Reported Reactions

Devices › Analyzer, chemistry (photometric, discrete), for clinical use

Device brand name · Analyzer chemistry photometric discrete for clinical use

Architect I1000sr: medical device reports filed with FDA

239 reports name it, 2020–2025. Manufacturer given most often on reports: Abbott Laboratories. Product code JJE.

239
device reports naming the brand
0% of all MAUDE reports · about 42 a year
0
reports, 12 months to August 2026
17 in the 12 months before
98.7%
classified as malfunction
95.5% across the product code
0%
classified as death, as reported
0 reports · not verified by FDA

239 medical device reports received by FDA name the brand "Architect I1000sr" (analyzer chemistry photometric discrete for clinical use); the manufacturer given most often on reports is Abbott Laboratories; received from October 2020 to February 2025. Brand names are as the reporter or manufacturer wrote them, so one product can appear under several spellings.

0 reports arrived in the 12 months to August 2026, against 17 in the 12 months before. FDA releases MAUDE data monthly; reports can arrive months after an event, so the newest months grow in later releases. The event types recorded are malfunction (98.7%) and injury (1.3%); across all analyzer, chemistry (photometric, discrete), for clinical use reports (product code JJE) death is recorded in 0% and malfunction in 95.5%. Event type is the reporter's classification of the report, not a verified outcome.

The device problems coded most often are high test results (44.8%), false positive result (15.9%) and low test results (14.6%). The patient problems coded most often are exposure to body fluids, cardiac enzyme elevation and chest pain. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data."

Reports by month, five years

01019Sep 2021: 2Oct 2021: 7Nov 2021: 19Dec 2021: 42022Jan 2022: 2Feb 2022: 2Mar 2022: 1Apr 2022: 4May 2022: 8Jun 2022: 5Jul 2022: 2Aug 2022: 7Sep 2022: 5Oct 2022: 4Nov 2022: 3Dec 2022: 32023Jan 2023: 9Feb 2023: 5Mar 2023: 10Apr 2023: 3May 2023: 4Jun 2023: 2Jul 2023: 4Aug 2023: 7Sep 2023: 11Oct 2023: 5Nov 2023: 5Dec 2023: 22024Jan 2024: 5Feb 2024: 4Mar 2024: 5Apr 2024: 3May 2024: 6Jun 2024: 3Jul 2024: 5Aug 2024: 3Sep 2024: 1Oct 2024: 3Nov 2024: 4Dec 2024: 22025Jan 2025: 5Feb 2025: 2Mar 2025: 0Apr 2025: 0May 2025: 0Jun 2025: 0Jul 2025: 0Aug 2025: 0Sep 2025: 0Oct 2025: 0Nov 2025: 0Dec 2025: 02026Jan 2026: 0Feb 2026: 0Mar 2026: 0Apr 2026: 0May 2026: 0Jun 2026: 0Jul 2026: 0Aug 2026: 0

Reports by the month FDA received them. FDA releases MAUDE data monthly; reports can arrive months after an event, so the newest months grow in later releases.

By year received

034672020: 820202021: 6720212022: 4620222023: 6720232024: 4420242025: 72025

Event type and report source

Event type, as classified on the report

Death0%0
Injury1.3%3
Malfunction98.7%236
Other0%0
Not given0%0

Who filed the report

Manufacturer report99.6%238
Voluntary report0.4%1
User facility report0%0
Distributor report0%0
Not given0%0

Grey bar: all 79,280 reports carrying product code JJE. Event type is the filer's classification and is not verified by FDA.

Device problems coded

Device problem (FDA code)ReportsShareShare across product code
High test results10744.8%27.1%
False positive result3815.9%2.6%
Low test results3514.6%24.5%
Incorrect, inadequate or imprecise result or readings177.1%8.9%
Smoking72.9%0.9%
False negative result62.5%1.1%
Leak/splashthe device leaked62.5%3.1%
Thermal decomposition of device52.1%0.4%
Sparking31.3%0.2%
Unable to obtain readings20.8%0.2%
Unintended electrical shock20.8%0%
Computer software problema software problem10.4%0.4%
Electrical shorting10.4%0%
Fire10.4%0.1%
Fluid/blood leak10.4%3.6%
Mechanical problema mechanical problem10.4%2.4%
Melted10.4%0.1%

FDA's device problem codes as entered on the report; one report can carry several. Generic codes such as "no apparent adverse event" are left out.

