Reported Reactions

Devices › Stapler, surgical

Device brand name · Disposable surgical stapler

Auto Suture Premium Plus Ceea 31mm: medical device reports filed with FDA

357 reports name it, 1996–2001. Manufacturer given most often on reports: United States Surgical. Product code GAG.

357
device reports naming the brand
0% of all MAUDE reports · about 12 a year
0
reports, 12 months to August 2026
0 in the 12 months before
73.9%
classified as malfunction
72.9% across the product code
0.3%
classified as death, as reported
1 reports · not verified by FDA

357 medical device reports received by FDA name the brand "Auto Suture Premium Plus Ceea 31mm" (disposable surgical stapler); the manufacturer given most often on reports is United States Surgical; received from November 1996 to August 2001. Brand names are as the reporter or manufacturer wrote them, so one product can appear under several spellings.

0 reports arrived in the 12 months to August 2026, and none in the 12 months before. FDA releases MAUDE data monthly; reports can arrive months after an event, so the newest months grow in later releases. The event types recorded are malfunction (73.9%), injury (25.8%) and death (0.3%); across all stapler, surgical reports (product code GAG) death is recorded in 1% and malfunction in 72.9%. Event type is the reporter's classification of the report, not a verified outcome.

The device problems coded most often are device issue (49.3%), replace (41.5%) and mechanical problem (25.8%). The patient problems coded most often are failure to anastomose, tissue damage and surgical procedure, additional. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data."

Reports by month, five years

No report naming Auto Suture Premium Plus Ceea 31mm was received in the five years to August 2026; the latest was received in August 2001.

By year received

0521041996: 319961997: 3219971998: 6619981999: 9219992000: 10420002001: 602001

Event type and report source

Event type, as classified on the report

Death0.3%1
Injury25.8%92
Malfunction73.9%264
Other0%0
Not given0%0

Who filed the report

Manufacturer report99.7%356
Voluntary report0%0
User facility report0%0
Distributor report0%0
Not given0.3%1

Grey bar: all 26,848 reports carrying product code GAG. Event type is the filer's classification and is not verified by FDA.

Device problems coded

Device problem (FDA code)ReportsShareShare across product code
Device issuea problem with the device17649.3%15.9%
Replace14841.5%35.2%
Mechanical problema mechanical problem9225.8%1.3%
Failure to cut5114.3%3.6%
Failure to form staple4713.2%27.4%
Difficult to removethe device was hard to remove4211.8%5.7%
Sticking3810.6%10.9%
Misfire339.2%8.9%
Device, removal of (non-implant)257%0.9%
Detachment of device component164.5%1.8%
Component missing143.9%3%
Component(s), broken133.6%1.1%
Disengaged133.6%0.7%
Failure to adhere or bond113.1%1.2%
Failure to fire113.1%8.9%
Close, difficult to72%0.7%
Breakthe device broke41.1%1.9%
Material separation41.1%0.5%
Defective component30.8%0.1%
Air leak20.6%0.1%

FDA's device problem codes as entered on the report; one report can carry several. Generic codes such as "no apparent adverse event" are left out.

Patient problems coded

Patient problem (FDA code)ReportsShare
Failure to anastomose15844.3%
Tissue damage6718.8%
Surgical procedure, additional4913.7%
Surgery, prolonged349.5%
Surgical procedure185%
Colostomy154.2%
Laparotomy82.2%
Surgical procedure, repeated72%
Dural tear61.7%
Foreign body, removal of51.4%
Therapy/non-surgical treatment, additional51.4%
Other (for use when an appropriate patient code cannot be identified)41.1%
Bleeding30.8%
Deaththe patient died; cause not stated by this term20.6%
Fistula20.6%

Patient problem codes are present mainly in reports filed since 2019 and are often blank.

In context

MeasureAuto Suture Premium Plus Ceea 31mmProduct code GAGAll MAUDE reports
Reports35726,84826,136,888
Share of that pool—1.3%0%
Classified as death, per 1,000 reports3109
Classified as injury25.8%25.1%36.2%
Classified as malfunction73.9%72.9%62.3%
Filed by the manufacturer99.7%91.8%94.9%

Shares are of reports, not of devices in use. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data."

Other brands with product code GAG

BrandReportsLatest 12 monthsClassified as death
Endopath Endoscopic Multifeed Stapler1,70600%
Proximate Linear Cutter1,77611.3%
Eea4,9225420.8%
Gia4,8994040.9%
Proximate I L S Intraluminal Stapler70902%
Proximate Reloadable Linear Stapler1,02501.4%
Endo Gia Universal 12mm Single Use Inst1,07701.8%
Auto Suture Roticulator 55-4 845100.2%
Proximate Access 55 Articulating Linear Stapler39800.5%
Ta1,5411421%
Auto Suture Roticulator 55 Poly - 20035300%
Auto Suture Roticulator 55-3 531400.6%
Endopath Endoscopic Linear Cutter32200%
Echelon1,3525843.2%
Proximate Linear Stapler57901.2%

Ordered by report count for navigation only. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data." FDA also states that "common products may have a higher number of adverse events due to the higher total number of people using the product."

Questions about Auto Suture Premium Plus Ceea 31mm reports

How many FDA reports name Auto Suture Premium Plus Ceea 31mm?

357 medical device reports in the openFDA MAUDE release of 28 Sep 2026, covering reports received through August 2026; 0 in the latest 12 months.

What kinds of events are reported?

malfunction (73.9%), injury (25.8%) and death (0.3%). "Event type" is how the report was classified when filed: death, injury, malfunction or other.

What device problems are coded?

device issue (49.3%), replace (41.5%), mechanical problem (25.8%), failure to cut (14.3%) and failure to form staple (13.2%). These are FDA's device problem codes as entered on the report.

Who files these reports?

manufacturer reports (99.7%). Manufacturers and user facilities are required to report; voluntary reports come from health professionals and the public.

Do these reports show that Auto Suture Premium Plus Ceea 31mm was at fault?

No. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data." FDA adds that "a causal relationship cannot be established between product and reactions listed in a report."

How do I report a problem with a medical device?

Through FDA MedWatch (Form FDA 3500 for health professionals and consumers), or to the manufacturer. See the guide on how to report.

Where this comes from. Counts are built from the openFDA Device Adverse Event (MAUDE) bulk export released 28 Sep 2026, which holds reports FDA received through 31 Aug 2026. Brand, generic and manufacturer names are as written on the reports; product code names come from FDA's device classification. A report counts here when any device it lists carries this brand name after punctuation and capitalisation are normalised. No report narrative, lot number, patient detail or reporter identity is published. See the methodology and sources; FDA's record is authoritative, and corrections are handled within five working days.

Drug data (FAERS) through 30 Jun 2026; device data (MAUDE) through 31 Aug 2026. Not medical advice.