1,852 reports name it, 2021–2026. Manufacturer given most often on reports: Dentsply Implants Manufacturing. Product code DZE.

1,852
device reports naming the brand
0% of all MAUDE reports · about 343 a year
493
reports, 12 months to August 2026
357 in the 12 months before
0%
classified as malfunction
0.8% across the product code
0%
classified as death, as reported
0 reports · not verified by FDA

1,852 medical device reports received by FDA name the brand "AstraTech Impl EV 4.2S 8mm OS" (implant endosseous root-form); the manufacturer given most often on reports is Dentsply Implants Manufacturing; received from February 2021 to August 2026. Brand names are as the reporter or manufacturer wrote them, so one product can appear under several spellings.

493 reports arrived in the 12 months to August 2026, up 38% from 357 in the 12 months before. FDA releases MAUDE data monthly; reports can arrive months after an event, so the newest months grow in later releases. The event types recorded are injury (100%); across all implant, endosseous, root-form reports (product code DZE) death is recorded in 0% and malfunction in 0.8%. Event type is the reporter's classification of the report, not a verified outcome.

The device problems coded most often are failure to osseointegrate (68%), loss of osseointegration (18%) and osseointegration problem (12.4%). The patient problems coded most often are failure of implant, inflammation and osteolysis. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data."

Reports by month, five years

04385Sep 2021: 16Oct 2021: 8Nov 2021: 15Dec 2021: 162022Jan 2022: 23Feb 2022: 27Mar 2022: 18Apr 2022: 17May 2022: 18Jun 2022: 27Jul 2022: 13Aug 2022: 21Sep 2022: 17Oct 2022: 12Nov 2022: 32Dec 2022: 232023Jan 2023: 29Feb 2023: 32Mar 2023: 29Apr 2023: 17May 2023: 32Jun 2023: 37Jul 2023: 33Aug 2023: 28Sep 2023: 16Oct 2023: 33Nov 2023: 26Dec 2023: 222024Jan 2024: 46Feb 2024: 19Mar 2024: 28Apr 2024: 39May 2024: 35Jun 2024: 31Jul 2024: 29Aug 2024: 16Sep 2024: 24Oct 2024: 32Nov 2024: 17Dec 2024: 182025Jan 2025: 26Feb 2025: 18Mar 2025: 55Apr 2025: 17May 2025: 26Jun 2025: 41Jul 2025: 46Aug 2025: 37Sep 2025: 20Oct 2025: 30Nov 2025: 30Dec 2025: 392026Jan 2026: 40Feb 2026: 38Mar 2026: 44Apr 2026: 53May 2026: 23Jun 2026: 58Jul 2026: 85Aug 2026: 33

Reports by the month FDA received them. FDA releases MAUDE data monthly; reports can arrive months after an event, so the newest months grow in later releases.

By year received

01933852021: 17720212022: 24820222023: 33420232024: 33420242025: 38520252026: 3742026

Event type and report source

Event type, as classified on the report

Death0%0
Injury100%1,852
Malfunction0%0
Other0%0
Not given0%0

Who filed the report

Manufacturer report100%1,852
Voluntary report0%0
User facility report0%0
Distributor report0%0
Not given0%0

Grey bar: all 3,924,241 reports carrying product code DZE. Event type is the filer's classification and is not verified by FDA.

Device problems coded

Device problem (FDA code)ReportsShareShare across product code
Failure to osseointegrate1,25968%62.8%
Loss of osseointegration33418%22.4%
Osseointegration problem22912.4%7.7%
Fracturea broken bone251.3%1.6%
Malposition of device100.5%0.1%
Difficult to insertthe device was hard to insert50.3%0.4%
Migration or expulsion of device30.2%0%
Crackthe device cracked20.1%0%
Separation failure20.1%0.1%
Insufficient device problem information10.1%0.2%
Material deformation10.1%0.1%
Positioning failure10.1%0.1%

FDA's device problem codes as entered on the report; one report can carry several. Generic codes such as "no apparent adverse event" are left out.