Patient problems coded

Patient problem (FDA code)ReportsShare
Exposure to body fluids20.8%
Cardiac enzyme elevation10.4%
Chest painchest pain10.4%
Conjunctivitispink eye10.4%
Electric shockan electric shock10.4%
Eye injury10.4%
Eye paineye pain10.4%
No patient involvement10.4%
Red eye(s)10.4%

Patient problem codes are present mainly in reports filed since 2019 and are often blank.

In context

MeasureArchitect I1000srProduct code JJEAll MAUDE reports
Reports23979,28026,136,888
Share of that pool—0.3%0%
Classified as death, per 1,000 reports009
Classified as injury1.3%1.5%36.2%
Classified as malfunction98.7%95.5%62.3%
Filed by the manufacturer99.6%99.6%94.9%

Shares are of reports, not of devices in use. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data."

Other brands with product code JJE

BrandReportsLatest 12 monthsClassified as death
Access 2 Immunoassay System4,71900%
Unicel Dxi 800 Access Immunoassay System3,13300%
cobas 6000 c501 module2,7321940.1%
COBAS 6000 C (501) Module2,1691290%
UniCel DxC 600i SYNCHRON Access Clinical System2,975130%
Unicel Dxc 800 Synchron System2,23200%
Architect I2000sr Analyzer1,78500.1%
cobas c 503 analytical unit1,4155410%
Alinity Ci-Series Level Sensor Bulk Solution1,33900%
Alinity c Processing Module1,3113020.1%
Cobas 8000 C 702 Module1,28300%
Cobas E 411 Immunoassay Analyzer1,15800.1%
AU5800 Clinical Chemistry Analyzer1,151690%
Architect Reaction Vessel1,12400%
Dimension Vista 15001,10240%

Ordered by report count for navigation only. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data." FDA also states that "common products may have a higher number of adverse events due to the higher total number of people using the product."

Questions about Architect I1000sr reports

How many FDA reports name Architect I1000sr?

239 medical device reports in the openFDA MAUDE release of 28 Sep 2026, covering reports received through August 2026; 0 in the latest 12 months.

What kinds of events are reported?

malfunction (98.7%) and injury (1.3%). "Event type" is how the report was classified when filed: death, injury, malfunction or other.

What device problems are coded?

high test results (44.8%), false positive result (15.9%), low test results (14.6%), incorrect, inadequate or imprecise result or readings (7.1%) and smoking (2.9%). These are FDA's device problem codes as entered on the report.

Who files these reports?

manufacturer reports (99.6%) and voluntary reports (0.4%). Manufacturers and user facilities are required to report; voluntary reports come from health professionals and the public.

Do these reports show that Architect I1000sr was at fault?

No. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data." FDA adds that "a causal relationship cannot be established between product and reactions listed in a report."

How do I report a problem with a medical device?

Through FDA MedWatch (Form FDA 3500 for health professionals and consumers), or to the manufacturer. See the guide on how to report.

Where this comes from. Counts are built from the openFDA Device Adverse Event (MAUDE) bulk export released 28 Sep 2026, which holds reports FDA received through 31 Aug 2026. Brand, generic and manufacturer names are as written on the reports; product code names come from FDA's device classification. A report counts here when any device it lists carries this brand name after punctuation and capitalisation are normalised. No report narrative, lot number, patient detail or reporter identity is published. See the methodology and sources; FDA's record is authoritative, and corrections are handled within five working days.

Drug data (FAERS) through 30 Jun 2026; device data (MAUDE) through 31 Aug 2026. Not medical advice.