Reported Reactions

Devices › System, endovascular graft, aortic aneurysm treatment

Device brand name · Mih

Aneurx Aaadvantage Stent Graft System: medical device reports filed with FDA

521 reports name it, 2006–2011. Manufacturer given most often on reports: Medtronic Cardiovascular. Product code MIH.

521
device reports naming the brand
0% of all MAUDE reports · about 26 a year
0
reports, 12 months to August 2026
0 in the 12 months before
7.9%
classified as malfunction
14.8% across the product code
13.6%
classified as death, as reported
71 reports · not verified by FDA

521 medical device reports received by FDA name the brand "Aneurx Aaadvantage Stent Graft System" (mih); the manufacturer given most often on reports is Medtronic Cardiovascular; received from May 2006 to October 2011. Brand names are as the reporter or manufacturer wrote them, so one product can appear under several spellings.

0 reports arrived in the 12 months to August 2026, and none in the 12 months before. FDA releases MAUDE data monthly; reports can arrive months after an event, so the newest months grow in later releases. The event types recorded are injury (78.5%), death (13.6%) and malfunction (7.9%); across all system, endovascular graft, aortic aneurysm treatment reports (product code MIH) death is recorded in 9.8% and malfunction in 14.8%. Event type is the reporter's classification of the report, not a verified outcome.

The device problems coded most often are leak/splash (39.3%), migration or expulsion of device (22.6%) and occlusion within device (16.3%). The patient problems coded most often are other (for use when an appropriate patient code cannot be identified), surgical procedure, additional and surgical procedure. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data."

Reports by month, five years

No report naming Aneurx Aaadvantage Stent Graft System was received in the five years to August 2026; the latest was received in October 2011.

By year received

0861722006: 6820062007: 17220072008: 4720082009: 8120092010: 8620102011: 672011

Event type and report source

Event type, as classified on the report

Death13.6%71
Injury78.5%409
Malfunction7.9%41
Other0%0
Not given0%0

Who filed the report

Manufacturer report99.8%520
Voluntary report0%0
User facility report0%0
Distributor report0%0
Not given0.2%1

Grey bar: all 72,039 reports carrying product code MIH. Event type is the filer's classification and is not verified by FDA.

Device problems coded

Device problem (FDA code)ReportsShareShare across product code
Leak/splashthe device leaked20539.3%33.8%
Migration or expulsion of device11822.6%6.1%
Occlusion within devicethe device blocked8516.3%5.4%
Device remains implanted6612.7%3.6%
Kinkedthe tube or line kinked407.7%1.7%
Inaccurate delivery356.7%1.3%
Implant, removal of265%0.4%
Dissection234.4%0.1%
Difficult to position224.2%1.5%
Replace224.2%1.1%
Material perforation203.8%0.1%
Device, removal of (non-implant)112.1%0.4%
Difficult to insertthe device was hard to insert91.7%1%
Failure to advance91.7%1.1%
Difficult or delayed positioning61.2%1.4%
Positioning failure61.2%0.7%
Other (for use when an appropriate device code cannot be identified)51%1.4%
Sticking51%0.8%
Difficult to removethe device was hard to remove40.8%2.6%
Inadequacy of device shape and/or size40.8%0.5%

FDA's device problem codes as entered on the report; one report can carry several. Generic codes such as "no apparent adverse event" are left out.

Patient problems coded

Patient problem (FDA code)ReportsShare
Other (for use when an appropriate patient code cannot be identified)20639.5%
Surgical procedure, additional9418%
Surgical procedure8616.5%
Deaththe patient died; cause not stated by this term6512.5%
Rupturethe device burst5210%
Hemorrhage/blood loss/bleeding377.1%
Therapy/non-surgical treatment, additional316%
Aneurysm254.8%
Occlusion214%
Intimal dissection142.7%
Hospitalization required122.3%
Renal failurekidney failure122.3%
Aortic dissection112.1%
Bleeding112.1%
Blood loss81.5%

Patient problem codes are present mainly in reports filed since 2019 and are often blank.

In context

MeasureAneurx Aaadvantage Stent Graft SystemProduct code MIHAll MAUDE reports
Reports52172,03926,136,888
Share of that pool—0.7%0%
Classified as death, per 1,000 reports136989
Classified as injury78.5%74.9%36.2%
Classified as malfunction7.9%14.8%62.3%
Filed by the manufacturer99.8%99%94.9%

Shares are of reports, not of devices in use. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data."

Other brands with product code MIH

BrandReportsLatest 12 monthsClassified as death
GORE EXCLUDER AAA Endoprosthesis9,5906334.8%
Afx3,584305%
Gore Tag Thoracic Endoprosthesis2,829414.7%
Endurant1,861014.7%
Endurant Iis Bifurcated Stent Graft1,70612111.6%
Valiant Captivia - FF1,5329515.1%
GORE TAG Conformable Thoracic Stent Graft with ACTIVE CONTROL System1,4743117.7%
Endurant Stent Graft1,4715610%
Afx21,2631236.4%
Medtronic Aneurx Bifurcated Stent Graft Flexible1,26309.7%
Zenith Flex AAA Endovascular Graft Bifurcated Main Body1,172156.1%
Valiant Navion1,1494017.4%
Ancure Endograft System1,12605.1%
Endurant Abdominal Stent Graft System997012.9%
Afx System88208.4%

Ordered by report count for navigation only. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data." FDA also states that "common products may have a higher number of adverse events due to the higher total number of people using the product."

Questions about Aneurx Aaadvantage Stent Graft System reports

How many FDA reports name Aneurx Aaadvantage Stent Graft System?

521 medical device reports in the openFDA MAUDE release of 28 Sep 2026, covering reports received through August 2026; 0 in the latest 12 months.

What kinds of events are reported?

injury (78.5%), death (13.6%) and malfunction (7.9%). "Event type" is how the report was classified when filed: death, injury, malfunction or other.

What device problems are coded?

leak/splash (39.3%), migration or expulsion of device (22.6%), occlusion within device (16.3%), device remains implanted (12.7%) and kinked (7.7%). These are FDA's device problem codes as entered on the report.

Who files these reports?

manufacturer reports (99.8%). Manufacturers and user facilities are required to report; voluntary reports come from health professionals and the public.

Do these reports show that Aneurx Aaadvantage Stent Graft System was at fault?

No. FDA states that "MDR data alone cannot be used to establish rates of events, evaluate a change in event rates over time or compare event rates between devices. The number of reports cannot be interpreted or used in isolation to reach conclusions about the existence, severity, or frequency of problems associated with devices." It adds that the reporting system "has limitations, including the potential submission of incomplete, inaccurate, untimely, unverified, or biased data." FDA adds that "a causal relationship cannot be established between product and reactions listed in a report."

How do I report a problem with a medical device?

Through FDA MedWatch (Form FDA 3500 for health professionals and consumers), or to the manufacturer. See the guide on how to report.

Where this comes from. Counts are built from the openFDA Device Adverse Event (MAUDE) bulk export released 28 Sep 2026, which holds reports FDA received through 31 Aug 2026. Brand, generic and manufacturer names are as written on the reports; product code names come from FDA's device classification. A report counts here when any device it lists carries this brand name after punctuation and capitalisation are normalised. No report narrative, lot number, patient detail or reporter identity is published. See the methodology and sources; FDA's record is authoritative, and corrections are handled within five working days.