Patient problems coded

Patient problem (FDA code)ReportsShare
Failure of implant1,84999.8%
Inflammationinflammation1849.9%
Osteolysis1467.9%
Pocket erosion884.8%
Implant pain140.8%
Sinus perforation50.3%
Painpain, site not specified40.2%
Deformity/ disfigurement20.1%
Discomfortdiscomfort20.1%
Erosion20.1%
Swelling/ edema20.1%
Fistula10.1%
Inadequate osseointegration10.1%
Numbnessnumbness10.1%
Osteopenia/ osteoporosis10.1%

Patient problem codes are present mainly in reports filed since 2019 and are often blank.

In context

MeasureAstraTech Impl EV 4.2S 8mm OSProduct code DZEAll MAUDE reports
Reports1,8523,924,24126,136,888
Share of that pool—0%0%
Classified as death, per 1,000 reports009
Classified as injury100%99.2%36.2%
Classified as malfunction0%0.8%62.3%
Filed by the manufacturer100%77.7%94.9%

Shares are of reports, not of devices in use. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data."

Other brands with product code DZE

BrandReportsLatest 12 monthsClassified as death
Biohorizons Dental Implant58,73200%
BioHorizons Inc.57,02025,5360%
NobelActive Internal RP 4.3x10mm49,0989,5280%
BLT ?4.1mm RC, SLA? 10mm, TiZr, Loxim45,6509,6770%
NobelParallel CC RP 4.3x10mm44,2699,3180%
BLT ?4.1mm RC, SLActive? 10mm, TiZr, NTP41,6727,5310%
Unknown Implant39,9671,4540%
NobelReplace CC RP 4.3x10mm35,9468,1660%
NobelReplace CC PMC RP 4.3x10mm34,4478,6900%
NobelActive Internal RP 4.3x11.5mm33,1175,7040%
BLT ?3.3mm NC, SLA? 10mm, TiZr, Loxim28,6485,6950%
BLT ?4.1mm RC, SLA? 10mm, Ti, Loxim26,7248,4810%
BLT ?3.3mm NC, SLActive? 10mm, TiZr, NTP26,5404,6800%
NobelActive Internal RP 4.3x13mm25,5563,7640%
BLT ?4.1mm RC, SLA? 8mm, TiZr, Loxim24,7725,9780%

Ordered by report count for navigation only. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data." FDA also states that "common products may have a higher number of adverse events due to the higher total number of people using the product."

Questions about AstraTech Impl EV 4.2S 8mm OS reports

How many FDA reports name AstraTech Impl EV 4.2S 8mm OS?

1,852 medical device reports in the openFDA MAUDE release of 28 Sep 2026, covering reports received through August 2026; 493 in the latest 12 months.

What kinds of events are reported?

injury (100%). "Event type" is how the report was classified when filed: death, injury, malfunction or other.

What device problems are coded?

failure to osseointegrate (68%), loss of osseointegration (18%), osseointegration problem (12.4%), fracture (1.3%) and malposition of device (0.5%). These are FDA's device problem codes as entered on the report.

Who files these reports?

manufacturer reports (100%). Manufacturers and user facilities are required to report; voluntary reports come from health professionals and the public.

Do these reports show that AstraTech Impl EV 4.2S 8mm OS was at fault?

No. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data." FDA adds that "a causal relationship cannot be established between product and reactions listed in a report."

How do I report a problem with a medical device?

Through FDA MedWatch (Form FDA 3500 for health professionals and consumers), or to the manufacturer. See the guide on how to report.

Where this comes from. Counts are built from the openFDA Device Adverse Event (MAUDE) bulk export released 28 Sep 2026, which holds reports FDA received through 31 Aug 2026. Brand, generic and manufacturer names are as written on the reports; product code names come from FDA's device classification. A report counts here when any device it lists carries this brand name after punctuation and capitalisation are normalised. No report narrative, lot number, patient detail or reporter identity is published. See the methodology and sources; FDA's record is authoritative, and corrections are handled within five working days.

Drug data (FAERS) through 30 Jun 2026; device data (MAUDE) through 31 Aug 2026. Not medical advice.