2%1.1%
Charging problem31.6%0.2%
No audible alarm31.6%0.2%
Computer software problema software problem21.1%0.6%
Defective component21.1%0.1%
Electrical /electronic property probleman electrical or electronic problem21.1%0.8%
Erratic or intermittent display21.1%0%
Excess flow or over-infusion21.1%1.2%
Failure to charge21.1%0%

FDA's device problem codes as entered on the report; one report can carry several. Generic codes such as "no apparent adverse event" are left out.

Patient problems coded

Patient problem (FDA code)ReportsShare
No patient involvement7841.9%
Hyperglycemiahigh blood sugar10.5%
Overdosea dose above the recommended amount10.5%
Underdoseless than the intended dose10.5%

Patient problem codes are present mainly in reports filed since 2019 and are often blank.

In context

MeasureColleague P1 7Product code FRNAll MAUDE reports
Reports1861,831,10926,136,888
Share of that pool—0%0%
Classified as death, per 1,000 reports019
Classified as injury0.5%1.3%36.2%
Classified as malfunction99.5%98.5%62.3%
Filed by the manufacturer100%99.1%94.9%

Shares are of reports, not of devices in use. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data."

Other brands with product code FRN

BrandReportsLatest 12 monthsClassified as death
Alaris Pump Module684,52200%
Alaris System422,50133,6920%
8100 Alaris Pump Module163,62000%
Spectrum Infusion Pump147,363150%
8015 Alaris System Pc Unit54,16200%
Alaris System Pc Unit24,06600%
8110 Alaris Syringe Pump22,43400%
Colleague21,76300%
Reservoir 3ML MMT-332A19,9142,0080.4%
Reservoir 3ml16,40700.8%
Flogard15,66800%
Colleague Volumetric Infusion Pump13,67800.1%
Colleague Pre P1 713,10300%
CADD-Solis VIP Ambulatory Infusion Pump11,7213,4710.1%
Intermate8,261470%

Ordered by report count for navigation only. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data." FDA also states that "common products may have a higher number of adverse events due to the higher total number of people using the product."

Questions about Colleague P1 7 reports

How many FDA reports name Colleague P1 7?

186 medical device reports in the openFDA MAUDE release of 28 Sep 2026, covering reports received through August 2026; 0 in the latest 12 months.

What kinds of events are reported?

malfunction (99.5%) and injury (0.5%). "Event type" is how the report was classified when filed: death, injury, malfunction or other.

What device problems are coded?

device displays incorrect message (43.5%), device operates differently than expected (15.1%), break (9.1%), battery problem (8.1%) and failure to deliver (4.3%). These are FDA's device problem codes as entered on the report.

Who files these reports?

manufacturer reports (100%). Manufacturers and user facilities are required to report; voluntary reports come from health professionals and the public.

Do these reports show that Colleague P1 7 was at fault?

No. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data." FDA adds that "a causal relationship cannot be established between product and reactions listed in a report."

How do I report a problem with a medical device?

Through FDA MedWatch (Form FDA 3500 for health professionals and consumers), or to the manufacturer. See the guide on how to report.

Where this comes from. Counts are built from the openFDA Device Adverse Event (MAUDE) bulk export released 28 Sep 2026, which holds reports FDA received through 31 Aug 2026. Brand, generic and manufacturer names are as written on the reports; product code names come from FDA's device classification. A report counts here when any device it lists carries this brand name after punctuation and capitalisation are normalised. No report narrative, lot number, patient detail or reporter identity is published. See the methodology and sources; FDA's record is authoritative, and corrections are handled within five working days.

Drug data (FAERS) through 30 Jun 2026; device data (MAUDE) through 31 Aug 2026. Not medical advice.